Comparative study of analytical methods by direct and first-derivative UV spectrophotometry for evaluation of losartan potassium in capsules


Autoria(s): Bonfilio, Rudy; Favoretto, Lívia Botacini; Pereira, Gislaine Ribeiro; Azevedo, Roberta de Cássia Pimentel; Araújo, Magali Benjamim de
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/03/2010

Resumo

O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6,0-14,0 mg L-1 para espectrofotometria direta e derivada de primeira ordem em solução aquosa, respectivamente, foi de (r) of 0,9999 para ambos os casos. Os métodos foram aplicados para quantificação de losartano potássico em cápsulas obtidas de farmácias de manipulação locais e demonstraram ser eficientes, fáceis de aplicar e de baixo custo. Além disso, não necessitam de reagentes poluentes e requerem equipamentos economicamente viáveis.

Losartan potassium is an antihypertensive non-peptide agent, which exerts its action by specific blockade of angiotensin II receptors. The aim of the present study was the validation and application of analytical methods for the quality control of losartan potassium 50 mg in pharmaceutical capsules, using direct and first-derivative UV spectrophotometry. Based on losartan potassium spectrophotometric characteristics, a signal at 205 nm of the zero-order spectrum and a signal at 234 nm of the first-derivative spectrum, were found adequate for quantification. The results were used to compare these instrumental techniques. The linearity between the signals and concentrations of losartan potassium in the ranges of 3.0-7.0 mg L-1 and 6.0-14.0 mg L-1 for direct and first-derivative spectrophotometry in aqueous solutions, respectively, presented a correlation coefficient (r) of 0.9999 in both cases. The methods were applied for losartan potassium in capsule dosage obtained from local pharmacies, and were shown to be efficient, easy to apply and low cost. These methods do not use polluting reagents and require relatively inexpensive equipment.

Formato

147-155

Identificador

http://dx.doi.org/10.1590/S1984-82502010000100017

Brazilian Journal of Pharmaceutical Sciences. Universidade de São Paulo, Faculdade de Ciências Farmacêuticas, v. 46, n. 1, p. 147-155, 2010.

1984-8250

http://hdl.handle.net/11449/7942

10.1590/S1984-82502010000100017

S1984-82502010000100017

S1984-82502010000100017.pdf

Idioma(s)

eng

Publicador

Universidade de São Paulo (USP), Faculdade de Ciências Farmacêuticas

Relação

Brazilian Journal of Pharmaceutical Sciences

Direitos

openAccess

Palavras-Chave #Losartano potássico #Espectrofotometria direta #Espectrofotometria derivada de primeira ordem #Losartan potassium #Direct UV spectrophotometry #First-derivative UV spectrophotometry
Tipo

info:eu-repo/semantics/article