Clinical Comparison of the Effectiveness of Single-file Reciprocating Systems and Rotary Systems for Removal of Endotoxins and Cultivable Bacteria from Primarily Infected Root Canals


Autoria(s): Martinho, Frederico C.; Gomes, Ana P. M.; Fernandes, Aleteia M. M.; Ferreira, Nadia S.; Endo, Marcos S.; Freitas, Lilian E.; Camoes, Izabel C. G.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

03/12/2014

03/12/2014

01/05/2014

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Processo FAPESP: 12/19536-5

Introduction: This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria from primarily infected root canals. Methods: Forty-eight primarily infected root canals were selected and randomly divided into 4 groups: WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) (n = 12); Reciproc (VDW, Munich, Germany) (n = 12), ProTaper (Dentsply Maillefer) (n = 12), and Mtwo (VDW) (n = 12). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. Results: In the baseline samples (ie, samples collected before chemomechanical preparation), endotoxins and cultivable bacteria were recovered from 100% of the root canal samples. No differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems (ie, WaveOne [95.15%] and Reciproc [96.21%]) and with rotary systems (ie, ProTaper [97.98%] and Mtwo [96.34%]) (P < .05). Both single-file reciprocating systems (ie, WaveOne [99.45%] and Reciproc [99.93%]) and rotary systems (ProTaper [99.85%] and Mtwo [99.41%]) were effective in reducing the cultivable bacteria (all P < .05). Moreover, the culture analysis revealed no differences in bacterial load reduction (P > .05). Conclusions: Both single-file reciprocating systems (ie, WaveOne and Reciproc instruments) and rotary systems (ie, ProTaper and Mtwo instruments) showed similar effectiveness in reducing endotoxins and cultivable bacteria from primarily infected root canals, but they were not able to eliminate them from all root canals analyzed.

Formato

625-629

Identificador

http://dx.doi.org/10.1016/j.joen.2013.12.006

Journal Of Endodontics. New York: Elsevier Science Inc, v. 40, n. 5, p. 625-629, 2014.

0099-2399

http://hdl.handle.net/11449/112981

10.1016/j.joen.2013.12.006

WOS:000335873200005

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

Journal of Endodontics

Direitos

closedAccess

Palavras-Chave #Bacteria #disinfection #endodontics #endotoxin #root canal
Tipo

info:eu-repo/semantics/article