35 resultados para MASS DETECTION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An analytical procedure using supercritical fluid extraction (SFE) and capillary gas chromatography with electron-capture detection was developed to determine simultaneously residues of different pesticides (organochlorine, organophosphorus, organonitrogen and pyrethroid) in honey samples. Fortification experiments were conducted to test conventional extraction (liquid-liquid) and optimize the extraction procedure in SFE by varying the CO2-modifier, temperature, extraction time and pressure. Best efficiency was achieved at 400 bar using acetonitrile as modifier at 90 degreesC. For the clean-up step, Florisil cartridges were used for both methods LLE and SFE. Recoveries for majority of pesticides from fortified samples of honey at fortification level of 0.01-0.10 mg/kg ranged 75-94% from both methods. Limits of detection found were less than 0.01 mg/kg for ECD and confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in selected-ion monitoring mode. The multiresidue methods in real honey samples were applied and the results of developed methods were compared. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The applicability of supercritical fluid extraction (SFE) in pesticide multiresidue analysis (organohalogen, organonitrogen, organophosphorus, and pyrethroid) in soil samples was investigated. Fortification experiments were conducted to test the conventional extraction (solid-liquid) and to optimize the extraction procedure in SFE by varying the CO2 Modifier, temperature, extraction time, and pressure. The best efficiency was achieved at 400 bar using methanol as modifier at 60 degreesC. For the SFE method, C-18 cartridges were used for the cleanup. The analytical screening was performed by gas chromatography equipped with electron-capture detection (ECD). Recoveries for the majority of pesticides from spiked samples of soil at different residence times were 1, 20, and 40 days at the fortification level of 0.04-0.10 mg/kg ranging from 70 to 97% for both methods. The detection limits found were <0.01 mg/kg for ECD, and the confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in a selected-ion monitoring mode. Multiresidue methods were applied in real soil samples, and the results of the methods developed were compared.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The incomplete combustion of biomass is one of the most important sources of emissions of organic compounds into the atmosphere, like polycyclic aromatic hydrocarbons (PAHs) which show genotoxic activity. Since environmental samples generally contain interferents and trace amounts of PAHs of interest, concentration and clean-up procedures are usually required prior to the final chromatographic analysis. This paper discusses the performance of Sep-Pak cartridges (silica gel and RP18) on clean-up of sugar cane soot extract. The best results were obtained with a silica Sep-Pak cartridge. The recoveries ranged from 79% (benzo[b]fluoranthene) to 113% (benzo[e]pyrene). (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A gas chromatography-mass-selective (GC-MS) detection method to determine buprofezin, pyridaben, and tebufenpyrad on the pulp, peel, and whole fruit of clementines is described. The extraction/partition procedure was performed in one step and no cleanup was necessary with the GC-MS in the SIM-mode pesticide determination. Recovery ranged from 75 to 124% with coefficients of variance ranging between 1 and 13%. The limit of determination was 0.01 mg/kg for all pesticides. The field trials showed a similar degradative behavior for all active ingredients (AI), with a great residue decrease during the first week and stability in the second. Just after treatment buprofezin and tebufenpyrad showed lower residues than the maximum residue limit (MRL) fixed in Italy, while pyridaben was below the MRL after a week.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A competitive enzyme-linked immunosorbent assay (ELISA) method for carbaryl quantitation in crop extracts was validated by liquid chromatography (LC) with diode array detection (DAD). For this purpose, six crops (banana, carrot, green bean, orange, peach and potato) were chosen for recovery and reproducibility studies. The general sample preparation included extraction with methanol followed by liquid-liquid partitioning and clean-up on Celite-charcoal adsorbent column of the vegetable extracts. ELISA samples consisted of a diluted LC extract in assay phosphate buffer (pH 7.5). The potential effect of methanol in these samples was evaluated. It was observed that a maximum content of 10% methanol present in the assay buffer could be tolerated without expressive losses in the ELISA performance. Under these conditions, a IC50 similar to 1.48 mu g l(-1) was obtained. A minimum matrix effect with a 1:50 dilution of the methanolic extracts in assay buffer was noticed, except for green bean samples that inhibited completely the assay. For the vegetable extracts, the ELISA sensitivities varied from 3.9 to 5.7 mu g l(-1), and good recoveries (82-96%) with R.S.D.s ranging from 5.7 to 12.1% were found. An excellent correlation between the LC-DAD and ELISA techniques was obtained. The confirmation of the carbaryl in less concentrated samples was achieved by LC-mass spectrometry interfaced with atmospheric pressure chemical ionisation. The [M + H](+)= 202 and [M + H-57](+)=145 ions, equivalent to the protonated molecular and l-naphthol ions, respectively, were used to carbaryl identification in these samples. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Absorbance detection in capillary electrophoresis (CE), offers an excellent mass sensitivity, but poor concentration detection limits owing to very small injection volumes (normally I to 10 nL). This aspect can be a limiting factor in the applicability of CE/UV to detect species at trace levels, particularly pesticide residues. In the present work, the optical path length of an on-column detection cell was increased through a proper connection of the column (75 mu m i.d.) to a capillary detection cell of 180 mu m optical path length in order to improve detectability. It is shown that the cell with an extended optical path length results in a significant gain in terms of signal to noise ratio. The effect of the increase in the optical path length has been evaluated for six pesticides, namely, carbendazim, thiabendazole, imazalil, procymidone triadimefon, and prochloraz. The resulting optical enhancement of the detection cell provided detection limits of ca. 0.3 mu g/mL for the studied compounds, thus enabling the residue analysis by CE/UV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and fast multiresidue method has been developed to determine 48 pesticides within the major groups of pesticides (organohalogen, organophosphorous, pyrethroids and organonitrogen) in representative samples of locally produced honey, in Bauru (State of São Paulo, Brazil) during 2003-2004. The recovery results found ranged from 76% to 95% and the limits of detection were lower than 0.01 mg/kg for gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). The results indicated that most pesticides found in the samples belonged to the organohalogen and organophosphorous groups and lower levels of residues of some organonitrogen and pyretroids were also detected. Malathion residues were detected in all the samples, in a high concentration, owing to its applications to control dengue mosquitoes in the area studied. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Structural Health Monitoring (SHM) has diverse potential applications, and many groups work in the development of tools and techniques for monitoring structural performance. These systems use arrays of sensors and can be integrated with remote or local computers. There are several different approaches that can be used to obtain information about the existence, location and extension of faults by non destructive tests. In this paper an experimental technique is proposed for damage location based on an observability grammian matrix. The dynamic properties of the structure are identified through experimental data using the eigensystem realization algorithm (ERA). Experimental tests were carried out in a structure through varying the mass of some elements. Output signals were obtained using accelerometers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess biochemical, anthropometric, and dietary variables considered risk factors for coronary artery disease. METHODS: Using anthropometrics, dietary allowance, and blood biochemistry, we assessed 84 patients [54 males (mean age of 55± 8 years) and 30 females (mean age of 57±7 years)], who had severe ( > or =70% coronary artery obstruction) and nonsevere forms of coronary artery disease determined by cardiac catheterization. The severe form of the disease prevailed in 70% of the males and 64% of the females, and a high frequency of familial antecedents (92% ' 88%) and history of acute myocardial infarction (80% ' 70%) were observed. Smoking predominated among males (65%) and diabetes mellitus among females (43%). RESULTS: Males and females had body mass index and body fat above the normal values. Females with nonsevere lesions had HDL > 35 mg/dL, and this constituted a discriminating intergroup indicator. Regardless of the severity of the disease, hyperglycemia and hypertriglyceridemia were found among females, and cholesterolemia > 200 mg/dL in both sexes, but only males had LDL fraction > 160 mg/dL and homocysteine > 11.7 mmol/L. The male dietary allowance was inadequate in nutrients for homocysteine metabolism and in nutrients with an antioxidant action, such as the vitamins B6, C, and folate. Individuals of both sexes had a higher lipid and cholesterol intake and an inadequate consumption of fiber. The diet was classified as high-protein, high-fat, and low-carbohydrate. CONCLUSION: The alterations found had no association with the severity of lesions, indicating the need for more effective nutritional intervention.