221 resultados para remoção biológica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Horticultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate possible histopathological liver of tilapia fed diets containing fish silage and level protein. Sample of 180 fed with tilapia fingerlings fed with diets containing three protein levels (20, 24 and 28% CP), and Proportions residue fermented silage of tilapia (1/4 and 1/2) of were analyzed during 75 days. The tissue fragments were fixed in Bouin and included in Histosec (R). After that, between 2 to 5 mu m slices were done in a rotation microtome. The methods used for tissue analysis were hematoxilin/eosin and PAS. The histological slices were examined under light microscope (Olympus BX-50). The disarray in the morphology of the liver of fish fed biological silage was influenced by high protein levels, and increased proportions of 1/2 of animal protein diets. It was observed that the variation of hepatocytes is directly related to the type of diet for fish. In fish fed diets containing 28% CP, the liver showed disruption of the structure cordon of hepatocytes, necrosis and shifting points of the core to the periphery. Elevated levels of biological fish silage cause deleterious changes in the liver. The level of protein required to maintain the health of the associated development fish is 24% crude protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with the synthesis, spectroscopic characterization of mono and polynuclear Pd(II) compounds obtained from the reaction between [PdCl2(MeCN)2] precursor and imidazolidine-2-thione (L1) and benzimidazoline-2-thione (L2). The interaction between [PdCl2(MeCN)2] and imidazolidine-2-thione, in the 1:2 molar ratio, using MeOH as solvent, yielded compound [Pd2Cl4(L1)4]Cl2 (1) whereas the complex [Pd2Br4(L1)4]Br2 (2) was obtained from the reaction between 1 and Br- ions. Binuclear compounds of general formulae [Pd2(L2)4]X23/2 MeOH {X= Cl-(3), Br-(4)} were synthesized using benzimidazoline-2-thione as ligand, employing the same procedure used in the synthesis of 1 and 2, respectively. The new complexes 1-4 are crystalline, air stable and soluble in methanol and dmso. The compounds were characterized by elemental analysis, IR spectroscopy, ESI/MS mass spectrometry and thermogravimetry. Coordination of the ligands L1 and L2 via sulphur atom was evidenced by the shift of the CS band (~499 cm-1, 1 and 2; ~620 cm-1, 3 and 4) to lower frequencies in comparison with those found in the free ligands (510 cm-1, L1; 660 cm-1, L2), indicating the weakening of the CS bom after coordination. ESI/EM mass spectra (positive mode) of the complexes 1-4 allowed atribute the molecular formulae [Pd2X4(L1)4]X2 {X= Cl-(1), Br-(2)} and [Pd2(L2)4]X2 {X= Cl-(3), Br-(4)} by the appearance of the peaks at m/z 794,61 [(1) + MeOH]+, m/z 836,77 [(2) - 2H - L1]+, m/z 810 [(3) - 2Cl]+, m/z 810 [(4) - 2Br]+. The TG-DTA curves showed that the complexes 1 and 2 are thermally stable up to 212 and 169º C, respectively, and further decompose to metallic palladium at 527º C (1, obt. 28,46 %; calcd. 27,88%) and 895º C (2, obt. 22,85 %; calcd. 22,62%). Compounds 3 and 4 exhibited an initial mass loss of ~5% between 25 -146º C related to the release of metanol molecules. The complexes 3...Fujimura Leite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.