69 resultados para ROTARY INSTRUMENTS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.
Resumo:
Nickel-titanium rotatory systems should remove dentin during the root canal preparation to promote the enlargement and tapered shape with continuously narrowing towards the apex. Objective: The aim of this study was to analyze the cutting ability of three NiTi rotatory systems (n = 12): ProTaper (group 1), Mtwo (group 2), and K3 (group 3). Material and methods: Thirty six maxillary molar teeth were weighted on an analytical balance before and after the rotatory preparation of the mesio-buccal root canal. Data was statistically analyzed by ANOVA and Tukey s test with a significance level of 5%. Results: The results revealed the following mass differences (g) before and after the root canal preparation: ProTaper (group 1 – 0.0159 ± 0.004), Mtwo (group 2 – 0.0125 ± 0.002), and K3 (group 3 – 0.007 ± 0.003). Conclusion: ProTaper showed the highest cutting ability among the three tested nickel-titanium rotatory systems followed by Mtwo and K3.
Resumo:
O preparo do solo é um dos processos que aceleram a decomposição da matéria orgânica, transferindo carbono para atmosfera, principalmente na forma de CO2. Neste trabalho, investigou-se o efeito do preparo com enxada rotativa sobre as emissões de CO2 do solo durante 02 semanas após o preparo do solo, incluindo-se a presença de resíduos vegetais sobre a superfície. As emissões foram avaliadas por 15 dias após preparo em 3 parcelas: 1) sem preparo e sem palha superficial (SPs); 2) preparo com enxada rotativa sem a presença de palha na superfície (ERs), e 3) preparo com enxada rotativa com a presença de palha superficial (ERc). As emissões provenientes da ERc foram superiores às demais (0,777 g CO2 m-2 h-1), sendo as menores emissões registradas na parcela SPs (0,414 g CO2 m-2 h-1). As emissões totais indicaram que a diferença de C-CO2 emitida à atmosfera corresponde a 3% do total de carbono adicional presente na palha, na parcela ERc, quando comparado à parcela ERs. O aumento da emissão da parcela SPs para ERs foi acompanhado de uma modificação na distribuição do tamanho de agregados, especialmente aqueles com diâmetro médio inferior a 2 mm. O aumento da emissão da parcela ERs para ERc esteve relacionado a uma diminuição da massa de palha na superfície, com fragmentação e incorporação da mesma no interior do solo. Quando se analisa a correlação linear entre emissão de CO2 versus temperatura e umidade do solo, somente a emissão da ERc foi significativamente correlacionada (p<0,05) à umidade do solo.
Resumo:
This study examined a new conservation tillage tool, the rotary paraplow. Emphasis was placed on evaluating the tool's conservation potential using dimensionless graph analysis. The dynamic conditions of the soil were investigated in terms of physical soil properties. Having determined the variables to be measured, dimensional analysis was used to plan the experiments. Two variations were considered for each dependent variable (linear speed, working depth, and rotation velocity), totaling eight treatments, allotting in each an experimental strip with five data collection points. This arrangement totaled 16 experimental strips, with 80 data collection points for all variables. The rotary paraplow generates a trapezoidal furrow for planting with a very wide bottom and narrower at the top. The volumetric subsoiling action generates cracks on the sides of the band. Because of their specific geometry the blades of rotary paraplow generate a soil failure according to its natural crack angle, optimizing the energy use, while preserving the natural soil properties. Results showed the conservation character of the rotary paraplow, capable of breaking up clods for planting without changing the original physical soil properties.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present study was designed to investigate the effectiveness of different ultrasonic instruments on the root surface. Fourteen patients with 35 single root teeth designated for extraction were recruited to the present study. Teeth were assigned to four experimental groups: group 1, piezoelectric ultrasonic device; group 2, magnetostrictive ultrasonic device; group 3, hand instrumentation; and group 4, untreated teeth (control). After instrumentation, the teeth were extracted and the presence of residual deposits (roughness and root surfaces characteristics) were analyzed. The results showed that residual deposits were similar in all tested groups: piezoelectric, 8.7%; magnetostrictive, 9.7%; hand instrumentation, 11.1% and control, 76.4%. There were statistically significant differences between control and all the experimental groups (p < 0.0001). With respect to roughness parameters evaluation, R(a) and R(z) of the roots treated with the different instruments showed a similar pattern (p > 0.05), but for R(t) and R(y), a significant difference was observed (p < 0.05) among hand instrumentation and ultrasonic devices. SEM analysis revealed a similar root surface pattern for the ultrasonic devices, but curettes showed many instrumental scratches, deep gouges, and a relatively large amount of dentin was removed. Within the limits of the study, although the instruments produced similar results, root surfaces instrumentated with curettes were rougher and had more root surface tissue removed than with the ultrasonic device.
Resumo:
Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Estudou-se a técnica de núcleo-fragmentação para a extração da lente em seis eqüinos adultos, utilizando-se instrumentais cirúrgicos adaptados. Nas avaliações pós-operatórias, verificou-se diminuição da pressão intra-ocular, em todos os animais, nos primeiros dias de pós-operatório e, ainda, fotofobia, blefarospasmo, edema de córnea e iridociclites, em graus diversos. Observou-se produção de fibrina que, na maioria dos casos, localizava-se na porção axial da pupila, dificultando ou impedindo a visão.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Descrever o recrutamento de pacientes, instrumentos de avaliação, métodos para o desenvolvimento de estudos colaborativos multicêntricos e os resultados preliminares do Consórcio Brasileiro de Pesquisa em Transtornos do Espectro Obsessivo-Compulsivo, que inclui sete centros universitários. MÉTODO: Este estudo transversal incluiu entrevistas semi-estruturadas (dados sociodemográficos, histórico médico e psiquiátrico, curso da doença e diagnósticos psiquiátricos comórbidos) e instrumentos que avaliam os sintomas do transtorno obsessivo-compulsivo (Escala para Sintomas Obsessivo-Compulsivos de Yale-Brown e Escala Dimensional para Sintomas Obsessivo-Compulsivos de Yale-Brown), sintomas depressivos (Inventário de Depressão de Beck), sintomas ansiosos (Inventário de Ansiedade de Beck), fenômenos sensoriais (Escala de Fenômenos Sensoriais da Universidade de São Paulo), juízo crítico (Escala de Avaliação de Crenças de Brown), tiques (Escala de Gravidade Global de Tiques de Yale) e qualidade de vida (questionário genérico de avaliação de qualidade de vida, Medical Outcome Quality of Life Scale Short-form-36 e Escala de Avaliação Social). O treinamento dos avaliadores consistiu em assistir cinco entrevistas filmadas e entrevistar cinco pacientes junto com um pesquisador mais experiente, antes de entrevistar pacientes sozinhos. A confiabilidade entre todos os líderes de grupo para os instrumentos mais importantes (Structured Clinical Interview for DSM-IV, Dimensional Yale-Brown Obsessive-Compulsive Scale, Universidade de São Paulo Sensory Phenomena Scale ) foi medida após seis entrevistas completas. RESULTADOS: A confiabilidade entre avaliadores foi de 96%. Até março de 2008, 630 pacientes com transtorno obsessivo-compulsivo tinham sido sistematicamente avaliados. A média de idade (±SE) foi de 34,7 (±0,51), 56,3% eram do sexo feminino e 84,6% caucasianos. Os sintomas obsessivo-compulsivos mais prevalentes foram os de simetria e os de contaminação. As comorbidades psiquiátricas mais comuns foram depressão maior, ansiedade generalizada e transtorno de ansiedade social. O transtorno de controle de impulsos mais comum foi escoriação neurótica. CONCLUSÃO: Este consórcio de pesquisa, pioneiro no Brasil, permitiu delinear o perfil sociodemográfico, clínico e terapêutico do paciente com transtorno obsessivo-compulsivo em uma grande amostra clínica de pacientes. O Consórcio Brasileiro de Pesquisa em Transtornos do Espectro Obsessivo-Compulsivo estabeleceu uma importante rede de colaboração de investigação clínica padronizada sobre o transtorno obsessivo-compulsivo e pode abrir o caminho para projetos semelhantes destinados a integrar outros grupos de pesquisa no Brasil e em todo o mundo.
Resumo:
Aim the aim of this study was to evaluate the efficacy of ultrasound in cleaning the surface of stainless steel and Ni-Ti endodontic instruments.Methodology Twenty nickel-titanium instruments (10 Quantec files and 10 Nitiflex) and 20 stainless steel K-files (10 Maillefer-Dentsply and 10 Moyco Union Broach) were removed from their original packages and evaluated using a scanning electron microscope. Scores were given for the presence of residues on the surface or the instruments. The instruments were then cleaned in an ultrasonic bath containing only distilled water or detergent solution for 15 min, and re-evaluated, using scanning electron microscopy.Results Before cleaning, a greater amount of metallic debris was observed on the nickel-titanium Quantec instruments (P < 0.05), when compared to those made of stainless steel. Statistical analysis showed that the use of ultrasound was effective for cleaning the instruments, regardless of the irrigating solution or the instruments type (P < 0.05).Conclusions the use of ultrasound proved to be an efficient method for the removal of metallic particles from the surface of stainless steel and Ni-Ti endodontic instruments.
Resumo:
Objective. To evaluate the healing of experimentally induced chronic periapical lesions in dogs at 30, 75, and 120 days after root canal instrumentation with rotary NiTi files or manual K-files, with or without a calcium hydroxide/1% chlorhexidine paste intracanal dressing.Study design. The second, third, and fourth mandibular premolars and the second and third maxillary premolars of 5 dogs (12 to 18 months of age, weighing 8 to 15 kg) were selected for treatment (a total of 82 root canals). After pulp removal, the root canals were left exposed to the oral cavity for 7 days to allow microbial contamination, after which the root canals were sealed with ZOE cement until periapical lesions were confirmed with radiography. Group I and II teeth were instrumented with manual K-files using the crown-down technique. In group III and IV teeth, NiTi rotary files were used. The apical delta was perforated by using #20 to #30 K-files at the length of the tooth, thus creating a standardized apical opening. The apical stop was enlarged to size 70, with 2.5% sodium hypochlorite irrigation at each file change. Teeth in groups II and IV were dressed with calcium hydroxide (Ca(OH)(2))/1% chlorhexidine (CHX) paste for 15 days before root filling. Group I and III teeth did not receive an intracanal dressing. The access openings of the teeth were permanently restored with silver amalgam condensed on a glass ionomer cement base. Pairs of standardized periapical radiographs were taken at the beginning of the treatment (0 days) and at 30, 75, and 120 days after filling.Results. There was no significant difference in the rate of radiographic healing of the periapical lesions between manual and rotary instrumentation. Radiographs taken at 120 days showed that the treatment with Ca(OH)(2)/1% CHX paste resulted in a significant reduction in mean size of the periapical lesions in comparison to single-session treatment. These findings were also true for histologic observations.Conclusion. The findings support the hypothesis that, regardless of the instrumentation technique (manual or rotary), the use of an intracanal dressing is important in the endodontic treatment of dog's teeth with experimentally induced chronic periapical lesions.