43 resultados para calibração
Resumo:
The quantitative chemical characterization of the inorganic fraction of scale products is very relevant in studying, monitoring and controlling corrosive processes of oil pipelines. The X-ray fluorescence spectrometry (XRF) is a very versatile analytical technique, which can be used in quantitative analysis in solid samples at low concentrations of the chemical element, in the order of few ppm. A methodology that involves sample preparation diluted in the proportion of 1:7 (one portion of the sample for seven of wax), pressed as pellets was used in the XRF calibration for chemical analysis of scale products from oil pipelines. The calibration involved the preparation of reference samples from mixtures of P.A. reagents, aiming to optimize the time consumed in the steps of sample preparation and analysis of Al, Ba, Ca, Fe, K, Mg, Mn, Na, P, S, Si, Sr and Ti, using the same pressed pellet for trace and major elements analysis
Resumo:
PAHs (Polycyclic Aromatic Hydrocarbons) are a group of organic substances which receive considerable attention because of the carcinogenic and mutagenic properties of some of them. It is therefore important to determine the PAHs in different environmental matrices. Several studies have shown the use of gas chromatography coupled to mass spectrometry as a technique for quantification of PAHs by presenting excellent detection limits. This study aimed to develop an analytical methodology for the determination of 16 PAHs listed by the USEPA, test two methods for extraction of PAHs in water from a 23 factorial design, quantify them through the analytical technique coupled to gas chromatography mass spectrometry (GC/MS) using the method developed, and finally apply the results in chemometrics. The sample was synthesized and subjected to tests of the 23 factorial design, which has the factors: the type of extraction technique (ultrasound and digester), the ratio solvent / sample (1:1 and 1:3) and the type of solvent (dichloromethane / hexane and acetone / dichloromethane). The responses of eight combinations of the factorial design were obtained from the quantification by external calibration in GC/MS. The quantification method was developed from an optimized adaptation of the USEPA Method 8270. We used the full scan mode as a way of acquiring the mass spectra of 16 PAHs. The time in which the samples were subjected to ultrasound was fixed at 10 min and held an investigation to establish the conditions of power and time in the digester. We had the best response in the investigation of the digester power of 100 watts and the time of six minutes. The factorial design of liquid-liquid extraction showed that the most representative factors were: the use of the digester as extraction technique, the ratio solvent / sample 1:1 and the use of a 1:1 mixture of dichloromethane / hexane as a solvent more suitable. These results showed that the 1:1 mixture of dichloromethane / hexane is an excellent mixture to recover the extraction of PAHs an aqueous sample using the microwave digester. The optimization of the method of separation, identification and quantification of PAHs in the GC/MS was valid for 16 PAHs present in each chromatogram of the samples
Resumo:
In this work calibration models were constructed to determine the content of total lipids and moisture in powdered milk samples. For this, used the near-infrared spectroscopy by diffuse reflectance, combined with multivariate calibration. Initially, the spectral data were submitted to correction of multiplicative light scattering (MSC) and Savitzsky-Golay smoothing. Then, the samples were divided into subgroups by application of hierarchical clustering analysis of the classes (HCA) and Ward Linkage criterion. Thus, it became possible to build regression models by partial least squares (PLS) that allowed the calibration and prediction of the content total lipid and moisture, based on the values obtained by the reference methods of Soxhlet and 105 ° C, respectively . Therefore, conclude that the NIR had a good performance for the quantification of samples of powdered milk, mainly by minimizing the analysis time, not destruction of the samples and not waste. Prediction models for determination of total lipids correlated (R) of 0.9955, RMSEP of 0.8952, therefore the average error between the Soxhlet and NIR was ± 0.70%, while the model prediction to content moisture correlated (R) of 0.9184, RMSEP, 0.3778 and error of ± 0.76%
Resumo:
The aim of this study was to evaluate the potential of near-infrared reflectance spectroscopy (NIRS) as a rapid and non-destructive method to determine the soluble solid content (SSC), pH and titratable acidity of intact plums. Samples of plum with a total solids content ranging from 5.7 to 15%, pH from 2.72 to 3.84 and titratable acidity from 0.88 a 3.6% were collected from supermarkets in Natal-Brazil, and NIR spectra were acquired in the 714 2500 nm range. A comparison of several multivariate calibration techniques with respect to several pre-processing data and variable selection algorithms, such as interval Partial Least Squares (iPLS), genetic algorithm (GA), successive projections algorithm (SPA) and ordered predictors selection (OPS), was performed. Validation models for SSC, pH and titratable acidity had a coefficient of correlation (R) of 0.95 0.90 and 0.80, as well as a root mean square error of prediction (RMSEP) of 0.45ºBrix, 0.07 and 0.40%, respectively. From these results, it can be concluded that NIR spectroscopy can be used as a non-destructive alternative for measuring the SSC, pH and titratable acidity in plums
Resumo:
In this work a study was done using electrochemical cyclic voltammetry and differential pulse voltammetry for isoniazida (INH), ethambutol (EMB), rifampicina (RIF) and pyrazinamide (PZA) using the electrode boron-doped diamond (BDD) as working electrode. It also verified the applicability of the technique of differential pulse voltammetry in the quantification of the active compounds used in the treatment of tuberculosis, subsequently applying in samples of pharmaceutical formulation. Among the four active compounds studied, isoniazid showed the best results for the detection and quantification using differential pulse voltammetry. At pH 4 and pH 8, for the calibration curves to INH showed good linearity, with quantification limits of 6.15 mmol L-1 (0,844 ppm) and 4.08 mmol L-1 (0.560 ppm) for the respective pH. The proposed method can be used to determine drug isoniazid, for recovery values were obtained in approximately 100%
Resumo:
The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
Resumo:
Shadows and illumination play an important role when generating a realistic scene in computer graphics. Most of the Augmented Reality (AR) systems track markers placed in a real scene and retrieve their position and orientation to serve as a frame of reference for added computer generated content, thereby producing an augmented scene. Realistic depiction of augmented content with coherent visual cues is a desired goal in many AR applications. However, rendering an augmented scene with realistic illumination is a complex task. Many existent approaches rely on a non automated pre-processing phase to retrieve illumination parameters from the scene. Other techniques rely on specific markers that contain light probes to perform environment lighting estimation. This study aims at designing a method to create AR applications with coherent illumination and shadows, using a textured cuboid marker, that does not require a training phase to provide lighting information. Such marker may be easily found in common environments: most of product packaging satisfies such characteristics. Thus, we propose a way to estimate a directional light configuration using multiple texture tracking to render AR scenes in a realistic fashion. We also propose a novel feature descriptor that is used to perform multiple texture tracking. Our descriptor is an extension of the binary descriptor, named discrete descriptor, and outperforms current state-of-the-art methods in speed, while maintaining their accuracy.
Resumo:
This work was developed with the objective of proposing a simple, fast and versatile methodological routine using near-infrared spectroscopy (NIR) combined with multivariate analysis for the determination of ash content, moisture, protein and total lipids present in the gray shrimp (Litopenaeus vannamei ) which is conventionally performed gravimetrically after ashing at 550 ° C gravimetrically after drying at 105 ° C for the determination of moisture gravimetrically after a Soxhlet extraction using volumetric and after digestion and distillation Kjedhal respectively. Was first collected the spectra of 63 samples processed boiled shrimp Litopenaeus vannamei species. Then, the determinations by conventional standard methods were carried out. The spectra centered average underwent multiplicative scattering correction of light, smoothing Saviztky-Golay 15 points and first derivative, eliminated the noisy region, the working range was from 1100,36 to 2502,37 nm. Thus, the PLS models for predicting ash showed R 0,9471; 0,1017 and RMSEP RMSEC 0,1548; Moisture R was 0,9241; 2,5483 and RMSEP RMSEC 4,1979; R protein to 0,9201; 1,9391 and RMSEP RMSEC 2,7066; for lipids R 0,8801; 0,2827 and RMSEP RMSEC 0,2329 So that the results showed that the relative errors found between the reference method and the NIR were small and satisfactory. These results are an excellent indication that you can use the NIR to these analyzes, which is quite advantageous, since conventional techniques are time consuming, they spend a lot of reagents and involve a number of professionals, which requires a reasonable runtime while after the validation of the methodology execution using NIR reduces all this time to a few minutes, saving reagents, time and without waste generation, and that this is a non-destructive technique.
Resumo:
Epidemiological surveys are important for obtaining information on the prevalence and etiology of mouth diseases, since the data collected permit health actions to be planned, performed, and assessed. Methodological uniformity is necessary, however, to maintain reproductibility, validity, and reliability, and to allow national and international comparisons. The initiative of the World Health Organization (WHO) as an advisor in ongoing surveys has been extremely useful, stimulating standardization in all countries. In 1991, a Portuguese version of the 1987 third edition of Oral Health Surveys - basic methods, an instruction manual for performing epidemiological surveys, was published and became a reference for many parts of Brazil and the World. The present analysis found conflicting points in relation to the sample size, calibration of the examiners, and criteria for evaluating oral health and treatment needs. In conclusion, due to the dynamic characteristics of scientific knowledge and, considering the regional differences in relation to the development of oral diseases, we recommend that proposals for standardizing surveys be checked periodically. Other important issues may have not been detected in this analysis, urging a thorough discussion within the dentistry community as a whole.
Resumo:
Epidemiological surveys are important for obtaining information on the prevalence and etiology of mouth diseases, since the data collected permit health actions to be planned, performed, and assessed. Methodological uniformity is necessary, however, to maintain reproductibility, validity, and reliability, and to allow national and international comparisons. The initiative of the World Health Organization (WHO) as an advisor in ongoing surveys has been extremely useful, stimulating standardization in all countries. In 1991, a Portuguese version of the 1987 third edition of Oral Health Surveys - basic methods, an instruction manual for performing epidemiological surveys, was published and became a reference for many parts of Brazil and the World. The present analysis found conflicting points in relation to the sample size, calibration of the examiners, and criteria for evaluating oral health and treatment needs. In conclusion, due to the dynamic characteristics of scientific knowledge and, considering the regional differences in relation to the development of oral diseases, we recommend that proposals for standardizing surveys be checked periodically. Other important issues may have not been detected in this analysis, urging a thorough discussion within the dentistry community as a whole.
Resumo:
INTRODUCTION: Humanized and quality prenatal and post-partum care is critical to maternal and newborn health, as well as oral health care. Currently, the National Oral Health Policy is aiming at expanding dental care for pregnant women. Thus, the promotion of oral health and attention to prenatal care policies should be integrated; however, there is still limited participation of pregnant women. Thus, it is necessary to verify the knowledge of pregnant women related to oral health, seeking to estimate the quality of dental care provided during prenatal care, being essential for the Family Health strategy to organize personnel, plan costs and to ensure the quality standard of care. OBJECTIVE: To develop and validate a research instrument on the knowledge of pregnant women about their oral health and of their baby. METHOD: This is a construction and validation study with 93 pregnant women in Family Health Units and specialized private clinics in Obstetrics, in the city of Natal / RN. It was authorized by the Onofre Lopes University Hospital Ethics Committee of the Universidade Federal do Rio Grande do Norte (UFRN) under the registration number 421.163/13. The construction of the instrument followed steps so that it was valid, reliable and sensitive: creation and reduction of the items (drafting of the instrument), content validity and testing of the instrument, and hypotheses validation. Once constructed, the instrument was evaluated by experts who suggested modifications. There was consultation with the target population about the new version of the created instrument, which had the instrument validation verified by internal consistency through intra and inter-calibration and test-retest. Next, the hypotheses were validated. A database was built in the Statistical Package for Social Sciences (SPSS), version 22.0. After creating the hypotheses, an association was found for validating the criteria between each of the specific issues for each established criteria, considering a 5% significance level. Data analysis was carried out by describing the absolute and relative frequencies of the variables pertaining to issues relating to their pregnancy knowledge about their oral health and their baby. The Kappa coefficient was used for the calibration process (Inter and Intra-examiner calibration) and Cronbach's alpha coefficient was used to analyze instrument reproducibility (test-retest). In addition, the chi-square test was used to cross the dependent variable with the (dichotomized) independent variables. RESULTS: The intra and inter agreement analysis presented a Kappa coefficient between 0.400 and 1.000. Internal consistency through the analysis showed that 90% of the instrument's questions showed great reliability in the answers (Cronbach α ˃ 0.7). In the investigation of the relationship between the dependent variable (knowledge about oral health) and the independent variables (trimester of pregnancy, education, income and multiparous), it was found that none of these independent variables were significantly associated. All hypotheses had their Ho confirmed. CONCLUSION: The constructed instrument was validated, considering that it showed to be sensitive with good reliability and good accuracy, and therefore can be used to assess pregnant women’s knowledge about their oral health and the oral health of their baby.
Resumo:
INTRODUCTION: Humanized and quality prenatal and post-partum care is critical to maternal and newborn health, as well as oral health care. Currently, the National Oral Health Policy is aiming at expanding dental care for pregnant women. Thus, the promotion of oral health and attention to prenatal care policies should be integrated; however, there is still limited participation of pregnant women. Thus, it is necessary to verify the knowledge of pregnant women related to oral health, seeking to estimate the quality of dental care provided during prenatal care, being essential for the Family Health strategy to organize personnel, plan costs and to ensure the quality standard of care. OBJECTIVE: To develop and validate a research instrument on the knowledge of pregnant women about their oral health and of their baby. METHOD: This is a construction and validation study with 93 pregnant women in Family Health Units and specialized private clinics in Obstetrics, in the city of Natal / RN. It was authorized by the Onofre Lopes University Hospital Ethics Committee of the Universidade Federal do Rio Grande do Norte (UFRN) under the registration number 421.163/13. The construction of the instrument followed steps so that it was valid, reliable and sensitive: creation and reduction of the items (drafting of the instrument), content validity and testing of the instrument, and hypotheses validation. Once constructed, the instrument was evaluated by experts who suggested modifications. There was consultation with the target population about the new version of the created instrument, which had the instrument validation verified by internal consistency through intra and inter-calibration and test-retest. Next, the hypotheses were validated. A database was built in the Statistical Package for Social Sciences (SPSS), version 22.0. After creating the hypotheses, an association was found for validating the criteria between each of the specific issues for each established criteria, considering a 5% significance level. Data analysis was carried out by describing the absolute and relative frequencies of the variables pertaining to issues relating to their pregnancy knowledge about their oral health and their baby. The Kappa coefficient was used for the calibration process (Inter and Intra-examiner calibration) and Cronbach's alpha coefficient was used to analyze instrument reproducibility (test-retest). In addition, the chi-square test was used to cross the dependent variable with the (dichotomized) independent variables. RESULTS: The intra and inter agreement analysis presented a Kappa coefficient between 0.400 and 1.000. Internal consistency through the analysis showed that 90% of the instrument's questions showed great reliability in the answers (Cronbach α ˃ 0.7). In the investigation of the relationship between the dependent variable (knowledge about oral health) and the independent variables (trimester of pregnancy, education, income and multiparous), it was found that none of these independent variables were significantly associated. All hypotheses had their Ho confirmed. CONCLUSION: The constructed instrument was validated, considering that it showed to be sensitive with good reliability and good accuracy, and therefore can be used to assess pregnant women’s knowledge about their oral health and the oral health of their baby.