44 resultados para técnicas de retracción gingival
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The railroad, from 1870 and on, becomes an usual complaining in the press s and politician elite s speeches, especially because of Natal s geographic isolation. The implantation of two railroads in the capital territory Estrada de Ferro de Natal a Nova Cruz, afterwards part of Great Western Railway Company network, and Estrada de Ferro Central do Rio Grande do Norte had serious implications in the urban environment. While railroad s structures were already consolidated, other transportation mechanisms were being implanted in the first decades of the 20th century, such as trams lines, which, by the way, was a transport modal that also used rails as a dislocation meaning. Considering these questions, we may ask: how come railroads and tramways demands, roads and buildings had influenced the internal organization of Natal? We work with the general hypothesis that the influence of technical networks, composed by tramways and railroads, over Natal s urban space happened in a diversified way, sometimes consolidating social aspects in certain areas, sometimes improving the occupation of others. The impact over the city s territory also happens in a diversified way between the buildings/railroad s complexes and the pathways. The different scale of the train in comparison to the trams velocity, size, noise level, flow, among others is also a cause to the different consequences in urban environment. The main objective of this work is to understand the role of circulation technical networks in the construction process of urban space in Natal, as a way to contribute to the urban historiography about the subject. The time frame adopted, between 1881 and 1937, marks the time path of railroads and tramways in Rio Grande do Norte: 1881 is the year of railroad s first section inauguration from Natal to São José do Mipibu as well of the railroad complex in the Republic Square in Natal; the year of 1937 marks the beginning of tramways declination process in the city. At this time railroads and tramways had to face more intensively the competition of motor vehicles. The theory reference adopted is based on concepts and analysis of authors, such as Flávio Villaça and Roberto Lobato Corrêa references to the concepts of urban structure , localization and accessibility and Gabriel Dupuy to explain the concept of urban technical networks . These references reveal the conflict of different realities in the urban universe interests and values which is an important factor about the construction of urban space. The information sources used were from two distinctive natures: primary, journals of the time studied and official government reports, and secondary, based on other works about the subject. It was also used by this study iconographic source, especially images from the data base of the research group História da Cidade, do Território e do Urbanismo .
Resumo:
This work discusses the study of the application of structural reinforcement and rehabilitation using modern techniques for interventions in repair works of historical buildings as well as the verification of the behavior of works that have already undergone different structural intervention techniques, with the objective of obtaining data to allow a comparative analysis of the advantages/disadvantages of techniques adapted in each case, regarding the interferences related the authenticity and integrity of the buildings belong to the constructed patrimony so as to obtain a basis for the theoretical foundation for choosing the best solution to be adopted in the case study which consists in an intervention of structural rehabilitation of the old historic building in the primary school "Augusto Severo"
Resumo:
Oil production and exploration techniques have evolved in the last decades in order to increase fluid flows and optimize how the required equipment are used. The base functioning of Electric Submersible Pumping (ESP) lift method is the use of an electric downhole motor to move a centrifugal pump and transport the fluids to the surface. The Electric Submersible Pumping is an option that has been gaining ground among the methods of Artificial Lift due to the ability to handle a large flow of liquid in onshore and offshore environments. The performance of a well equipped with ESP systems is intrinsically related to the centrifugal pump operation. It is the pump that has the function to turn the motor power into Head. In this present work, a computer model to analyze the three-dimensional flow in a centrifugal pump used in Electric Submersible Pumping has been developed. Through the commercial program, ANSYS® CFX®, initially using water as fluid flow, the geometry and simulation parameters have been defined in order to obtain an approximation of what occurs inside the channels of the impeller and diffuser pump in terms of flow. Three different geometry conditions were initially tested to determine which is most suitable to solving the problem. After choosing the most appropriate geometry, three mesh conditions were analyzed and the obtained values were compared to the experimental characteristic curve of Head provided by the manufacturer. The results have approached the experimental curve, the simulation time and the model convergence were satisfactory if it is considered that the studied problem involves numerical analysis. After the tests with water, oil was used in the simulations. The results were compared to a methodology used in the petroleum industry to correct viscosity. In general, for models with water and oil, the results with single-phase fluids were coherent with the experimental curves and, through three-dimensional computer models, they are a preliminary evaluation for the analysis of the two-phase flow inside the channels of centrifugal pump used in ESP systems
Resumo:
The resistance of aluminum and their alloys, to the corrosion phenomenon, in aqueous solutions, is a result of the oxide layer formed. However, the corrosion process in the aluminum alloy is associated with the presence a second phase of particles or the presence of chloride ions which promote the disruption of the oxide layer located producing the corrosion process. On the other hand, the term water produced is used to describe the water after the separation of the oil and gas in API separators. The volumes of produced water arrive around 5 more times to the volume of oil produced. The greatest feature of the water is the presence of numerous pollutants. Due to the increased volume of waste around the world in the current decade, the outcome and the effect of the discharge of produced water on the environment has recently become an important issue of environmental concern where numerous treatments are aimed at reducing these contaminants before disposal. Then, this study aims to investigate the electrochemical corrosion behavior of aluminum alloy 6060 in presence of water produced and the influence of organic components as well as chloride ions, by using the electrochemical techniques of linear polarization. The modification of the passive layer and the likely breakpoints were observed by atomic force microscopy (AFM). In the pit formation potential around -0.4 to -0.8 V/EAg/AgCl was observed that the diffusion of chloride ions occurs via the layer formed with the probable formation of pits. Whereas, at temperatures above 65 °C, it was observed that the range of potential for thepit formation was -0.4 to -0.5 V/EAg/AgCl. In all reactions, the concentration of Al(OH)3 in the form of a gel was observed
Resumo:
The brazilian-plum (Spondias tuberosa, His) is a tropical fruit tree that has been consolidated in the market for agribusiness processing, due to its characteristic flavor of fruit. Accordingly, studies to optimize the propagation of plants are necessary for production of seedlings with agronomic and quality assurance measures. This study aimed at determining the efficient techniques for uniform seed germination, as brazilian-plum seed present mechanical dormancy, and establish optimal culture media for multiplication of shoots from the in vitro micropropagation. Firstly, in a greenhouse at the Universidade Federal do Rio Grande do Norte, was evaluated the influence of different methods of breaking dormancy in the emergence of seedlings of brazilian-plum and speed of germination (IVG) of seeds. After 60 days of cultivation, it was found that splay in the distal portion of the seed was the best treatment, with rates of 85.33% in germinability and 3.415 of IVG, compared with the treatment of seed-soaking in water for 12h + humus and the control group. Subsequently, new sources of seedling explants were obtained in studies of tissue culture. Laboratory of Plant Biotechnology that the university, was used stem apex, nodal segments and internodes in search of decontamination with various concentrations of calcium hypochlorite [Ca(OCl)2] and micropropagation, inoculating them in half WPM (1980) with various concentrations of 6-benzylaminopurine (BAP). We used 10 sample units with three replications for different concentrations of [Ca(OCl)2], BAP and explants type. After thirty days, which was observed for the control of contamination, during the establishment in vitro, concentrations of [Ca(OCl)2] between 0.5% and 2.0% were effective in combating exogenous contamination of the apex. In nodal segments and internodes, concentrations of [Ca(OCl)2] between 1.0% and 2.0% and 1.5% and 2.0% were respectively, sufficient to reduce the percentage of losses in these infestations explants. For micropropagation, the culture medium supplemented with 0.1 mg.L-1 BAP promotes better development of multiple shoots per explants from nodal segment. However, success does not get to shoot training in internodal segment
Resumo:
This thesis aimed to assess the increase in solubility of simvastatin (SINV) with solid dispersions using techniques such as kneading (MA), co-solvent evaporation (ES), melting carrier (FC) and spray dryer (SD). Soluplus (SOL), PEG 6000 (PEG), PVP K-30 (PVP) e sodium lauryl sulphate (LSS) were used as carriers. The solid dispersions containing PEG [PEG-2(SD)], Soluplus [SOL-2(MA)] and sodium lauryl sulphate [LSS-2(ES)] were presented with a greater increase in solubility (5.02, 5.60 and 5.43 times respectively); analyses by ANOVA between the three groups did not present significant difference (p<0.05). In the phase solubility study, the calculation of the Gibbs free energy (ΔG) revealed that the spontaneity of solubilisation of SINV occurred in the order SOL>PEG >PVP 75%>LSS, always 80%. The phase diagrams of PEG and LSS presented solubilization stoichiometry of type 1:1 (type AL). The diagrams with PVP and SOL tend to 1:2 stoichiometry (type AL + AP). The stability coefficients (Ks) of the phase diagrams revealed that the most stable reactions occurred with LSS and PVP. The solid dispersions were characterized by Fourier transform infrared (FTIR), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), particle size distribution (PSD), near-infrared spectroscopy imaging (NIR-CI) and X-ray diffraction of the powder using the Topas software (PDRX-TOPAS). The solid dispersion PEG-2(SD) presented the greatest homogeneity and the lowest degree of crystallinity (18.2%). The accelerated stability study revealed that the solid dispersions are less stable than SINV, with PEG-2(SD) being the least stable, confirmed by FTIR and DSC. The analyses by PDRX-TOPAS revealed the amorphous character of the dispersions and the mechanism of increasing solubility
Resumo:
Nowadays, telecommunications is one of the most dynamic and strategic areas in the world. Organizations are always seeking to find new management practices within an ever increasing competitive environment where resources are getting scarce. In this scenario, data obtained from business and corporate processes have even greater importance, although this data is not yet adequately explored. Knowledge Discovery in Databases (KDD) appears then, as an option to allow the study of complex problems in different areas of management. This work proposes both a systematization of KDD activities using concepts from different methodologies, such as CRISP-DM, SEMMA and FAYYAD approaches and a study concerning the viability of multivariate regression analysis models to explain corporative telecommunications sales using performance indicators. Thus, statistical methods were outlined to analyze the effects of such indicators on the behavior of business productivity. According to business and standard statistical analysis, equations were defined and fit to their respective determination coefficients. Tests of hypotheses were also conducted on parameters with the purpose of validating the regression models. The results show that there is a relationship between these development indicators and the amount of sales
Resumo:
The objective of this work is to draw attention to the importance of use of techniques of loss prevention in small retail organization, analyzing and creating a classification model related to the use of these in companies. This work identifies the fragilities and virtues of companies and classifies them relating the use of techniques of loss prevention. The used methodology is based in a revision of the available literature on measurements and techniques of loss prevention, analyzing the processes that techniques needed to be adopted to reduce losses, approaching the "pillars" of loss prevention, the cycle life of products in retail and cycles of continues improvement in business. Based on the objectives of this work and on the light of researched techniques, was defined the case study, developed from a questionnaire application and the researcher's observation on a net of 16 small supermarkets. From those studies a model of classification of companies was created. The practical implications of this work are useful to point mistakes in retail administration that can become losses, reducing the profitability of companies or even making them impracticable. The academic contribution of this study is a proposal of an unpublished model of classification for small supermarkets based on the use of techniques of loss prevention. As a result of the research, 14 companies were classified as Companies with Minimum Use of Loss Prevention Techniques - CMULPT, and 02 companies were classified as Companies with Deficient Use of Loss Prevention Techniques - CDULPT. The result of the research concludes that on average the group was classified as being Companies with Minimum Use of Techniques of Prevention of Losses EUMTPP, and that the companies should adopt a program of loss prevention focusing in the identification and quantification of losses and in a implantation of a culture of loss prevention
Resumo:
The objective of this work was to investigate the factors that inhibit the use of Environmental Techniques in the Gas Station of the city of Natal/RN. For this, a survey with the aid of a questionnaire was used like research instrument. It s used a sample for convenience, not probabilistic. For collection of the data, it was used directly application of the questionnaire to the Managers or Assistant managers of the gas station, in accordance with its availability or presence. The data was collected in all the regions of Natal (North, South, East and West). The population in accordance with the data of the ANP of September 2005 is of 111 ranks and the collected sample was of 86. To carry through the analysis of the data of this research had been used softwares Excel and Statistic version 5.0, for Windows. The analysis of data is divided in two parts; descriptive analysis and analysis of groupings (clusters). The results showed that bigger part of the interviewed ones has between 30 and 39 years of age; they have second grade completed; they had declared to have little between and reasonable knowledge how much to the use of Clean Technology (CT) in gas station; and a small part of the interviewed ones had informed to have much knowledge how much the resolutions of the CONAMA established for the Gas Station. Of the searched ranks, the majority is national(76.7%); the most accurate practice environmental used in the gas station are: it collects selective of oil used or contaminated and ecological tanks - coated with strengthened fibre glass; great part of the interviewed ones (33.8%) informed that never the TL makes planning of referring future action; about of the half of the interviewed ones (84.9%) they had more declared that its employees have of none to a reasonable level of training for deal with problems that compromise the environment; the majority of the ranks (72.1%) functions has for more then six years. It is observed that almost all the interviewed ones (96.5%) evaluate as being important or very important the implantation of CT in Gas Station and the great majority (82.1%) evaluates the difficulty in if implanting these technologies in Gas Station as being easy or very easy. In the analysis of cluster, it was verified existence of two groupings (as much in the variable of the barriers and benefits), being that inside of each clusters exists homogeneity and between clusters exists heterogeneity. In reality, everything is important or very important in the opinion of the interviewed ones. There only exists a small significant difference that separates them in clusters
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
This study presents a description of the development model of a representation of simplified grid applied in hybrid load flow for calculation of the voltage variations in a steady-state caused by the wind farm on power system. Also, it proposes an optimal load-flow able to control power factor on connection bar and to minimize the loss. The analysis process on system, led by the wind producer, it has as base given technician supplied by the grid. So, the propose model to the simplification of the grid that allows the necessity of some knowledge only about the data referring the internal network, that is, the part of the network that interests in the analysis. In this way, it is intended to supply forms for the auxiliary in the systematization of the relations between the sector agents. The model for simplified network proposed identifies the internal network, external network and the buses of boulders from a study of vulnerability of the network, attributing them floating liquid powers attributing slack models. It was opted to apply the presented model in Newton-Raphson and a hybrid load flow, composed by The Gauss-Seidel method Zbarra and Summation Power. Finally, presents the results obtained to a developed computational environment of SCILAB and FORTRAN, with their respective analysis and conclusion, comparing them with the ANAREDE
Resumo:
Artificial Intelligence techniques are applied to improve performance of a simulated oil distillation system. The chosen system was a debutanizer column. At this process, the feed, which comes to the column, is segmented by heating. The lightest components become steams, by forming the LPG (Liquefied Petroleum Gas). The others components, C5+, continue liquid. In the composition of the LPG, ideally, we have only propane and butanes, but, in practice, there are contaminants, for example, pentanes. The objective of this work is to control pentane amount in LPG, by means of intelligent set points (SP s) determination for PID controllers that are present in original instrumentation (regulatory control) of the column. A fuzzy system will be responsible for adjusting the SP's, driven by the comparison between the molar fraction of the pentane present in the output of the plant (LPG) and the desired amount. However, the molar fraction of pentane is difficult to measure on-line, due to constraints such as: long intervals of measurement, high reliability and low cost. Therefore, an inference system was used, based on a multilayer neural network, to infer the pentane molar fraction through secondary variables of the column. Finally, the results shown that the proposed control system were able to control the value of pentane molar fraction under different operational situations
Resumo:
Neste trabalho, são utilizadas a Técnica da Ressonância Transversa (TRT) e a Técnica da Ressonância Transversa Modificada (MTRT), para a determinação das freqüências dos modos ressonantes de antenas de microfita com patch quadrado, retangular e circular e com substratos isotrópicos e anisotrópicos. Para isso, é proposto um modelo da cavidade equivalente, onde a antena tipo patch retangular é representada como sendo a superposição de duas linhas infinitas em microfita, uma de largura W, representando a dimensão que expressa a largura do patch, e a outra com largura L, representando a dimensão que expressa o comprimento do patch. A avaliação da eficiência e aplicabilidade dos métodos citados é realizada comparando-se com resultados experimentais e obtidos através de outras técnicas. Três situações serão verificadas: estruturas com substrato infinito, estrutura com substrato tipo pedestal e estruturas com substrato truncado além dos limites da fita metálica. Os resultados obtidos demonstram que as técnicas de análise de onda completa utilizadas neste trabalho, por um formalismo matemático mais rigoroso, são eficientes e precisas tanto na aplicação em estruturas com substrato isotrópico como nas que possuem substrato anisotrópico. Inicialmente são consideradas apenas as estruturas com substratos isotrópicos, com diferentes constantes dielétricas, e é avaliada a influência da largura do substrato sobre as freqüências dos modos ressonantes das antenas. Posteriormente, a análise do truncamento do dielétrico é realizada para estruturas com substrato anisotrópico. Em todos os casos, os resultados experimentais, obtidos a partir da construção de protótipos, são confrontados com os obtidos a partir de simulação, utilizando as técnicas TRT e MTRT. No final, as técnicas descritas são utilizadas para antenas tipo patch circular, sendo utilizada uma técnica de equivalência para transformar a antena circular em outra quadrada ou retangular equivalente, dependendo do modo que se queira encontrar. Os resultados obtidos são então analisados, observando-se uma boa concordância e indicando a viabilidade do método. Após isso, são apresentadas as conclusões e sugeridos alguns temas para a continuidade deste trabalho
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior