232 resultados para Determination of aluminium in water


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324. 754 nm, 327. 396 nm, 222. 570 nm, 249. 215 nm and 224. 426 nm were evaluated and main figures of merit established. Absorbance measurements at 324. 754 nm, 249. 215 nm and 224. 426 nm allows the determination of Cu in the 0. 07-5. 0 mg L -1, 5. 0-100 mg L -1 and 100-800 mg L -1 concentration intervals respectively with linear correlation coefficients better than 0. 998. Limits of detection were 21 μg L -1, 310 μg L -1 and 1400 μg L -1 for 324. 754 nm, 249. 215 nm and 224. 426 nm, respectively and relative standard deviations (n = 12) were ≤ 2. 7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new palladium chelate compound is described for the determination of sulfide in aqueous samples. The reagent, bis(2-aminobenzoate)palladium(II) (PdA 2), was prepared by reaction of tetrachloropalladate (PdCl 4 -) with 2-aminobenzoic acid. The compound was characterized by infrared spectroscopy and CHN elemental analysis. The measurement was based on the selective reaction of PdA 2 with sulfide in an aqueous medium, which quantitatively produced fluorescent 2-aminobenzoate (λ ex=245nm, λ em=410nm). The analytical response was linear in the range 0.10-20.0μmol (S 2-) L -1 (r>0.99), with a limit of detection of 0.075μmolL -1 and repeatability (RSD) of 3.4%. There was no interference from CO 3 2-, NO 3 -, Cl -, SO 4 2-, Br -, NO 2 -, K +, NH 4 +, Na +, citrate or S 2O 8 2-. The fluorescence intensity decreased in the presence of H 3CCOO -, PO 4 3- and SCN -, while OH - caused a positive interference. The new fluorescent compound was successfully applied for the determination of sulfide in synthetic wastewater and natural water sample. The advantages of the proposed palladium chelate are absence of toxic by-products, simple synthesis procedure of reagent and yield reaction of about 85%, easy handling and fast acquirement of analytical signal. © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A nickel modified boron doped diamond (Ni-BDD) electrode and nickel foil electrode were used in the determination of methanol in alkaline solutions. The Ni-BDD electrode was electrodeposited from a 1 mM Ni(NO(3))(2) solution (pH 5), followed by repeat cycling in KOH. Subsequent analysis utilised the Ni(OH)(2)/NiOOH redox couple to electrocatalyse the oxidation of methanol. Methanol was determined to limits of 0.3 mM with a sensitivity of 110 nA/mM at the Ni-BDD electrode. The foil electrode was less sensitive achieving a limit of 1.6 mM and sensitivity of 27 nA/mM. SEM analysis of the electrodes found the Ni-BDD to be modified by a quasi-random microparticle array.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clotrimazole was shown to react at room temperature in Britton Robinson buffer pH 2 with the reactive dye Procion Red HE-3B. The product exhibited a differential pulse polarographic peak at -0.38 V, which was well separated from the peaks of the reactive dye at -0.08, -0.80 and -0.95 V, and this allowed the indirect determination of clotrimazole in the presence of excess of the reactive dye. The method has been applied satisfactorily to the determination of clotrimazole in pharmaceutical formulations, calibration graphs are rectilinear up to at least 40 mug ml(-1). The detection limit was calculated to be 2.6 mug ml(-1) (3 sigma). (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cefaclor is not reducible at a mercury electrode, but it can be determined polarographically and by cathodic stripping voltammetry as its initial alkaline degradation product which is obtained in high yield by hydrolysis of cefaclor in Britton-Robinson (B-R) buffer pH 10 at 50 degrees C for 30 min (reduction peak at pH 10, -0.70 V). Differential pulse polarographic calibration graphs are linear up to at least 1 x 10(-4) mol l(-1). Recoveries of 93% of the cefaclor (n = 3) were obtained from urine spiked with 38.6 mu g ml(-1) using this polarographic method with 1 ml urine made up to 10 ml with pH 10 buffer. Using cathodic stripping voltammetry and accumulating at a hanging mercury drop electrode at -0.2 V for 30 s, linear calibration graphs were obtained from 0.35 to 40 mu g ml(-1) cefaclor in B-R buffer pH 10. A relative standard deviation of 4.2% (eta = 5) was obtained, and the limit of detection was calculated to be 2.9 ng ml(-1). Direct determination of cefaclor in human urine (1 ml of urine was made up to 10 ml with pH 10 buffer) spiked to 0.39 mu g ml(-1) was made (recovery 98.6%). (C) 1999 Elsevier B.V. B.V. All rights reserved.