288 resultados para mordanted chromium


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lanthanum chromite (LaCrO3) is one of the most adequate materials for use as interconnector in solid oxide fuel cell (SOFC) applications, due to its intrinsic properties, namely its good electrical conductivity and resistance to environment conditions in fuel cell operations. Due to difficulties in sintering, additives are usually added to help in the densification process. In this work, the influence of added cobalt and strontium, in the sintering of LaCrO3 obtained by combustion synthesis was studied. The starting materials were respectively nitrates of chromium, lanthanum, cobalt and strontium, and urea was used as fuel. The results show that by increasing the strontium and cobalt concentrations it is possible to reduce the temperature of sintering. Using both additives, the sintering processes took place in lesser times than normally used for this material, as well as greater values of density were attained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interface formed between the metal and the porcelain of laser-welded Ni-Cr-Mo alloy was studied on a metallurgical basis. The characterization was carried out by using optical microscope, electron scan microscopy and X-ray dispersive spectroscopy techniques and mechanical three-point flexion tests, in the laser-welded region, with and without porcelain. The union of the porcelain with the alloy is possible only after the oxidation of the metallic surface and the subsequent application of a bonding agent known as opaque. The porcelain applied to the base metal and weld bead showed different behaviours - after the flexion test, the base metal showed cracks, while that in the weld bead broke away completely. It was noted that the region subjected to laser welding had lower adherence to the porcelain than the base metal region, due to microstructural refinement of the weld bead. These results can be shown by the X-ray dispersive spectroscopy carried out on the regions studied. The flexion tests demonstrated that the Ni-Cr-Mo alloy subject to laser welding had significant alterations in its mechanical properties after application of the porcelain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Thermal Corridor of Uruguay River is located in the triple border of Argentine, Brazil and Uruguay, and shows an intense economic thermal tourism activity, mainly based on groundwaters from Guarani Aquifer System (GAS). Recent studies have pointed out the occurrence of high concentrations of arsenic (>10 μg/L) in GAS groundwater in this area. The complex geological and hydrogeological framework in the area is associated to the Paraná Basin geological evolution south of the Assuncion-Rio Grande Arch; it encompass paleozoic marine sequences and continental sequences permian/eotriassic to mesozoic in age, which are covered by basaltic lavas of Serra Geral Formation. Iron oxide coatings have been described in sandstones of Buena Vista and Sanga do Cabral formations, which underlie GAS units. Arsenic occurrence is associated to sodium bicarbonate groundwater with pH values over 8.0. Arsenic is released to groundwater by desorption from iron oxides/hydroxides, as result of the higher pH of these waters, indicating that arsenic is released from the units that underlie GAS units. Increase in chromium and uranium concentrations are also related to high pH groundwaters, thus indicating special care on using groundwater from this region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Times of in situ incubation (144 and 288h) for determination of internal markers IADF and INDF and the effects of differents procedures (wash or not the nylon bag every 72h incubation) was evaluated in samples of diet, duodenal digesta and cattle feces. The duodenal flow dry matter and fecal production utilizing the internal markers to compare with the external marker chromium oxide there was estimated. The animals were fed with sorgum silage, concentrate or urea. In this experiment, a latin square design was used, in a factorial scheme (two times of incubation × two processing nylon bag). No was observed effect of the incubation time or processing in the internal markers INDF and IADF concentration and the in situ incubation after 144h is adequate to reproduce the indigestible markers fraction in samples. For fecal production estimation, the external marker chromium oxide presented similar result (1.26 kg day-1) as the total fecal collection (1.49 kg day-1). Both the internal markers overestimate the duodenal flow dry matter when compared with the external marker chromium oxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to determine the activities of trypsin inhibitors, hemagglutinant and tannin levels in soybean meal and in raw and processed soy, as well evaluate the protein apparent digestibility coefficient for pacu juveniles. The apparent coefficients of raw, extruded, toasted and milled soy were determined using chromium oxide (0.5%) as marker. A reference diet was created with 26% crude protein and 4,352 kcal kg-1, with each feed containing 30% of the test diet. Feces were collected by abdominal pressure. All analyzed products presented anti-nutritional factors, but the lowest trypsin inhibitor activity was observed in soybean meal. Soy that received thermal treatment presented better digestibility coefficients and lower hemagglutinating activity values than raw soy. No effects of trypsin and tannin inhibitor were observed on the protein digestibility coefficient, but a negative relationship was observed between hemagglutinin levels and protein digestibility coefficient. The use of soybean meal and extruded or toasted soy is recommended for pacu feeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. Materials and methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n=12). The crowns presented no misfit in Group A (control group) and unilateral misfits of 50μm, 100μm and 200μm in the groups B, C and D, respectively. The crowns were attached to external hexagon implants with a titanium retention screw with torque of 30N/cm. Oblique loading of 130N at 2Hz was applied on each replica, totalizing 5×104 and 1×106cycles. Detorque values were measured initially and after each cycling period. Data were evaluated by analysis of variance and Tukey's HSD test (p<0.05). Results: All groups presented reduced initial detorque values (p< 0.05) in comparison to the insertion torque (30. ± 0.5. N/cm) and Group A (25.18. N/cm) exhibited the lowest reduction. After mechanical cycling, all groups presented detorque values from 19.5. N/cm to 22.38. N/cm and the mechanical cycling did not statistically influence the detorque values regardless the misfit level of the replicas. Conclusion: The unilateral misfit influenced the preload maintenance only before mechanical cycling. The mechanical cycling did not influence the torque reduction. © 2010 Japan Prosthodontic Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

single and double marker methods were compared in seven Nellore steers with average body weight 250 kg, and previously canullated in the rumen and duodenum. The animals were fitted with continuous-infusion pump that administered CoEDTA solutions intraruminally. In addition, a capsule containing Cr 2O 3, and other, containing external n-alkanes C 32, C 36 were inserted into the rumen of each steer. Internal markers indigestible neutral-detergent fiber and acid-detergent fiber (iNDF and iADF after 144 h in situ incubation) and internal n-alkanes C 31, C 33, C 35 were components of the diet. Steers were fed with palisade grass (Brachiaria brizantha cv. marandu) in two age of regrowth, 30 and 60 days. The duodenal flow experimental design was a factorial 2×2×12 while omasal experimental design was a factorial 2×2×4. Markers iNDF, CoEDTA and the combination Co+iNDF were efficacious to estimate duodenal dry matter flow whereas iNDF, iADF and the Co+iADF combination were all efficacious to predict omasal dry matter flow. In conclusion, the double marker method for estimation of omasal and duodenal dry matter flow was the most appropriate considering the ruminal fiber digestibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High chromium content is responsible for the formation of a protective passive surface layer on austenitic stainless steels (ASS). Due to their larger amounts of chromium, superaustenitic stainless steels (SASS) can be chosen for applications with higher corrosion resistance requirements. However, both of them present low hardness and wear resistance that has limited their use for mechanical parts fabrication. Plasma nitriding is a very effective surface treatment for producing harder and wear resistant surface layers on these steel grades, without harming their corrosion resistance if low processing temperatures are employed. In this work UNS S31600 and UNS S31254 SASS samples were plasma nitrided in temperatures from 400 °C to 500 °C for 5 h with 80% H 2-20% N2 atmosphere at 600Pa. Nitrided layers were analyzed by optical (OM) and transmission electron microscopy (TEM), x-ray diffraction (XRD), and Vickers microhardness testing. Observations made by optical microscopy showed that N-rich layers were uniform but their thicknesses increased with higher nitriding temperatures. XRD analyses showed that lower temperature layers are mainly composed by expanded austenite, a metastable nitrogen supersaturated phase with excellent corrosion and tribological properties. Samples nitrided at 400 °C produced a 5 μm thick expanded austenite layer. The nitrided layer reached 25 lm in specimens treated at 500 °C. There are indications that other phases are formed during higher temperature nitriding but XRD analysis was not able to determine that phases are iron and/or chromium nitrides, which are responsible for increasing hardness from 850 up to 1100 HV. In fact, observations made by TEM have indicated that formation of fine nitrides, virtually not identified by XRD technique, can begin at lower temperatures and their growth is affected by both thermodynamical and kinetics reasons. Copyright © 2012 by ASTM International.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Supermartensitic stainless steels (SMSSs) are a new generation of the classic 13%Cr martensitic steels, lower in carbon and with additional alloying of nickel and molybdenum offering better weldabilty and low temperature toughness. Several works have shown that plasma nitriding and nitrocarburising of stainless steels at low temperatures produces a hard surface layer which results in increased wear resistance. In this work, SMSS samples were plasma nitrided and nitrocarburised at 400, 450 and 500 °C. The plasma treated SMSS samples were characterised by means of optical microscopy, microhardness, X-ray diffraction and dry wear tests. The thickness of the layers produced increases as temperature is raised, for both plasma nitriding and nitrocarburising. X-ray diffraction demonstrates that the chromium nitride content grows with temperature for nitriding and nitrocarburising, which also showed increasing content of iron and chromium carbides with temperature. After plasma treating, it was found that the wear volume decreases for all temperatures and the wear resistance increased as the treatment temperature was raised. The main wear mechanism observed for both treated and untreated samples was grooving abrasion. © 2012 IHTSE Partnership Published by Maney on behalf of the Partnership.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a silica surface chemically modified with [3-(2,2′-dipyridylamine)propyl] groups, named [3-(2,2′- dipyridylamine)propyl]silica (Si-Pr-DPA) was prepared, characterized, and evaluated for its heavy metal adsorption characteristics from aqueous solution. To our knowledge, we are the first authors who have reported the present modification. The material was characterized using infrared spectroscopy, SEM, and NMR 29Si and 13C solid state. Batch and column experiments were conducted to investigate for heavy metal removal from dilute aqueous solution by sorption onto Si-Pr-DPA. From a number of studies the affinity of various metal ions for the Si-Pr-DPA sorbent was determined to follow the order Fe(III) > Cr(III) >> Cu(II) > Cd(II) > Pb(II) > Ni(II). Two standard reference materials were used for checking the accuracy and precision of the method. The proposed method was successfully applied to the analysis of environmental samples. This ligand material has great advantage for adsorption of transition-metal ions from aqueous medium due to its high degree of organofunctionalization associated with the large adsorption capacity, reutilization possibility, and rapidity in reaching the equilibrium. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A silica surface chemically modified with [3-(2,2'-dipyridylamine) propyl] groups was prepared, characterized, and evaluated for its metal ion preconcentration in fuel ethanol. To our knowledge, we are the first authors who have reported the present modification on silica gel surface. The material was characterized using infrared spectra, scanning electronic microscopy, and 13C and 29Si solid-state NMR spectra. Batch and column experiments were conducted to investigate for metal ion removal from fuel ethanol. The results showed that the Langmuir model describes the sorption equilibrium data of the metal ions in a satisfactory way. From the Langmuir isotherms, the following maximum adsorption capacities (in mmolg -1) were determined: 1.81 for Fe(III), 1.75 for Cr(III), 1.30 for Cu(II), 1.25 for Co(II), 1.15 for Pb(II), 0.95 for Ni(II), and 0.87 for Zn(II). Thermodynamic functions, the change of free energy (ΔG), enthalpy (ΔH), and entropy (ΔS) showed that the adsorption of metal ions onto Si-Pr-DPA was feasible, spontaneous, and endothermic. The sorption-desorption of the metal ions made possible the development of a preconcentration and quantification method of metal ions in fuel ethanol. © 2012 Elsevier Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water pollution found in major rivers in Brazil has its origin from urban sewage discharges and industrial effluent, carried out by small streams and rivers crossing cities. Therefore, studies related to hydrographic micro-basins offer the opportunity to establish environmental management strategies for restoring water resources, based on diagnosis of the water quality. Despite this understanding, few studies in urban and rural areas have been performed in a systematic manner in Brazilian micro-basins. The main goal of this research was to diagnose the water resources in micro-basins in the region of the district of Americana, São Paulo state, Brazil, through the quantification of metals in water and sediment. The methodology was based on the investigation of metals (Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn), in four micro-basins, determined by inductively coupled plasma optical emission spectrometry (ICP-OES). The most significant result showed high concentration levels of chromium (969 μg L-1), downstream of the discharge of sewage from the city of Nova Odessa. This concentration in the river was above the allowed limit of Brazilian regulation agency (50 μg L-1 for Cr). Also high levels of Cr were found in the sediment (98.9 μg g-1) collected at the same monitored site. These results are important indicators of environmental performance and anthropogenic activities to help the government establish environmental management strategies aimed at the reduction of water pollution. © 2013 WIT Press.