The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate the effects of folic acid supplementation on isolated oral cleft recurrence and fetal growth. Patients and Methods: The study included 2,508 women who were at-risk for oral cleft recurrence and randomized into two folic acid supplementation groups: 0.4 and 4 mg per day before pregnancy and throughout the first trimester. The infant outcome data were based on 234 live births. In addition to oral cleft recurrence, several secondary outcomes were compared between the two folic acid groups. Cleft recurrence rates were also compared to historic recurrence rates. Results: The oral cleft recurrence rates were 2.9% and 2.5% in the 0.4 and 4 mg groups, respectively. The recurrence rates in the two folic acid groups both separately and combined were significantly different from the 6.3% historic recurrence rate post the folic acid fortification program for this population (p = 0.0009 when combining the two folic acid groups). The rate of cleft lip with palate recurrence was 2.9% in the 0.4 mg group and 0.8% in the 4 mg group. There were no elevated fetal growth complications in the 4 mg group compared to the 0.4 mg group. Conclusions: The study is the first double-blinded randomized clinical trial (RCT) to study the effect of high dosage folic acid supplementation on isolated oral cleft recurrence. The recurrence rates were similar between the two folic acid groups. However, the results are suggestive of a decrease in oral cleft recurrence compared to the historic recurrence rate. A RCT is still needed to identify the effect of folic acid on oral cleft recurrence given these suggestive results and the supportive results from previous interventional and observational studies, and the study offers suggestions for such future studies. The results also suggest that high dosage folic acid does not compromise fetal growth. © 2013 by the authors; licensee MDPI, Basel, Switzerland.