68 resultados para Disponibilidade e eficiência
Resumo:
The herbal medicine Sanativo® is produced by the Pernambucano Laboratory since 1888 with indications of healing and hemostasis. It is composed of a fluid extract about Piptadenia colubrina, Schinus terebinthifolius, Cereus peruvianus and Physalis angulata. Among the plants in their composition, S. terebinthifolius and P. colubrina have in common phenolic compounds which are assigned most of its pharmacological effects. The tannins, gallic acid and catechin were selected as markers for quality control. The aim of this study was the development and validation of analytical method by HPLC/UV/DAD for the separation and simultaneous quantification of gallic acid (GAC) and catechin (CTQ) in Sanativo®. The chromatographic system was to stationary phase, C-18 RP column, 4,6 x 150 mm (5 mm) under a temperature of 35 ° C, detection at 270 and 210 nm. The mobile phase consisted of 0.05% trifluoroacetic acid and methanol in the proportions 88:12 (v/v), a flow rate of 1 ml/min. The analytical method presented a retention factor of 0.30 and 1.36, tail factor of 1.8 and 1.63 for gallic acid and catechin, respectively, resolution of 18.2, and theoretical plates above 2000. The method validation parameters met the requirements of Resolution n º 899 of May 29, 2003, ANVISA. The correlation coefficient of linear regression analysis for GAC and CTQ from the standard solution was 0.9958 and 0.9973 and when performed from the Sanativo® 0.9973 and 0.9936, the matrix does not interfere in the range 70 to 110 %. The limits of detection and quantification for GAC and CQT were 3.25 and 0.863, and 9.57 and 2.55 mg/mL, respectively. The markers, GAC and CQT, showed repetibility (coefficient of variation of 0.94 % and 2.36 %) and satisfactory recovery (100.02 ± 1.11 % and 101.32 ± 1.36 %). The method has been characterized selective and robust quantification of GAC and CTQ in the Sanativo® and was considered validated
Resumo:
Water production is unavoidable during a petrol well s lifetime. The amount of produced water associated with oil varies a lot. It can reach values which account to 50% in volume up to nearly 100%, at the end of the well s economic life. It could be verified that, once the water reaches the productive wells, there must be a management of this produced water. Its destiny is defined after a precise study, after which the best option is chosen between relieving it into the environment, re-injecting it into the producing container or disposing it into non-producing formations. Whichever option is made by the involved professionals, after the necessary analysis, it shall consider, besides the technical and economical aspects, also the alternatives which entail less environmental impact. The purpose of the present research is to conduct a study about the application of the constitutional principle of efficiency on the instruments worked out by the public administration on water management, specifically the water use licence and charging for the use in the management of water resources applicable to water production at the petrol wells. In this attempt, before entering the proper approach of the efficiency of the mentioned instruments, it was necessary not only bring to light the doctrinal perception about the constitutional principle of administrative efficiency, but also make some considerations concerning to the structure of the national water resources management, set by the Federal Constitution (1988) and the federal legislation (9433/97)
Resumo:
PETROBRAS, a Brazilian oil company, follows principles of public administration and from the Constitutional Amendment 9/95 in Brazil began to compete with other companies with the flexibility of the oil monopoly. In this new model started to use the simplified procedure for bidding so that could compete on equal terms. The ordinance that adopted a simplified procedure for bidding has been the subject of some criticism and lawsuits especially under the Court of Audit and the Supreme Court in Brazil. The analysis of their constitutionality, and the possibility of their use by other group companies is the theme of this work, and for this purpose, permeates through the notions of judicial review in the Brazilian law on the stage of law and economics analysis of the norm, and the principles applicable to PETROBRAS and the devices most frequently asked about the implementation of 2745/98 Decree. For this, the basic issue that should be investigated further is the regulatory power of the Federal Executive and the delegation of powers within the legislature and its conformation to the constitutional regency
Direito à moradia em cidades sustentáveis: parâmetros de políticas públicas habitacionais Natal 2013
Resumo:
The right to housing is included in several international human rights instruments and in Brazilian legal system integrates the constitutional catalog of fundamental social rights (art. 6) and urban development policy (art. 182 and 183). Besides, it is for all federative governments its effectiveness by building programs and improvement of housing conditions and sanitation (art. 23, IX), which justifies the investment in urban planning and public policy of housing affordability because they are tools for achieving this right. Newer strategies in this area have been based on tax incentives, combined with the mortgage as a way to induce the construction of new housing units or reform those in a precarious situation. However, there is still a deficit households and environmental soundness, compounded with the formation of informal settlements. Consequently, we need constant reflections on the issue, in order to identify parameters that actually guide their housing policies in order to meet the constitutional social functions of the city and ensure well-begins of its citizens (art. 182). On the other hand, the intervention of the government in this segment can not only see the availability of the home itself, but also the quality of your extension or surroundings, observing aspects related to environmental sanitation, urban mobility, leisure and services essential health, education and social assistance. It appears that the smoothness and efficiency of a housing policy condition to the concept of adequate housing, in other words, structurally safe, comfortable and environmentally legally legitimate, viable from the extensive coordination with other public policies. Only to compliance with this guideline, it is possible to realize the right to housing in sustainable cities
Resumo:
This work has as an objective analyze the efficiency of producers costs of the irrigation Project Baixo-Açu , and identify the determining factors of this efficiency. To achieve these targets it was estimated, in a first stage, a frontier of costs by the method, non parametric of Data Envelopment Analysis-DEA, and measured the stakes of efficiency producers. On the second stage, it was utilized the Tobit regression pattern, estimating an inefficiency function of costs, and were indentified the associated factors of resources waste. Among the results found it was noticed the existence of a high waste of resources, that represent more than 54% of effective cost. Among the factors with the highest wastes are: energy, herbicides, defensives and chemical fertilizers. In a general way, the producers presented low efficiency level and, only, two, of seventy-five researched, achieved the frontier of costs minimization. These results reveal, in a certain way, that the producers in irrigated fruit growing in the project Baixo-Açu don t seek to minimize the production costs. It was still noticed, that the reduction of resources waste, and this way the inefficiency of costs, is associated with the agriculturalist education, his experience in agriculture, his access to the technical assistance and credit
Resumo:
The overall objective of this study is to analyze the efficiency in the use of resources and the quality of public health in the municipalities of Rio Grande do Norte, from 2004 to 2008. It also seeks to identify the determinants of municipal inefficiency and measure the productivity of public spending on health. To this end, three methods of analysis are used: the DEA, the Malmquist index and the Tobit regression model. Among other findings, it appears that municipalities considered more inefficient in the measurement of expenditure on health make the largest expense in this function. On the other hand, from 2004 to 2008, only 13 municipalities showed an increase in the productivity of public spending. It is also noted that municipalities considered efficient in quality of health, although having more physical and human resources, offer fewer health services to the population. In all, the major determinants of health spending inefficiencies are the variables: age of the mayor, coalition, population density, literacy race and budget revenues. Regarding the inefficiency of the health quality, variables such as: coalition, literacy race have strong influence on this behavior. Thereby, the hypotheses proposed by the study have been fully accepted. In other words, for the efficiency of the quality and health spending it is needed more than resources, i.e., the expenditure shows itself as essential, but not enough, for political and economic aspects also interfere with the performance of spent and in the quality of health care offered to the population
Resumo:
This paper aims to measure the degree of efficiency in the allocation of public resources in education from the FUNDEB in elementary education in the towns of Rio Grande do Norte in 2007 and 2011. To do so, we must determine to evaluate the efficiency in the allocation of public resources in municipal education in the early and last grades of elementary education; verify that the towns that achieved higher levels of efficiency that were allocated the largest volumes of resources in primary education and analyze which towns reached the worst and the best levels of efficiency in the allocation of public resources in education. This is on the assumption that the relation between the educational policies of local governments and concern for efficiency in the allocation of resources in education is limited only to increase spending on education. It is intended from the model of Data Envelopment analysis, (DEA), with Variable Returns to Scale (VRS), estimate the efficiency of spending on education and municipal pubic purging the problem of outliers. Estimations show that the municipalities of Rio Grande do Norte do not allocate their resources in public elementary education efficiently
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The development and refinement of techniques that make simultaneous localization and mapping (SLAM) for an autonomous mobile robot and the building of local 3-D maps from a sequence of images, is widely studied in scientific circles. This work presents a monocular visual SLAM technique based on extended Kalman filter, which uses features found in a sequence of images using the SURF descriptor (Speeded Up Robust Features) and determines which features can be used as marks by a technique based on delayed initialization from 3-D straight lines. For this, only the coordinates of the features found in the image and the intrinsic and extrinsic camera parameters are avaliable. Its possible to determine the position of the marks only on the availability of information of depth. Tests have shown that during the route, the mobile robot detects the presence of characteristics in the images and through a proposed technique for delayed initialization of marks, adds new marks to the state vector of the extended Kalman filter (EKF), after estimating the depth of features. With the estimated position of the marks, it was possible to estimate the updated position of the robot at each step, obtaining good results that demonstrate the effectiveness of monocular visual SLAM system proposed in this paper
Resumo:
The public illumination system of Natal/RN city presents some recurring problems in the aspect of monitoring, since currently is not possible to detect in real time the light bulbs which are on throughout the day, or those which are off or burned out, at night. These factors depreciate the efficiency of the services provided, as well as, the use of energetic resources, because there is energetic waste and, consequently, financial resources that could be applied at the own public system illumination. The purpose of the work is create a prototype in substitution to the currently photoelectric relays used at public illumination, that have the same function, as well others: turn on or off the light bulbs remotely (control flexibility by the use of specifics algorithms supervisory), checking the light bulbs status (on or off) and wireless communication with the system through the ZigBee® protocol. The development steps of this product and the tests carried out are related as a way to validate and justify its use at the public illumination
Resumo:
The technical and economic viability of solar heating for swimming pools is unquestionable, besides there it replaces the high costs and environmental impacts of conventional supply of energy, and it improves an optimization in the pool heating uses. This work applies the principles of the greenhouse effect: advanced thermodynamics, heat retention and equalization of temperature, to optimize the solar heating equipment, reducing the area required by collectors as much as 40% (still estimated value) for commercial collectors, with minor architectural and aesthetic impacts on the environment. It features a solar heating alternative in pools, whose main characteristics: low cost, simplicity in manufacturing and assembly and a faster heating. The system consists of two collectors spiral hoses made of polyethylene with a hundred meters each, and working on a forced flow, with only one pass of the working fluid inside the coils, and is used to pump itself treatment of pool water to obtain the desired flow. One of the collectors will be exposed to direct solar radiation, and the other will be covered by a glass slide and closed laterally, so providing the greenhouse effect. The equipment will be installed in parallel and simultaneously exposed to the sun in order to obtain comparative data on their effectiveness. Will be presented results of thermal tests for this the two cases, with and without transparent cover. Will be demonstrated, by comparison, the thermal, economic and material feasibility of these systems for heating swimming pools.
Resumo:
We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.
Resumo:
The oil industry`s need to produce with maximum efficiency, not to mention the safety and the environment aspects, encourages the optimization of processes. It makes them look for a level of excellence in acquisition of equipment, ensuring the quality without prejudice security of facilities and peoples. Knowing the reliability of equipment and that this stands for a system is fundamental to the production strategy to seeks the maximum return on investment. The reliability analysis techniques have been increasingly applied in the industry as strategy for predicting failures likelihood ensuring the integrity of processes. Some reliability theories underlie the decisions to use stochastic calculations to estimate equipment failure. This dissertation proposes two techniques associating qualitative (through expertise opinion) and quantitative data (European North Sea oil companies fault database, Ored) applied on centrifugal pump to water injection system for secondary oil recovery on two scenarios. The data were processed in reliability commercial software. As a result of hybridization, it was possible to determine the pump life cycle and what impact on production if it fails. The technique guides the best maintenance policy - important tool for strategic decisions on asset management.
Resumo:
The increasing demand for energy and the environment consequences derived from the use of fossil energy, beyond the future scarcity of the oil that currently is the main power plant of the world, it stimulated the research around the production of biodiesel. In this work the synthesis of biodiesel of cotton in the methyl route was carried through, for had been in such a way used catalyst commercial homogeneous, Na-Methylat and the K-Methylat, aiming to the evaluation of the efficiency of them. An experimental planning 23 was elaborated aiming to evaluate the influence of the variable (molar reason oil/alcohol, % of catalyst and temperature) in the process as well as indicating the excellent point of operation in each case. The biodiesel was analyzed by gaseous chromatography, indicating a conversion of 96,79% when used Na-Methylat® as catalytic, and 95,65% when the K-Methylat® was used. Optimum result found with regard to the conversion was obtained at the following conditions: molar reason oil/alcohol (1:8), temperature of 40°C and 1% of catalyst Na-Methylat, reaching a 96,79% conversion, being, therefore, above of the established for the European norm (96.5%). The analysis of regression showed that the only significant effect for a confidence level of 95%, was of the changeable temperature. The variance analysis evidenced that the considered model is fitted quite to the experimental response, being statistically significant; however it does not serve inside for make forecasts of the intervals established for each variable. The best samples were analyzed by infra-red (IR) that identified the strong bands of axial deformation C=O of methylic ester, characterized through analyses physicochemical that had indicated conformity with the norms of the ANP, that with the thermal and rheological analyses had together evidenced that biodiesel can be used as combustible alternative in substitution to diesel
Resumo:
In wastewater treatment, activated sludge systems have been a technology widely applied as secondary treatment. During this step, which has a strong biological aspect, it is necessary to introduce oxygen supply for the maintenance of metabolic activity of the bacteria through the aerators. Aeration devices are responsible for most of the energy consumption in this stage. In this background, the influence of three aeration intensities (atmospheric air flow 3.5, 7.0 and 10.5 L.min-1) and the concentration of dissolved oxygen (DO) on the dimension of activated sludge flocs as well as on the efficiency of organic matter removal were assessed using a traditional activated sludge system which was fed with synthetic domestic wastewater. Samples were taken weekly from the three units that make up the system feed, aeration and storage tank in order to verify the Chemical Oxygen Demand (COD). It was established the process efficiency through a comparison between the initial and final COD. Besides the parameters already mentioned, this monitoring work on activated sludge batch system was also observed by Mixed Liquor Suspend Solids (MLSS), Volatile Suspend Solids (VSS), pH and temperature measures. The results have showed a maximum removal efficiency around 75% in the first aeration sequence and approximately 85% for the second and third one. For the first aeration, the DO concentration remained higher than 3.0 mg.L-1 and a diameter range from 10 to 60 μm was observed. In the second e third sequence, the DO concentration remained higher than 4.0 mg.L-1 with a diameter range of 10 until 200 μm. Although the sequence 1 and 2 have presented similar performances for organic matter removal, the sequence 2 promoted a regular floc size distribution and with lower values of Sludge Volumetric Index (SVI) meaning a better flocculating ability. In addition, the results reaffirmed what the literature has reported: higher DO concentrations produce flocs with greater dimensions