129 resultados para Validation of test results
Resumo:
It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.
Resumo:
Based on the lack of electromyographic researches on sport and programmes of physical conditioning, we can say that it is necessary to reexamine some exercises routinely used in the programmes of physical conditioning. Thus, the trapezius and serratus anterior muscles were studied electromyographically so that we could evaluate the validity in some ways of execution of the frontal-lateral cross, dumbbells exercises for the development of these muscles. We analyzed 24 male volunteers, 18 to 25 years old, using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the execution of the exercise it was used a supine bench, a straight board and two bars of 40 cm made of light wood. The results showed that TS acted preferentially in standing modality and in the inclined supine modality, however with activity levels that do not justify its inclusion in physical fitness programmes.
Resumo:
The trapezius and serratus anterior muscles were studied in four modalities of rowing exercises executed with two grips, middle and closed, in comparison with the four different modalities of frontal-lateral cross, dumbbells exercise. It was used 24 male volunteers, 18 to 25 years old using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The results showed that TS acted in a higher significant way in all the modalities of rowing than in the supine lateral raise, inclined supine lateral raise and reverse supine lateral raise, dumbbells exercises, and demonstrated no standing frontal-lateral cross, dumbbells. The SI acted more significantly difference among all the execution modalities of rowing and the inclined supine lateral raise, dumbbells exercises than in all the rowing exercises; even though the activity levels do not make us suggest them as an excellent group of exercises for the development of this muscle.
Resumo:
Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
Because the lack of specialized textbooks, the select of basic exercises for physical conditioning programmes is based on empirical knowledge. This fact led the authors to propose the study on electromyographic activity of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with closed grip in three different modalities. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a long bar made of light wood was used. TS acted significantly in the three different modalities, that is, upright, sitting and bent over, while SI acted preferentially in upright and sitting rowing exercises, justifying their inclusion as basic exercises in physical conditioning programmes.
Resumo:
Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.
Resumo:
The action potential level for shoulder muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) determined by four different modalities of execution of rowing exercises, each one with two different grips, was recorded. These were compared with the action potential level determined for the same muscles by four different modalities of execution of the frontal-lateral cross, dumbbells exercises. Twenty-four male volunteers were examined using a 2 channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. The statistic analysis showed significant (p<0,05) superiority for all the frontal-lateral cross, dumbbells exercises in comparison to all rowing exercises for the PMC, for the DA this generalized supremacy was not observed.
Resumo:
A simple, sensitive and accurate spectrophotometric method was developed for the assay of gatifloxacin in raw material and tablets. Validation of the method yielded good results concerning range, linearity, precision and accuracy. The absorbance was measured at 287 nm for gatifloxacin tablet solutions. The linearity range was found to be 4.0-14.0 μg/mL for gatifloxacin. It was also found that the excipients in the commercial tablets did not interfere with the method.
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.
Resumo:
It was analized the deltoid muscle anterior portion and the pectoralis major clavicular portion in 24 male volunteers using a two-channel electromyograph TECA TE 4, and Hewllet Packard surface electrodes, in 4 modalities of military press exercises with open grip. The results showed high inactivity for PMC in almost all the modalities while DA developed very high levels of action potentials in all the modalities assessed.
Resumo:
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.
Resumo:
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Resumo:
Background and Objective: Simple Measure of the Impact of Lupus Erythematosus in Youngsters (SMILEY) is a health-related quality of life (HRQOL) assessment tool for pediatric systemic lupus erythematosus (SLE), which has been translated into Portuguese for Brazil. We are reporting preliminary data on cross-cultural validation and reliability of SMILEY in Portuguese (Brazil). Methods: In this multi-center cross-sectional study, Brazilian children and adolescents 5-18 years of age with SLE and parents participated. Children and parents completed child and parent reports of Portuguese SMILEY and Portuguese Pediatric Quality of Life Inventory (PedsQLTM) Generic and Rheumatology modules. Parents also completed the Childhood Health Assessment Questionnaire (CHAQ). Physicians completed the SLE disease activity index (SLEDAI), Physician's Global Assessment of disease activity (PGA) and Systemic Lupus Erythematosus International Collaborating Clinics ACR Damage Index (SDI). Results: 99 subjects (84 girls) were enrolled; 93 children and 97 parents filled out the SMILEY scale. Subjects found SMILEY relevant and easy to understand and completed SMILEY in 5-15 minutes. Brazilian SMILEY was found to have good psychometric properties (validity and reliability), and the child-parent agreement was moderate. Conclusion: SMILEY may eventually be used routinely as a research/clinical tool in Brazil. It may be also adapted for other Portuguese-speaking nations offering critical information regarding the effect of SLE on HRQOL for children with SLE. © The Author(s), 2012.
Resumo:
Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.