94 resultados para Interior point methods


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The optimal reactive dispatch problem is a nonlinear programming problem containing continuous and discrete control variables. Owing to the difficulty caused by discrete variables, this problem is usually solved assuming all variables as continuous variables, therefore the original discrete variables are rounded off to the closest discrete value. This approach may provide solutions far from optimal or even unfeasible solutions. This paper presents an efficient handling of discrete variables by penalty function so that the problem becomes continuous and differentiable. Simulations with the IEEE test systems were performed showing the efficiency of the proposed approach. © 1969-2012 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a hybrid heuristic methodology that employs fuzzy logic for solving the AC transmission network expansion planning (AC-TEP) problem is presented. An enhanced constructive heuristic algorithm aimed at obtaining a significant quality solution for such complicated problems considering contingency is proposed. In order to indicate the severity of the contingency, 2 performance indices, namely the line flow performance index and voltage performance index, are calculated. An interior point method is applied as a nonlinear programming solver to handle such nonconvex optimization problems, while the objective function includes the costs of the new transmission lines as well as the real power losses. The performance of the proposed method is examined by applying it to the well-known Garver system for different cases. The simulation studies and result analysis demonstrate that the proposed method provides a promising way to find an optimal plan. Obtaining the best quality solution shows the capability and the viability of the proposed algorithm in AC-TEP. © Tübi̇tak..

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determinate the corneal diagnoses of patients underwent Penetrating Keratoplasty (PK) in the university hospital of Sao Jose do Rio Preto, São Paulo, Brazil, and their relation to age group, gender and socioeconomic factors. Methods: Retrospective analysis of 1085 registration forms of patients underwent Penetrating Keratoplasty in the university hospital of Sao Jose do Rio Preto, São Paulo, Brazil, from 2000 to 2009. The surgical indications were then correlated to age group, gender and socioeconomic factors, by chi-square test. Results: Fifty-seven percent of all Penetrating Keratoplasties were performed in male patients, and the mean age was 52.3 years. Most surgeries (90.8%) occurred by means of public health care (SUS). The main diagnosis was leukoma (23%), representing 14% of the indications for PK in males and 9% in females. Leukoma was also the diagnosis in 40% of PK performed in patients older than 60 years and in 94.4% of these surgeries in public health care users. Conclusion: The main indication for Penetrating Keratoplasty was leukoma, predominating in males, ages above 60 years and in public health care users.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Através de métodos bacteriológicos convencionais, avaliou-se a contaminação por Clostridium perfringens na ração e água utilizadas na alimentação e dessedentação de frangos de corte em diferentes regiões avícolas do interior paulista. C. perfringens esteve presente em 42 e 30% das amostras de ração e águas analisadas, respectivamente. As médias das contagens foram 6,7 x 10-2UFC mL para as amostras de água e 3,69 x 10-2UFC g para as de rações. As altas freqüências e contagens de C. perfringens verificadas nas rações e nas águas podem estar associadas à falta de higiene geral na manipulação e armazenamento dos mesmos. Sugere-se o monitoramento periódico da presença de C. perfringens nestas fontes, com a finalidade de evitar tal patógeno, em vista que o mesmo pode causar um surto de enterite necrótica levando, assim a grandes prejuízos na produção avícola.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In general, a land-based mobile mapping system is featured by a vehicle with a pair of video cameras mounted on the top and positioning and navigation sensors loaded in the vehicle. Considering the pair of video cameras mounted on the roof of the vehicle as a stereo camera pointing forward with both optical axes parallel to each other and orthogonal to the stereo base, whose length is 0.94 m, this paper aims at analyzing the interior and exterior camera orientation and the object point coordinates estimated by phototriangulation when the length constraint related to the stereo base is considered or not. The results show that the stereo base constraint has effect ouver the convergence estimation, but does it neither improves the object point coordinate estimation at significance level of 5% and nor it influences the interior orientation parameters. Finally, it has been noticed that the optical axes are not truly parallel to each other and orthogonal to the stereo base. Additionally, it has been observed that there is a convergence of approximately 0.5 degrees in the optical axes and they are not in the same plane (approximately 0.8 degrees deviation).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)