118 resultados para Diffuse reflectance spectroscopy
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper describes an analytical reflectometric method that has an objective not only the industrial quality control but also to detect possible falsifications and/or adulterations of propranolol in pharmaceutical formulations. The method is based on the diffuse reflectance measurements of the colored product (III) of the spot test reaction between propranolol hydrochloride (I) and 2,6-dichloroquinone-4-chloroimide (II) using filter paper as solid support. Spot test conditions have been investigated using experimental design in order to identify and optimize the critical factors. The factors evaluated were DCQ concentration, propranolol solvent and DCQ solvent. The best reaction conditions were achieved with the addition of 30 mu L, of propranolol solution in ethanol 35% (v/v) and 30 mu L of DCQ solution at 70 mg mL(-1) in acetone, in this order. All reflectance measurements were carried out at 500 nm and the linear range was from 8.45 x 10(-4) to 8.45 x 10(-2) mol L-1 (r= 0.998). The limit of detection was 1.01 x 10(-4) mol L-1. No interference was observed from the assessed excipients and drugs. The method was applied to determine propranolol in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those given by the British Pharmacopoeia procedure. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this report an analytical method to determine furosemide by using diffuse reflectance spectroscopy is presented. This study shows that this technique can give quantitative results using spot test analysis, particularly in the case of pharmaceuticals containing furosemide. The color spot test could be obtained by reaction between furosemide with p-dimethylaminocinnamaldehyde, in acid medium. This reaction produced a stable complex on filter paper after heating to 80degreesC for 5 min. All reflectance measurements were carried out at 585 nm and the linear range was from 7.56 x 10(-3) to 6.05 x 10(-2) mol l(-1), with a correlation coefficient of 0.999. The limit of detection was estimated to be 2.49 x 10(-3) mol l(-1) (R.S.D. = 1.7%) and the effect of common excipients on the reflectance measurements was evaluated. The method was applied to determine furosemide in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those of the official method, showing for the first time ever that quantitative spot test analysis by diffuse reflectance could be successfully used to determine furosemide in tablets. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This paper describes a very simple and rapid quantitative reflectance spot test procedure for the determination of methyldopa in pharmaceutical formulations. This method is based on the complexation reaction of methyldopa with molybdate ions yielding a yellow stable complex on filter paper. Reflectance measurements were carried out at 410 nm. Under optimal conditions, the calibration graphs obtained for methyldopa by plotting the optical density of the reflectance signal (A R) vs. the log of the concentration were linear from 6.30 × 10 -3 to 1.89 × 10 -2 mol L -1, with a correlation coefficient of 0.998. The detection limit was 2.74 × 10 -3 mol L -1 (R.S.D. = 1.02%) for methyldopa. The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine metyldopa in commercial pharmaceutical formulations. The results obtained by the proposed method compare favorably with those obtained by an official procedure at 95% confidence level. ©2006 Sociedade Brasileira de Química.
Resumo:
A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 μL of atenolol solution and 20 μL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13×10-2 to 7.88×10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 × 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.
Resumo:
This paper describes the development and application of a simple, cheap, and clean method for the quantification of furosemide in urine samples from athletes, to detect doping, using a combined spot test/diffuse reflectance spectroscopy procedure. The method is based on the complexation reaction of furosemide (5-(aminosulfonyl)-4-chloro-2-((furanylmethyl)amino)benzoic acid, dissolved in ethanol, with FeCl3 and the surfactant dodecyltrimethylammonium bromide (DTAB) in aqueous solution, yielding a colored compound on the surface of a filter paper. The reagent concentrations were optimized using a chemometric experimental design. The reflectometric measurements of the complex formed were carried out at 477nm. The linear range obtained was 1.65-9.00×10-3molL-1 of furosemide (R=0.997), and the detection and quantification limits were 4.9×10-4 and 1.62×10-3molL-1, respectively. The proposed method was successfully applied in the analysis of furosemide in spiked urine, demonstrating that it is a reliable alternative method for the detection of furosemide doping in sport. © 2012 Elsevier B.V..
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Mapping of clay, iron oxide and adsorbed phosphate in Oxisols using diffuse reflectance spectroscopy
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work we propose the study of the spectroscopy properties and the energy level location of Ce(3+) and Pr(3+) in Gd(2)O(2)S, along with the effects of Ce(4+) (Ce(2)O(2)S(2)) incorporation in Gd(2)O(2)S and Gd(2)O(2)S: Pr(3+) in order to understand the formation and position of the associated defects energy levels in relation to the band structure of Gd(2)O(2)S and Pr(3+) energy levels. Ce-, Pr(3+)-doped and Pr(3+), Ce-doped Gd(2)O(2)S were prepared by the sulfidization of a basic gadolinium carbonate with S(8) using H(2)/N(2) (3.0/97.0%) and air during the firing of the precursor. Samples were analyzed by X-ray diffraction in order to guarantee the formation of the Gd(2)O(2)S single phase. Diffuse reflectance spectroscopy and luminescent measurements (emission/excitation) were used to locate Ce(3+), Pr(3+) and defects energy levels in relation to the band structure of Gd(2)O(2)S. (C) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Resumo:
Selection of the proper shade and color matching of restorations to natural dentition continues to be one of the most frustrating problems in dentistry and currently available shade guide presents a limited selection of colors compared to those found in natural dentition. This investigation evaluation if the composites resins shade B2 are equivalent to the Vita shade guide B2. Twelve composite resins (Renamel Microfill Super Brite- Cosmedent USA, Renamel Universal Brite- Cosmedent USA, Renamel Microfill Body- Cosmedent USA, Renamel Universal Body- Cosmedent USA, Opallis EB2-FGM, Opallis DB2-FGM, Filtek Supreme XT-3M/ESPE, Filtek Z250-3M/ESPE, Filtek Z350-3M/ESPE, Z100-3M/ESPE, 4 Seasons Dentin - Ivoclar/Vivadent, Tetric Ceram - Ivoclar/Vivadent) shade B2 were used. From each composite, two specimens were made in a steel matrix with 8.0 mm diameter and 10.0 mm different predetermined thickness (0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 mm). The specimens were 40 seconds light polymerized by LED Ultrablue (DMC). The specimens were measured 10 times each to determine the shade using a reflectance spectrophotometer (Pocket Spec). According to results was verified that not any of composites resins shade B2 evaluated in this study presented values of color difference (ΔE) equivalent to the Vita shade guide B2 and the 2 mm thickness showed the closer match to the Vita shade guide B2.
Resumo:
In-office dental bleaching has been subject of several studies. Generally those studies quantify through visual analysis, the shade reduction of the teeth submitted to different bleaching protocols (light sources, bleaching agent concentrations and irradiation time). The objective of this work is the determination of the influence of four irradiation protocols on the obtainment of better aesthetic results using a colorimetric spectrophotometer that quantifies color changes in each situation imposed. Forty bovine incisors were selected in function of similar anatomic characteristics; a concentrated coffee solution was used to stain the teeth. A commercial spectrophotometer was used to measure the color changes during evolution of the experiment (stain and bleaching phases) and the obtained data was analyzed by the ANOVA test. The obtained data showed the evolution of teeth color during the staining period, as well as, the color reduction that each bleaching protocol achieved. Based on our findings it is possible to conclude that bleaching protocols with larger irradiation periods did not showed significant differences when compared with shorter irradiation protocols, in that way the use of protocols with 30 min or more of consecutive irradiation are not clinically justified and also can cause several side effects.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)