104 resultados para Orthogonal polynomials on the unit circle
Resumo:
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.
Resumo:
A positive measure ψ defined on [a,b] such that its moments μn=∫a btndψ(t) exist for n=0,±1,±2,⋯, is called a strong positive measure on [a,b]. If 0≤athen the sequence of (monic) polynomials {Qn}, defined by ∫a bt-n+sQn(t)dψ(t)=0, s=0,1,⋯,n-1, is known to exist. We refer to these polynomials as the L-orthogonal polynomials with respect to the strong positive measure ψ. The purpose of this manuscript is to consider some properties of the kernel polynomials associated with these L-orthogonal polynomials. As applications, we consider the quadrature rules associated with these kernel polynomials. Associated eigenvalue problems and numerical evaluation of the nodes and weights of such quadrature rules are also considered. © 2010 IMACS. Published by Elsevier B.V. All rights reserved.
Resumo:
In this paper we analyze the location of the zeros of polynomials orthogonal with respect to the inner product where α >-1, N ≥ 0, and j ∈ N. In particular, we focus our attention on their interlacing properties with respect to the zeros of Laguerre polynomials as well as on the monotonicity of each individual zero in terms of the mass N. Finally, we give necessary and sufficient conditions in terms of N in order for the least zero of any Laguerre-Sobolev-type orthogonal polynomial to be negative. © 2011 American Mathematical Society.
Resumo:
The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid/60s and silanized. The dentin was treated with37% phosphoric acid/15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement/RC curing type(dual-and photocured), light-curing unit (halogen light/QTH and LED), and storage conditions (dry and storage/150 days + 12,000 cycles/thermocycling). All blocks were stored in distilled water (37°C/24h) and sectioned (n = 10): G1-QTH + RC Photo, G2-QTH + RC Dual, G3-LED + RC Photo, G4-LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1-12.95 (6.40)ab; G2-12.02 (4.59)ab; G3-13.09 (5.62)ab; G4-15.96 (6.32)a; G5-6.22 (5.90)c; G6-9.48 (5.99)bc; G7-12.78 (11.30)ab; and G8-8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength betweenceramic cemented to dentin when the photocured cement was used, and only after aging (LED>QTH). There was no difference between the effects of dual-and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.
Resumo:
Given a strongly regular Hankel matrix, and its associated sequence of moments which defines a quasi-definite moment linear functional, we study the perturbation of a fixed moment, i.e., a perturbation of one antidiagonal of the Hankel matrix. We define a linear functional whose action results in such a perturbation and establish necessary and sufficient conditions in order to preserve the quasi-definite character. A relation between the corresponding sequences of orthogonal polynomials is obtained, as well as the asymptotic behavior of their zeros. We also study the invariance of the Laguerre-Hahn class of linear functionals under such perturbation, and determine its relation with the so-called canonical linear spectral transformations. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective. To estimate the prevalence of bacteria isolated in samples from the hands of school-age children at a hospitalization unit. Methodology. In 2009, strains were cultured from the hands of 90 school-age children at the pediatric hospitalization unit of Hospital Estadual Bauru (São Paulo, Brazil). After culture of the samples, the isolated bacteria were identified. Results. In 98% of the samples taken from the children, bacteria were isolated. Coagulase-negative Staphilococcus was isolated in 64% of the samples, followed by Staphilococcus aureus (5%) and Pseudomonas aeruginosa (1%). Conclusion. In most of the samples from the children’s hands, bacteria were isolated. Therefore, educative actions about hygiene habits in- and outside the hospital environment should be reinforced, aimed at children and their companions.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This article concerns the free vibration of a single-degree-of-freedom (SDOF) system with three types of nonlinear damping. One system considered is where the spring and the damper are connected to the mass so that they are orthogonal, and the vibration is in the direction of the spring. It is shown that, provided the displacement is small, this system behaves in a similar way to the conventional SDOF system with cubic damping, in which the spring and the damper are connected so they act in the same direction. For completeness, these systems are compared with a conventional SDOF system with quadratic damping. By transforming all the equations of motion of the systems so that the damping force is proportional to the product of a displacement dependent term and velocity, then all the systems can be directly compared. It is seen that the system with cubic damping is worse than that with quadratic damping for the attenuation of free vibration. [DOI: 10.1115/1.4005010]
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The left ventricular mass (LVM) measurement is of major importance for renal patients, as ventricular hypertrophy is an important prognostic index. The echo-cardiogram of the ventricular mass is larger before than it is after hemodialysis, which can confuse data interpretation. The aim of this work is to study the influence of alterations in fluid volume on the variations in measurements of ventricular mass observed during the course of a hemodialysis. Sixteen patients with chronic renal insufficiency in hemodialysis were evaluated at the Dialysis Unit of the University Hospital-UNESP, Botucatu, São Paulo State. The left ventricular mass was calculated from echocardiograms taken before and after hemodialysis and simultaneous ultra-filtration (12 patients: UF GROUP) and before and after hemodialysis isovolemic phase with sequential ultra-filtration (10 patients: ISO GROUP). Six of these patients were submitted to measurements of left ventricular mass before and after hemodialysis in both isovolemic and simultaneous ultra-filtration procedures. In the UF group, there was significant reduction in the following parameters before and after dialysis: diastolic diameter from 54.0 +/- 6.0 mm to 45.6 +/- 7.6 mm; left ventricular mass from 342 +/- 114 g to 265 +/- 117 g; and its respective index (IMVE) from 214 +/- 68 g/m(2) to 168 +/- 71 g/m(2). The ISO group showed no statistically significant variation. The behavior of the variables of six patients submitted to both observations confirm these results. In conclusion, the variations in echocardiogram measurements of the left ventricular mass relating to hemodialysis appear to be induced by alterations of the volemic condition.
Resumo:
An experiment was carried out at the Research and Development Unit of Brotas aiming at evaluating dietary calcium level and limestone particle size on the production performance of commercial (Hy-Line Brown) layers in the second lay cycle. Experiment duration was 112 days. A total number of 288 hens, with 83 weeks of age in the beginning of the experiment, were used in a completely randomized experimental design in a factorial arrangement of 2x3, with two calcium levels (3.5 and 4.0%) and three limestone particle size compositions: 100% fine limestone (FL), 30% coarse limestone (CL) + 70% fine limestone (FL), and 50% (CL) + 50% (FL), with six replicates of eight birds each. Egg weight (g), egg production (%), egg mass (%), feed intake (g), feed conversion ratio (kg/dz and kg/kg), mortality (%), and egg loss (%) were evaluated. The analysis of variance did not detect significant differences (p>0.05) among treatments on any of the evaluated performance parameters. It was concluded that the tested calcium levels and limestone particle composition did not influence the performance of semi-heavy layers in second production cycle.
Resumo:
The experiment was carried out in the experimental poultry house of the Research and Development Unit of Brotas of Agência Paulista de Tecnologia dos Agronegócios do Centro-Oeste, SP, Brazil. The objective of the study was to evaluate the performance of Japanese quails submitted to forced molting aiming at optimizing the use of the same quail flock by promoting a second laying cycle. A total number of 400 67-day-old Japanese quails in lay, previously submitted to 14 days of forced molting, was distributed in a completely randomized experimental design into five treatments (T1= not submitted to forced molting, T2= 03 days of fasting + fed ad libitum, T3= 01 days of fasting + 13 days of feed restriction, T4= 02 days of fasting + 12 days of feed restriction, and T5= 03 days of fasting + 11 days of feed restriction. Feeds were contained equal nutrient levels, and were formulated according to NRC (1994) recommendations. There were significant differences among the studied treatments. Although the treatment of 3 days of fasting followed by ad libitum feeding resulted in lower egg weight, it promoted better lay percentage, egg mass, and feed conversion ratios (FCR/dz and FCR/kg). on the other hand, 3 days of fasting followed by restricted feeding resulted in higher feed intake and worse feed conversion ratios (FCR/dz and FCR/kg). When birds were not submitted to forced molting, they presented lower lay percentage and egg mass.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)