Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
27/05/2014
27/05/2014
01/01/2011
|
Resumo |
Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. Materials and methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n=12). The crowns presented no misfit in Group A (control group) and unilateral misfits of 50μm, 100μm and 200μm in the groups B, C and D, respectively. The crowns were attached to external hexagon implants with a titanium retention screw with torque of 30N/cm. Oblique loading of 130N at 2Hz was applied on each replica, totalizing 5×104 and 1×106cycles. Detorque values were measured initially and after each cycling period. Data were evaluated by analysis of variance and Tukey's HSD test (p<0.05). Results: All groups presented reduced initial detorque values (p< 0.05) in comparison to the insertion torque (30. ± 0.5. N/cm) and Group A (25.18. N/cm) exhibited the lowest reduction. After mechanical cycling, all groups presented detorque values from 19.5. N/cm to 22.38. N/cm and the mechanical cycling did not statistically influence the detorque values regardless the misfit level of the replicas. Conclusion: The unilateral misfit influenced the preload maintenance only before mechanical cycling. The mechanical cycling did not influence the torque reduction. © 2010 Japan Prosthodontic Society. |
Formato |
12-18 |
Identificador |
http://dx.doi.org/10.1016/j.jpor.2010.05.002 Journal of Prosthodontic Research, v. 55, n. 1, p. 12-18, 2011. 1883-1958 http://hdl.handle.net/11449/72248 10.1016/j.jpor.2010.05.002 2-s2.0-78649726255 |
Idioma(s) |
eng |
Relação |
Journal of Prosthodontic Research |
Direitos |
closedAccess |
Palavras-Chave | #Dental implant #Implant-supported prosthesis #Mechanical cycling #Misfit #Preload #chromium derivative #dental alloy #dental care #denture #mechanical stress #methodology #prosthesis #tooth crown #tooth prosthesis #torque #Chromium Alloys #Crowns #Dental Abutments #Dental Alloys #Dental Prosthesis Design #Dental Prosthesis Retention #Dental Prosthesis, Implant-Supported #Dental Stress Analysis #Prosthesis Fitting #Stress, Mechanical #Torque |
Tipo |