148 resultados para Validation of analytical methodology
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Cyclic oligomers were identified in PET bottles used for mineral water and fruit juice using MS and H-1 and C-13 NMR: a first series cyclic trimer, a first series cyclic tetramer, a first series cyclic dimmer and a second series cyclic trimer. An analytical method to determine first series cyclic trimer in these bottles was developed and validated, using HPLC. The first series cyclic trimer levels were 316-462 mg/100 g of PET bottle. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6,0-14,0 mg L-1 para espectrofotometria direta e derivada de primeira ordem em solução aquosa, respectivamente, foi de (r) of 0,9999 para ambos os casos. Os métodos foram aplicados para quantificação de losartano potássico em cápsulas obtidas de farmácias de manipulação locais e demonstraram ser eficientes, fáceis de aplicar e de baixo custo. Além disso, não necessitam de reagentes poluentes e requerem equipamentos economicamente viáveis.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.
Resumo:
A simple, rapid, selective and specific high performance liquid chromatographic (HPLC) method for quantitative analysis of the triamcinolone in polylactide-co-glycolide acid (PLGA) microparticles was developed. The chromatographic parameters were reversed-phase C18 column, 250mm x 4.6mm, with particle size 5 μm. The column oven was thermostated at 35°C ± 2°C. The mobile phase was methanol/water 45:55 (v/v) and elution was isocratic at a flow-rate of 1 mL.mL-1. The determinations were performed using a UV-Vis detector at 239 nm. The injected sample volume was 10 μL. The standard curve was linear (r2 > 0.999) in the concentration range 100-2500 ng.mL-1. The method showed adequate precision, with a relative standard deviation (RSD) was smaller than 3%. The accuracy was analyzed by adding a standard drug and good recovery values were obtained for all drug concentrations used. The method showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for quantitation of triamcinolone in PLGA microparticles.
Resumo:
Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
The validation of a microbiological assay, applying agar diffusion method for determination of the active of cefuroxime in power for injection, is described. Using a strain of Micrococcus luteus ATCC 9341 as the test organism, cefuroxime was measured in concentrations ranging from 30.0 to 120.0 μg/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation = 0.37%) and accurate (it measured the added quantities). Microbiological assay is satisfactory for quantitation of cefuroxime in powder for injection and the validity of the proposed bioassay, which is a simple and a useful alternative methodology for cefuroxime determination in routine quality control.
Resumo:
Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Resumo:
Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.