Sequential spectrophotometric determination of chromium(III) and chromium(VI) using flow injection analysis
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
26/05/2014
26/05/2014
01/12/1985
|
Resumo |
A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure. |
Formato |
197-199 |
Identificador |
http://dx.doi.org/10.1039/AN9851000197 The Analyst, v. 110, n. 2, p. 197-199, 1985. 0003-2654 http://hdl.handle.net/11449/63730 10.1039/AN9851000197 2-s2.0-2542529820 |
Idioma(s) |
eng |
Relação |
The Analyst |
Direitos |
closedAccess |
Palavras-Chave | #Chromium determination #Chromium speciation #Flow injection analysis #Spectrophotometry |
Tipo |
info:eu-repo/semantics/article |