54 resultados para Passive heating

em Deakin Research Online - Australia


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The literature over the past 25 years indicates that there has been a continued interest in using passive and active solar technologies to reduce the conventional energy required to maintain water temperatures in small recirculation aquaculture systems. Although all of the experimental systems reviewed report favourable results, there is little information available to guide system designers. This paper describes the use of a simulation model to predict the annual conventional energy consumption of a 10.6 m3 RAS enclosed in a double layer polyethylene greenhouse in two different climates. The water was maintained at 22.5 °C and the recirculation rate was 10% of tank volume per day. Simple unglazed solar collectors have also been combined with the greenhouse to further reduce energy consumption. The effect of increasing collector area on the solar fraction and utilization of useful energy was predicted. Finally, the model was used to investigate the relationship between the occurrence of condensation on the inner cover, ventilation rates and energy use. It was found that in a hot dry climate, the greenhouse alone was sufficient to reduce the conventional energy requirements by 87%; while in the cooler temperate climate reductions of 66% were possible. When solar collectors were added to the system, conventional energy requirements were reduced further and depended on the area of collector used. For example, in the temperate climate location, conventional energy requirements were reduced to 23% of a RAS enclosed in a non-solar building when 26 m2 of solar collector inclined at the optimum angle for winter energy collection were used. Although condensation could be successfully reduced by ventilation of the greenhouse, this increased conventional energy requirements because the potential for evaporation was increased. Covering the tanks at night was found to be a more effective strategy because it reduced condensation and conventional energy use simultaneously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A practical experiment is described which was used to help university students increase their understanding of the effect of construction methods and window design on passive solar heating and electrical heating. A number of one tenth scale model rooms were constructed by students and sited out-of-doors in the late autumn. The models were fabricated to mimic available commercial construction techniques with careful consideration being given to window size and placement for solar access. Each model had a thermostatically controlled electric heating element. The temperatures and electricity use of the models were recorded using data-loggers over a two week period. The performances of the models based on energy consumption and internal temperature were compared with each other and with predictions based upon thermal mass and R-values. Examples of questions used by students to facilitate this process are included. The effect of scaling on thermal properties was analysed using Buckingham’s p-theorem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By coating textiles with electrically conductive organic polymers, we are able to produce functional, intelligent fabrics. These fabrics can be utilised in applications such as gas sensors, actuators, electromagnetic shielding, radar absorption, selected frequency filtering in indoor wireless applications, and heating applications where vital parts of the body can be heated without embedding any wiring through the fabric.

Heat generation in fabrics coated with the conductive polymer polypyrrole was investigated. The fabrics were coated by chemical synthesis methods by oxidizing the pyrrole monomer in the presence of the fabric substrate. Ferric chloride was selected as the oxidizing agent and anthraquinone-2-sulfonic acid (AQSA) sodium salt monohydrate as the dopant.

Conductive fabrics were characterized by resistivity measurements, scanning electron microscopy, thermal imaging, current transmission over a period of time and calculations of power density per unit area. Effects of reaction conditions on the electrical properties and heat generated are presented. Polypyrrole coated fabrics were stable and possessed high electrical conductivity. Resistivity values ranged from 100-500 ohms/square depending on the reaction parameters. When subjected to a constant voltage of 24V, the polypyrrole coated polyester-Lycra® fabric doped with AQSA reached a maximum temperature of 42°C and a power density per unit area of 430 W/m2 was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alternant heat transfer induced by particle packet and gas bubbles on an object surface in a gas fluidised bed is computationally studied. The particle packet and bubble are modelled by a DPPM (double particle-layer and Porous Medium) model and a hemispherical model, respectively. Different meshing schemes are applied and different mesh sizes are used in meshing particle packet and heated object and a very large geometrical size difference between them was considered. Two parallel solver processes were proposed to perform the simulation of heat transfer for different purposes and implemented with the Fluent CFD package.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we discuss the ghost node problem found when triangulation of 2 or more nodes is required. We present and discuss a simple algorithm, termed ABLE (Angle Based Location Estimation), that will position randomly placed emitters in a wireless sensor network using a mobile antenna array. The individual nodes in the network are relieved of the localization task by the mobile antenna system and require no modifications to account for location determination. Furthermore, no beacon nodes (i.e. nodes that know their own position) are required. We provide analysis that indicates a reasonably small number of measurements are required to guarantee the successful
localization of the emitting nodes and demonstrate our results through simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we examine the geometric relations between various measured parameters and their corresponding errors in angle-measurement based emitter localization scenarios. We derive a geometric constraint formulating the relationship among the measurement errors in such a scenario. Using this constraint, we formulate the localization task as a constrained optimization problem that can be performed on the measurements in order to provide the optimal values such that the solution is consistent with the underlying geometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we characterize the relative sensor-target geometry for bearing-only localization in R2. We analyze the geometry in terms of the Cramer-Rao inequality and the corresponding Fisher information matrix, aiming to characterize and state explicit results in terms of the potential localization performance. In particular, a number of interesting results are rigorously derived which highlight erroneous assumptions often made in the existing literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we characterize the relative sensor-target geometry in R2 in terms of potential localization performance for time-of-arrival based localization. Our aim is to characterize those relative sensor-target geometries which minimize the relative Cramer-Rao lower bound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of civil aerospace composites is key to future “greener” aircraft. Aircraft manufacturers must improve efficiency of their product and manufacturing processes to remain viable. The aerospace industry is undergoing a materials revolution in the design and manufacture of composite airframes. The Airbus A350 and Boeing 787 (both due to enter service in the latter part of this decade) will push utilisation levels of  composite materials beyond 50% of the total airframe by weight. This  change requires massive investment in materials technology, manufacturing capability and skills development. The Quickstep process provides the ability to rapidly cure aerospace standard composite materials whilst providing enhanced mechanical properties. Utilising fluid to transfer heat to the   composite component during the curing process allows far higher heat rates than with conventional cure techniques. The rapid heat-up rates reduce the viscosity of the resin system greatly to provide a longer processing window introducing greater flexibility and removing the need for high pressure during cure. Interlaminar fracture toughness (Mode I) and Interfacial Shear Strength of aerospace standard materials cured using Quickstep have been    compared to autoclave cured laminates. Results suggest an improvement in fibre-matrix adhesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wildfires can induce or enhance soil water repellency under a range of vegetation communities. According to mainly USA-based laboratory studies, repellency is eliminated at a maximum soil temperature (T) of 280–400°C. Knowledge of T reached during a wildfire is important in evaluating post-fire soil physical properties, fertility and seedbed status. T is, however, notoriously difficult to ascertain retrospectively and often based on indicative observations with a large potential error. Soils under fire-prone Australian eucalypt forests tend to be water repellent when dry or moderately moist even if long unburnt. This study aims to quantify the temperature of water repellency destruction for Australian topsoil material sampled under three sites with contrasting eucalypt cover (Eucalyptus sieberi, E. ovata and E. baxteri). Soil water repellency was present prior to heating in all samples, increased during heating, but was abruptly eliminated at a specific T between 260 and 340°C. Elimination temperature varied somewhat between samples, but was found to be dependent on heating duration, with longest duration resulting in lowest elimination temperature. Results suggest that post-fire water repellency may be used as an aid in hindcasting soil temperature reached during the passage of a fire within repellency-prone environments.


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyethyleneterephtalate–polypyrrole (PET–PPy) textile complexes incorporating different anionic dopants have been heat treated at 60 °C, 80 °C, 105 °C, 125 °C and 150 °C to investigate effects of short-term heating on conductivity and stability. In most cases heat treatments below 80 °C did not significantly change the final resistance of the conducting textiles. Only the anionic dye-dopant Indigo Carmine acted in a heat-stabilizing manner during treatment at 150 °C, while all samples containing other anionic dopant underwent some degradation. A treatment temperature of 125 °C was the most effective for lowering the final resistance, with sulphonic group containing dopants being particularly effective in improving conductivity and stability. A 29% decrease in the final resistance of a PET–PPy/para-toluene-2-sulphonic acid (pTSA) sample was achievable after 900 s at 125 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passive flow is believed to increase the gains and reduce the costs of active suspension feeding. We used a mixture of field and laboratory experiments to evaluate whether the unstalked intertidal ascidian Pyura stolonifera exploits passive flow. We predicted that its orientation to prevailing currents and the arrangement of its siphons would induce passive flow due to dynamic pressure at the inhalant siphon, as well as by the Bernoulli effect or viscous entrainment associated with different fluid velocities at each siphon, or by both mechanisms. The orientation of P. stolonifera at several locations along the Sydney-Illawarra coast (Australia) covering a wide range of wave exposures was nonrandom and revealed that the ascidians were con- sistently oriented with their inhalant siphons directed into the waves or backwash. Flume experiments using wax mod- els demonstrated that the arrangement of the siphons could induce passive flow and that passive flow was greatest when the inhalant siphon was oriented into the flow. Field exper- iments using transplanted animals confirmed that such an orientation resulted in ascidians gaining food at greater rates, as measured by fecal production, than when oriented perpendicular to the wave direction. We conclude that P. stolonifera enhances suspension feeding by inducing pas- sive flow and is, therefore, a facultatively active suspension feeder. Furthermore, we argue that it is likely that many other active suspension feeders utilize passive flow and, therefore, measurements of their clearance rates should be made under appropriate conditions of flow to gain ecolog- ically relevant results.