45 resultados para Signal-to Noise Ratio (SNR)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wavelets are being extensively used in Geodetic applications. In this paper, the Multi-Resolution Analysis (MRA) using wavelets is applied to pseudorange and carrier phase GPS double differences (DDs) in order to reduce multipath effects. The wavelets were already applied to GPS carrier phase DDs, but some questions remain: How good can be the results, and are all multipath effects reduced? The answers to these questions are discussed in this paper. Thus, the wavelet transform is used to decompose the DD signals, splitting them in lower resolution components. After the decomposition process, the wavelet shrinkage is performed by thresholding to eliminate the components relative to multipath effects. Then, the DD observation can be reconstructed. This new DD signal is used to perform the baseline processing. The daily multipath repeatability was verified. With the application of the proposed approach, the results showed that the reliability of the ambiguity resolution and accuracy of the results improved when compared with the standard procedure. Furthermore, the method showed to be very efficient computationally, because, it is not noticed, at practical level, difference in the time span between the processing with and without application of the proposed method. However, only the high frequency multipath was eliminated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the use of Au nanoparticle (NP)-containing hydrogel microstructures in the development of electrochemical enzyme-based biosensors. To fabricate biosensors, AuNPs were conjugated with glucose oxidase (GOX) or horseradish peroxidase (HRP) molecules and were dispersed in the prepolymer solution of poly(ethylene glycol) diacrylate (PEG-DA). Vinylferrocene (VF) was also added into the prepolymer solution in order to lower operating potential of the biosensor and to prevent oxidation of interfering substances. The prepolymer solution was photolithographically patterned in alignment with an array of Au electrodes fabricated on glass. As a result, electrode arrays became functionalized with AuNP/GOX- or AuNP/HRP-carrying hydrogel microstructures. Performance of the biosensors was characterized by impedance spectroscopy, chronoapmerometry and cyclic voltammetry. Impedance measurements revealed that inclusion of Au nanoparticles improved conductivity of PEG hydrogel by a factor of 5. Importantly, biosensors based on AuNP-GOX complex exhibited high sensitivity to glucose (100μAmM -1cm -2) in the linear range from 0.1 to 10mM. The detection limit was estimated to be 3.7×10- 7M at a signal-to-noise ratio of 3. Biosensors with immobilized AuNP/HPR had a linear response from 0.5 to 5.0μM of hydrogen peroxide with sensitivity of 1.4mAmM -1cm -2. The method for fabricating nanoparticle-carrying hydrogel microstructures described in this paper should be widely applicable in the development of robust and sensitive electrochemical biosensors. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R 2 =0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w-1) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. © 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Box-Cox transformation is a technique mostly utilized to turn the probabilistic distribution of a time series data into approximately normal. And this helps statistical and neural models to perform more accurate forecastings. However, it introduces a bias when the reversion of the transformation is conducted with the predicted data. The statistical methods to perform a bias-free reversion require, necessarily, the assumption of Gaussianity of the transformed data distribution, which is a rare event in real-world time series. So, the aim of this study was to provide an effective method of removing the bias when the reversion of the Box-Cox transformation is executed. Thus, the developed method is based on a focused time lagged feedforward neural network, which does not require any assumption about the transformed data distribution. Therefore, to evaluate the performance of the proposed method, numerical simulations were conducted and the Mean Absolute Percentage Error, the Theil Inequality Index and the Signal-to-Noise ratio of 20-step-ahead forecasts of 40 time series were compared, and the results obtained indicate that the proposed reversion method is valid and justifies new studies. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)