120 resultados para Postos de abastecimento
Resumo:
Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 μg/L, when the maximum allowed by CONAMA Resolution 420 is 5 μg/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 μg/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized
Resumo:
Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 μg/L, when the maximum allowed by CONAMA Resolution 420 is 5 μg/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 μg/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized
Resumo:
This study aimed to describe the spatial and temporal patterns of variation in trophic state and its relation with the structure and dynamics of planktonic community of a large reservoir located in semi-arid tropical region of Northeast Brazil. The reservoir Armando Ribeiro Gonçalves is the biggest reservoir of the Rio Grande do Norte State and is responsible for about 53% of all surface water accumulated in the State. The samples of water and plankton were taken monthly in 10 points distributed throughout the longitudinal axis of the reservoir and over a full hydrological cycle. The samples were collected to determine concentrations of total phosphorus, total nitrogen, chlorophyll a and suspended solids (fixed and volatile) and for determining the composition and abundance of phytoplanktonic and zooplanktonic species. During the study period, the reservoir was characterized as eutrophic and there was no trend of increasing the trophic state of the reservoir in the period of drought. The concentrations of total phosphorus and suspended fixed solids decreased towards the dam while the N:P ratios increased in the same direction due to the reduction in the phosphorus concentrations and relative constancy in the nitrogen concentrations. The N:P ratios observed were indicative of greater limitation by phosphorus than by nitrogen. However, as concentrations of both nutrients were high and the water transparency was very low, with secchi depth usually lower than one meter, it seems likely that the planktonic primary production of the reservoir is more limited by the availability of light than the availability of nutrients. High nutrient concentrations coupled with low availability of light may explain the continuing dominance of filamentous cyanobacteria such as Cylindrospermopsis raciborskii in the plankton of the reservoir.These cyanobacteria are potentially toxic and pose a serious environmental problem because it compromises the water quality for public supply, recreation and fishing when present in high densities as in this study. The mesozooplankton of the reservoir was dominated by the calanoid Notodiaptomus cearensis and the cladoceran Diaphanosoma spinulosum. In general, the structure of zooplankton community seems to be particularly influenced by the spatial variation of cyanobacteria. The results of the regression analyses show that both the chlorophyll a concentrations and the cyanobacteria biovolume were more strongly correlated with the nitrogen than with phosphorus and that the water transparency was more strongly correlated with algal biomass than with other sources of turbidity. The maximum load of phosphorus to attain the maximum permissible concentration of total P in the reservoir was estimated in 63.2 tonnes P/ year. The current external P load to the reservoir is estimated in 324 tonnes P / year and must be severely reduced to improve the water quality for water supply and allow the implementation of aquaculture projects that could contribute to the socio-economic development of the region
Resumo:
Guaraíras lagoon, located in Tibau do Sul in the eastern littoral of Rio Grande do Norte (Brazil), presents a permanent connection to the sea, which guarantees the occurrence of a rich biodiversity, which includes the autochthonous shrimp species Litopenaeus schmitti, Farfantepenaeus subtilis and Farfantepenaeus brasiliensis. In spite of being subject to a strong human intervention in the last decade, mainly related to the installation of shrimp (Litopenaeus vannamei) farms, the lagoon is still scarcely studied. The present study aims at characterizing the populations of the three autochthonous penaeid shrimp species inhabiting Guaraíras, taking into consideration their abundance and seasonal distribution in the inflow channel of Primar System of Organic Aquaculture (Tibau do Sul, Rio Grande do Norte, Brazil). Twelve monthly samples were carried out from May 2005 to April 2006 with the aid of a circular cast net in the inflow channel, which is daily supplied with water from Guaraíras. Sampling months were grouped in trimesters according to the total pluviosity, thus comprising four trimesters. Water salinity was monitored twice a week and temperature values registered on a daily basis at noon, during the study period. The daily pluviosity data from the municipality of Tibau do Sul were supplied by Empresa de Pesquisa Agropecuária do Rio Grande do Norte (EMPARN). Collected shrimp were identified, weighted, measured and sexed. L. schmitti specimens (0.2 g to 17.8 g) were distributed in 1.3 g weight classes intervals. From the eighth sampling month (December 2005) onwards, males were classified into three categories, in accordance with the development of their petasm: (a) rudimentary petasm, (b) partially formed petasm, and (c) completely formed petasm. Among the ecological variables, rainfall showed the greatest dispersion (s.d.=187.74Rainfall and abundance of L. schmitti were negatively correlated (r = -0.85) whereas its abundance and water salinity were positively correlated (r = 0.63). Among 1,144 collected individuals, 1,127 were L. schmitti, 13 were F. subtilis and 4 were F. brasiliensis, which corresponded to 98.51%, 1.14% and 0.35% of the total of collected individuals. L. schmitti occurred in 100 % of all samples. Differently, the presence of F. subtilis and F. brasiliensis was restricted to 33% and 17% of the collected samples, respectively. The present study confirmed the occurrence of L. schmitti, F. brasiliensis and F. subtilis in Guaraíras. However, this lagoon seems to be primarily inhabited by juvenile Litopenaeus schmitti. The population of L. schmitti analysed showed a seasonal pattern of distribution. In general, in the months of high salinity and absence of rain, the number of individuals was higher than in the wet months. Further studies on the reproductive biology and ecology of L. schmitti, F. brasiliensis and F. subtilis may elucidate questions referring to the abundance, period, and phase of occurrence of these shrimp genera in Guaraíras. Finally, the risks associated to the establishment of L. vannamei in the lagoon provide a novel outlet for studies in this biotope
Resumo:
The retail fuel stations are partially or potentially polluters and generators of environmental accidents, potentially causing contamination of underground and surface water bodies, soil and air. Leaks in fuel retail stations´ underground storage systems are often detected in Brazil and around the world. Monoaromatic hydrocarbons, BTEX (benzene, toluene, ethylbenzene and xylenes) and polycyclic aromatic hydrocarbons (PAHs) are an indication of the presence of contamination due to its high toxicity. This paper presents a case study of contamination in a Fuel Retail Station by petroleum derivative products in the city of Natal. For identification and quantification of the hydrocarbons, EPA analytical methods were used. The values of benzene quantified by EPA method 8021b CG-PID/FID, ranged from 1.164 to 4.503 mg.Kg-1 in soil samples, and from 12.10 to 27,639 μg.L-1 in underground water samples. Among the PAHs, naphthalene and anthracene showed the most significant results in soil samples, 0.420 to 15.46 mg.Kg-1 and 0.110 to 0,970 mg.Kg-1, respectively. In underground water samples, the results for Naphthalene varied between 0.759 and 614.7 μg.L-1. PAHs were quantified by EPA Method 8270 for GCMS. All of the results for the chemical analysis were compared with the values for the CONAMA 420/2009 resolution. The results for benzene (27,639 μg.L-1) showed levels highly above the recommended by the CONAMA 420 resolution, wherein the maximum permissible for underground water is 5 μg.L-1. This is a worrying factor, since underground water makes up 70% of the city of Natal´s water supply
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The increasing use of fossil fuels in line with cities demographic explosion carries out to huge environmental impact in society. For mitigate these social impacts, regulatory requirements have positively influenced the environmental consciousness of society, as well as, the strategic behavior of businesses. Along with this environmental awareness, the regulatory organs have conquered and formulated new laws to control potentially polluting activities, mostly in the gas stations sector. Seeking for increasing market competitiveness, this sector needs to quickly respond to internal and external pressures, adapting to the new standards required in a strategic way to get the Green Badge . Gas stations have incorporated new strategies to attract and retain new customers whom present increasingly social demand. In the social dimension, these projects help the local economy by generating jobs and income distribution. In this survey, the present research aims to align the social, economic and environmental dimensions to set the sustainable performance indicators at Gas Stations sector in the city of Natal/RN. The Sustainable Balanced Scorecard (SBSC) framework was create with a set of indicators for mapping the production process of gas stations. This mapping aimed at identifying operational inefficiencies through multidimensional indicators. To carry out this research, was developed a system for evaluating the sustainability performance with application of Data Envelopment Analysis (DEA) through a quantitative method approach to detect system s efficiency level. In order to understand the systemic complexity, sub organizational processes were analyzed by the technique Network Data Envelopment Analysis (NDEA) figuring their micro activities to identify and diagnose the real causes of overall inefficiency. The sample size comprised 33 Gas stations and the conceptual model included 15 indicators distributed in the three dimensions of sustainability: social, environmental and economic. These three dimensions were measured by means of classical models DEA-CCR input oriented. To unify performance score of individual dimensions, was designed a unique grouping index based upon two means: arithmetic and weighted. After this, another analysis was performed to measure the four perspectives of SBSC: learning and growth, internal processes, customers, and financial, unifying, by averaging the performance scores. NDEA results showed that no company was assessed with excellence in sustainability performance. Some NDEA higher efficiency Gas Stations proved to be inefficient under certain perspectives of SBSC. In the sequence, a comparative sustainable performance and assessment analyzes among the gas station was done, enabling entrepreneurs evaluate their performance in the market competitors. Diagnoses were also obtained to support the decision making of entrepreneurs in improving the management of organizational resources and promote guidelines the regulators. Finally, the average index of sustainable performance was 69.42%, representing the efforts of the environmental suitability of the Gas station. This results point out a significant awareness of this segment, but it still needs further action to enhance sustainability in the long term
Resumo:
This study approaches the question of the administrative procedure of the environmental licensing of ranks of fuel resale, taking as basis a study case of the reality of the City of Natal/RN (Brazil). For in such a way, it was done a retrospect on the evolution of the system of road transport in Brazil, having started to briefly analyze the urbanization process that if after accented in the capitals of the Brazilian States the decade of 1950, relating these subjects with the growth of the sector of fuel resale. After that, it was transferred boarding of the defense of the national environment to the light of ambient principles constitutional. In the sequence, a boarding on the ambient guardianship in the Federal Constitution of 1988 was made, treating basically specifies and on the national urban politics and the national politics of the environment, with its instruments. In the sequence, it was transferred the analysis of the abilities and attributions of the National Advice of the Environment (CONAMA) and its Resolutions, for then only enter in the most important part of this work: an analysis of the environmental licensing of ranks of fuel resale, in the reality of the City of Natal/RN. Before this specific boarding, it was proceeded specifically a survey and communication from the applicable norms to such establishments (Resolutions of the CONAMA and norms of the ABNT), for after that carrying through an geo-ambient characterization of the City of Natal/RN. Finally, a reflection was made on the possibility of magnifying of the state activity, in terms of guarantees for the responsible members for the environmental policy and of administrative efficiency, through the idea of the ambient regulation. For the accomplishment of this study, it was proceeded research in diverse sources such as books, magazines, sites of the Internet, periodicals, thesis and dissertations, among others material, beyond visits the agencies that direct or indirectly act with the ambient defense and as fuel resale, such as Secretariat of Environment and Urbanism of the City of Natal (SEMURB), Institute of Economic Development and Environment of RN (IDEMA), Brazilian Institute of the Environment and the Natural resources You renewed, Executive Management of RN (IBAMA/RN), Public prosecutor's office of the Environment of Natal (Public prosecution service of the RN), National Agency of Oil (ANP) and Union of the Retailing of Derivatives of Oil of the RN, among others. To the end, satiated regulation is observed that although on the substance of the ambient licensing in ranks of fuel resale, also with federal, state and municipal norms, the municipal Public Power is very far from the fulfilment of its institutional functions, in the question environmental policy of these establishments, a time that few are the permitted ranks of resale in the city of Natal/RN
Resumo:
Infrastructure works are included in strategic areas for the social development. For that matter that all of the investments are very important for the social development. When the population has enough water and an acceptable quality, and it includes a wastewater gathering and its treatment, the whole society became less susceptible to the water diseases. Even the Water Supply and the Sewage depend for its perfect operation of reservoirs, or of the accumulation of water to provide the popular necessity, either due to retention or for the treatment wastewarer. These structures present very specific environmental conditions, because the microclimate created around them, like high environmental humidity and for the existence of many harmful substances for the concrete, such as chloride ions presents in water. The reservoir that compose the System of Water Supply of Natal were built between 1970s and 1980s, a period whom the technical and scientific community did not have in-depth studies about the reinforced concrete mechanism of deterioration. Therefore, these reservoirs have been suffered accelerated deterioration progress, and they have been shown many pathological manifestations strikingly visible. In front of all these problems this academic work aims to identify the generally conditions of conservation of all the reservoirs components of the Water Supply System of Natal. This academic work objectives to develop a recuperation plan for use in these reservoirs, in this academic work it was achieved all the survey of pathological manifestation existing in each reservoir. It was made with local visits, photographic recorders of all manifestations viii and realization of in loco tests. The other step consisted in a application of GDE/UnB metodolgy reformulated by Fonseca (2007). In the step of local visits in each reservoir it was evaluated carbonation depth, by spreading a phenolphthalein solution with 1% of concentration; evaluation of contamination of chlorides, by spreading silver nitrate solution with 1% of concentration, and evaluation of width cracks. After the conclusion of all the testings, it was established that all reservoir, studied in this academic work, have showed an advanced deteriorating condition. It´s presents prevalent pathological manifestations as unacceptable cracks, spots, efflorescence and reinforcement corrosion, and in some cases, chlorides contamination. After the conclusion of the testings and its concatenation it was able to implementing, using GDE/UnB methodology, the order of the restoration its service life and initial safety conditions
Resumo:
A modeling of criterias and alternatives is through and applied a questionnaire based on method AHP to proprietors of gas stations. The considered alternatives had been the maintenance of the current state with electric energy of the deliverer and the generation in small scale based on the natural gas. The used criteria had been Cost of the Investment, Final Cost of the Energy, Operational cost, Ambient Benefits, Risk and Variation of Costs. The study it was carried through in the city of Natal, RN in ranks that make use of the natural as for resale, where the generation alternative on the basis of the available gas is present. The main results evidence in a dimension the viability of use of method AHP with questionnaire by means of validation of the judgments with analysis of variance beyond proper the normal mechanisms of analysis of consistency to the method. The main results of the analysis help to show that in this in case that the profile of models of criteria and judgments of the actors is similar, with the final evidence of that it has a dominance of the maintenance of the energy of the deliverer. The main criterion to influence this decision was the risk
Resumo:
natural resources that still enjoy, in the certainty that if we do not, could culminate at the end of that remains. The environmental contamination by fuels in the retail service of oil and biofuels, has been a subject of growing research in Brazil, due to the large pollution potential of this activity. The aim of this study was to evaluate the importance of implementing the Environmental Management System (EMS) in fuel retail service stations in the city of Parnamirim-RN, but also describe the current situation the same as licensing and environmental characterization; identify existing barriers to implementation of EMS on the costs, technologies, knowledge, vision, present the potential benefits for the implementation of the EMS (social, economic and environmental), to identify the existence of plans for future action to implement the EMS , as a subsidy to promote the implementation of it. The methodology was developed through analysis of documents provided by the environmental agency responsible for licensing of retail service stations and fuel pala ANP. For data collection, we used the questionnaire was applied directly to managers or managers of sub-stations. Data were collected in 12 of 30 posts in the municipality. For purposes of data treatment was performed a descriptive analysis with respect to the opinion of twelve managers (respondents). The data acquired, according to the Likert scale were tabulated and analyzed using software SPSS 17.0 and Excel 2003, it was generated tables and graphs to observe the behavior of the data. The results showed that most respondents have a schooling level higher (58.3%) of the jobs surveyed 50% work on average 6 to 10 years and 41.6% are in operation for over 11 years , 75.0% do not have a license to operate and 12 stations, 58.3% were sued for not having a license to operate and are therefore in full commercial activity, 83% of jobs have some practice environmentally responsible, 75% agree in making planning future action to implement 8 the EMS in their ventures, 70% in full agreement that the high cost is a form of impediment to implementation of EMS; 66.67% agreed that resistance to change is an impediment to implementation of EMS; 90.91% agreed that the implementation of EMS is very complex, 80% of respondents agreed in a very significant environmental legislation is also a key factor preventing the implementation of EMS is noteworthy that 100% of respondents agreed that the knowledge about the use of the EMS will help to solve environmental problems in the fuel retail service stations, the implementation of the EMS will benefit with increased efficiency of resources applied to the findings by the agreement of 91.66% of respondents, where only 8, 33% disagreed, there was also a percentage of 100%, agreed that the company's image will be a great benefit, but also a contribution to solving environmental problems in the fuel retail service stations. Thus, the importance of the implementation of EMS in the fuel retail service stations in the city of Parnamirim-RN, with an urgent need to be deployed. And the bodies responsible for policy on state-run and supervise more tightly and action, this type of activity, in order to regulate the sustainable functioning of retail service stations of fuel, thus promoting a better quality of life for the population of the municipality of natal-RN
Resumo:
The objective of this work was to investigate the factors that inhibit the use of Environmental Techniques in the Gas Station of the city of Natal/RN. For this, a survey with the aid of a questionnaire was used like research instrument. It s used a sample for convenience, not probabilistic. For collection of the data, it was used directly application of the questionnaire to the Managers or Assistant managers of the gas station, in accordance with its availability or presence. The data was collected in all the regions of Natal (North, South, East and West). The population in accordance with the data of the ANP of September 2005 is of 111 ranks and the collected sample was of 86. To carry through the analysis of the data of this research had been used softwares Excel and Statistic version 5.0, for Windows. The analysis of data is divided in two parts; descriptive analysis and analysis of groupings (clusters). The results showed that bigger part of the interviewed ones has between 30 and 39 years of age; they have second grade completed; they had declared to have little between and reasonable knowledge how much to the use of Clean Technology (CT) in gas station; and a small part of the interviewed ones had informed to have much knowledge how much the resolutions of the CONAMA established for the Gas Station. Of the searched ranks, the majority is national(76.7%); the most accurate practice environmental used in the gas station are: it collects selective of oil used or contaminated and ecological tanks - coated with strengthened fibre glass; great part of the interviewed ones (33.8%) informed that never the TL makes planning of referring future action; about of the half of the interviewed ones (84.9%) they had more declared that its employees have of none to a reasonable level of training for deal with problems that compromise the environment; the majority of the ranks (72.1%) functions has for more then six years. It is observed that almost all the interviewed ones (96.5%) evaluate as being important or very important the implantation of CT in Gas Station and the great majority (82.1%) evaluates the difficulty in if implanting these technologies in Gas Station as being easy or very easy. In the analysis of cluster, it was verified existence of two groupings (as much in the variable of the barriers and benefits), being that inside of each clusters exists homogeneity and between clusters exists heterogeneity. In reality, everything is important or very important in the opinion of the interviewed ones. There only exists a small significant difference that separates them in clusters
Resumo:
The customer loyalty became strategy factor for the sustainability of business enterprises. And will be them competitive is important to describe the factors than the consumers consider for to choose the business than will buy the product or service. The dissertation objective is to know the factors that influence the consumer s satisfaction and loyalty in gas stations of Natal/RN, using the index national of customer satisfaction. The literature review was directed for strategy concepts, service quality, satisfaction and fidelity consumer and index national of customer satisfaction. The method used was descriptive-explicative, with application of a survey, from march 15 until april 15 of 2013, with 391 consumers of gas station. In relational analysis, we considered eight constructs: quality, price, complaints, satisfaction, image, loyalty, affection and commitment calculated. For customer satisfaction, the factors that influence have resulted in fuel quality, technical skills of vendors and duration of service. For customer loyalty, the factors that influence resulted in: image, feeling for distributor flag post, location and overall satisfaction with the gas station
Resumo:
The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research
Resumo:
This work presents the analysis of data collected by Universidade Federal do Rio Grande do Norte and State Public Prosecution Office experts concerning to current situation of liquid fuel resale stations, its forms of storage and its technical apparatus for the performance of primary functions (supply of vehicles) and secondary (car washing, storage of used oil, oil change etc.). The data presented were analyzed in the setting of the city of Natal (RN) and considering its characteristics, potentialities and weaknesses. Thereafter, it was discussed liquid fuels resale pollution potential in the city and legal provisions directed to implementation of Green Seal. The discussion involves three agents: environmental, legal and technical ones, applied to all 110 resale fuel stations which were analyzed