78 resultados para tiroxina total
Resumo:
The aim of this study was to obtain an isoflavone-supplemented soy yogurt, fermented with Enterococcus faecium CRL 183 and Lactobacillus helveticus ssp jugurti, with suitable sensory properties and to assess the effects of the final product on blood lipids in hypercholesterolemic rats. Four isoflavone supplementation procedures were tested, in which the isoflavone was added at these stages: (1) before heat-treatment; (2) after heating and before fermentation; (3) after fermentation and (4) in the okara (by-product of soy milk) flour stirred into the fermented product when consumed. The products were subjected to a test of sensory acceptability. To assess their potential hypocholesterolemic properties in vivo, four groups of rats were used: control (C), hypercholesterolemic (H), hypercholesterolemic plus fermented product (HF) and hypercholesterolemic plus isoflavone-supplemented fermented product (HFI). Hypercholesterolemia was induced in rats of groups H, HF and HFI by feeding them on a commercial rat chow to which cholesterol and cholic acid had been added. Total, HDL and non-HDL cholesterol and triglycerides were measured in the blood of the rats. No significant sensorial differences were detected among the samples of soy yogurt supplemented with isoflavones at various processing stages. Rats fed a fermented soy product enriched with isoflavones (HFI group) had significantly (P < 0.05) less serum total cholesterol (15.5%) compared with rats fed a hypercholesterolemic diet (H group). Non-HDL cholesterol was less (P < 0.05) in rats fed a fermented soy product enriched or not with isoflavones (27.4 and 23.2%) compared to H group. The HDL-C and triglyceride concentrations did not differ significantly among the groups. It was possible to obtain an isoflavone-supplemented soy yogurt with satisfactory sensory characteristics. The resulting supplemented soy yogurt was capable of producing a lipid-lowering effect in hypercholesterolemic rats, relative to the animals that did not consume this product.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A introdução do assunto qualidade, segundo as necessidades de mercado abre espaço para a discussão da qualidade como necessidade pessoal, e também para a formação do cidadão/profissional, além de introduzir assuntos específicos de administração de empresas. Dessa forma, foi oferecida uma disciplina optativa para os alunos do Instituto de Química do Campus de Araraquara, abordando o tema Qualidade e foi denominada Gestão da Qualidade por três anos seguidos. da avaliação geral do curso extraiu-se que ele deveria ser realizado sempre, que o tema é atual e relevante e contribui para a formação profissional/pessoal. Com relação ao comprometimento com o curso de graduação, cerca de metade dos alunos assume o seu comprometimento com os estudos e os restantes dizem estarem somente envolvidos. Conclui-se, portanto que o curso atingiu os seus objetivos propostos, introduziu os principais conceitos de qualidade segundo as normas da qualidade da série ISO 9000 e suscitou a discussão da formação do aluno/profissional/cidadão.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work presents a methodology for iron determination in fuel ethanol using a modified carbon paste electrode with 1.10 fenantroline/nafion. The electrochemical parameters were optimized for the proposed system and the voltammetric technique of square wave was employed for iron determination. An accumulation time of 5 minutes, such as a 100 mV of pulse magnitude (E(sw)) and frequency (f) of 25 Hz were used as optimized experimental conditions. The modified carbon paste electrode presented linear dependence of amperometric signal with iron concentration in a work range from 6.0x10(-6) until 2.0x10(-5) mol L(-1) of iron, exhibiting a linear correlation coefficient of 0.9884, a detection limit of 2.4 x10(-6) mol L(-1) (n = 3) and amperometric sensibility of 4.5x10(5) mu A/mol L(-1). Analytical curve method was used for iron determination at a commercial fuel sample. Flame atomic absorption spectroscopy was employed as comparative technique.
Resumo:
Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.
Resumo:
Background: Significant morbidity and mortality are related to conventional aortic replacement surgery. Endovascular debranching techniques, fenestrated or branched endografts are time consuming and costly.Objective: We alternatively propose to use endovascular approach with parallel grafts for debranching of aortic arch.Methods: Under general anesthesia, 12 F sheaths were inserted in the femoral, axillary and common carotid arteries for vascular accesses. ViaBahn grafts 10 - 15 cm in length were placed into the aortic arch from right common carotid, left common carotid and left axillary arteries, until the tip of each graft reached into the ascending aorta. Through one femoral artery, the aortic stent-graft was positioned and delivered. Soon after, the parallel grafts were sequentially delivered. Self-spanding Wallstents(R) were used for parallel grafts reinforcement. Ballooning was routinely used for parallel grafts and rarely for aortic graft.Results: This technique was used in 2 cases. The first one was a lady with 72 years old, with an aortic retrograde dissection from left subclavian artery and involving remaining arch branches. Through right common carotid artery a stent-graft was placed in the ascending aorta and through the left common carotid artery a ViaBahn was inserted parallel to the former. A thoracic endograft then covered all the aortic arch dissection extending into the ascending aorta close to the sinu-tubular junction. The second case was a 82 year old male patient with a 7 cm aortic arch aneurysm. Through both common carotid arteries ViaBahn grafts were introduced and positioned into the ascending aorta. Soon after, the deployment of the thoracic stent graft covered all parallel grafts of the aortic arch, excluding the aneurysm. Both cases did not have neurologic or cardiac complications and were discharged 10 days after the procedure.Conclusions: This technique may be a good minimal invasive off-the-shelf technical option for aortic arch "debranching". More data and further improvements are required before this promising technique can be widely advocated. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Limitations of endovascular thoracic aneurym treatment include small, tortuous, or severely calcified iliac Back, arteries. We present our experience with a total laparoscopic access to deploy thoracic endografts.Methods. A total laparoscopic left retrocolic approach was used in all cases. A Dacron conduit was laparoscopically sutured to either the iliac artery or to the aorta directly. The endograft was inserted through this conduit. After graft deployment, the Dacron prosthesis was tunneled to the groin and anastomosed with the femoral artery.Results. The laparoscopic procedure could successfully be performed in 11 patients. In six cases, the aorta was used as all access and in five patients, the iliac arteries were preferred. In one of these cases, the right iliac artery, was used for deployment of the endograft. After successful aorto- or ileo-femoral bypass grafting, all patients had an improvement of their ankle brachial index postoperatively. The mean operative time was almost four hours, including laparoscopy, laparoscopic anastomosis, endograft deployment, and femoral artery anastomosis or profundaplasty.Conclusion: Totally laparoscopic assisted graft implantation in aorta or iliac arteries provides a safe and effective access for the endovascular delivery system. However, further evaluation and long follow-up are necessary to ensure the potential advantages of this technique. It is a less invasive option to overcome access-related problems with thoracic endograft deployment, giving the patient the advantage of a totally minimal invasive procedure. (J Vasc Surg 2010;51:504-8.)
Resumo:
Objetivo: avaliar os efeitos da histerectomia total abdominal (HTA) sobre o fluxo sangüíneo ovariano, em mulheres no menacme, por meio da dopplervelocimetria e ultra-sonografia transvaginal. Métodos: estudo prospectivo no qual foram incluídas 61 mulheres, com idade igual ou inferior a 40 anos. As pacientes foram divididas em dois grupos: G1, com 31 pacientes submetidas à HTA, e G2, com 30 mulheres normais não submetidas à cirurgia. Somente foram incluídas pacientes eumenorréicas, ovulatórias, não-obesas ou fumantes, sem cirurgias ou doenças ovarianas prévias. Avaliou-se o fluxo sangüíneo das artérias ovarianas, inicialmente e aos 6 e 12 meses, pelo índice de pulsatilidade (IP) na dopplervelocimetria, e o volume ovariano pela ultra-sonografia transvaginal (US). Para análise estatística empregou-se teste t pareado, análise de perfil, teste de Friedman e teste de Mann-Whitney. Resultados: na comparação estatística inicial os grupos foram homogêneos quanto às características epidemiológicas e quanto aos demais parâmetros avaliados neste estudo. Nas pacientes submetidas à histerectomia, observaram-se aos 6 e 12 meses aumento do volume ovariano ao US e diminuição do IP avaliado pela dopplervelocimetria (p<0,05), quando confrontadas ao controle. Aos 12 meses, em 8 das 31 pacientes pós-HTA (25,5%) verificou-se ocorrência de cistos ovarianos de aspecto benigno. No grupo controle não houve alteração de nenhum desses parâmetros. Conclusão: a redução do IP na dopplervelocimetria das artérias ovarianas sugere aumento do fluxo sangüíneo ovariano pós-histerectomia total abdominal em mulheres no menacme.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A 59-year-old white man developed a ventral ulcer with irregular limits in the middle portion of the penis. The result of the pathologic analysis was compatible with invasive squamous cell urethral carcinoma. A total penectomy was performed. In these cases, the usually recommended urinary diversion is perineal urethrostomy. However, due to the specifications of the case, perineal urethrostomy could not be performed. The literature did not offer any other alternative for patients with this same condition. Therefore, a urethral reconstruction using a groin skin flap had to be performed. Copyright (C) 2004 S. Karger AG, Basel.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)