55 resultados para DC system efficiency


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite Information Communication Technology (ICT) can help to improve efficiency and Enterprise Resource Planning (ERP) system has been widely perceives as an efficient mean, diffusion rate is slow in construction industry and amongst quantity surveying profession. Today, quantity surveyor must frequently communicate with other stakeholder throughout the design and construct process and using information technology is a must. The more technologies evolve, the more quantity surveying with change and evolve to utilize these technologies. This paper, through literature review, firstly identifies perceived benefits of using ICT/ERP system, secondly concludes the critical success factors that may affect decision of adopting ICT/ERP tool in practice, and thirdly to suggest three effective evaluation tools before/after implementing ICT/ERP strategy. The ultimate goal is to advise how Australian quantity surveyors (QS) can utilize ICT and ERP system to improve efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three kinds of titania/silica pellets were prepared using the sol-gel method with surface areas of 50.4m2 g-1, 421.1m2.g-1 and 89.1m2.g-1. An annular reactor was designed and built to determine the degradation efficiency of toluene and to investigate the relationship between the adsorption and desorption-photocatalytic processes. Surface area is an important factor influencing the adsorption-photocatalytic efficiency. Higher surface areas of pellets contribute to high rates of conversion of toluene. Un-reacted toluene and reaction intermediates accumulating on their surface deactivated the titania/silica catalyst. To overcome this problem, the adsorption and regeneration process were alternated in a dual reactor system. Connecting or disconnecting the toluene feed gas enabled one reactor to adsorb toluene, while the second reactor was regenerated by photocatalysis. Using UV irradiation and titania/silica pellets with high BET surface area (421.1 m2.g-1), the alternating adsorption/regeneration processes kept the degradation efficiency of toluene at 90% after 8 hours operation. By improving the adsorption-photocatalysis efficiency, and minimising the generation and accumulation of intermediate on the surface of pellets, the method extended catalyst life and maintained a high degradation efficiency of toluene.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper conducts productivity and efficiency analysis of banks operating in Australia since the deregulation of the Australian financial system in early 1980s. Applying data envelopment analysis (DEA), with a moving window, the Malmquist indices are determined in order to investigate the levels of and the changes in the efficiency of Australian banks over the period from 1983 to 200 I. The DEA window analysis is adopted in order to relieve the small sample problem that in previous studies has proved problematic in the study of the Australian banking sector. The pal1icular window used in this case has been carefully designed to ensure the robustness of the efficiencies scores to changes in the window width. A second-stage regression is conducted by using the unconditional bootstrap approach suggested by Xue and Harker (1999) to overcome the dependency and heteroskedasticity of DE A efficiency scores. The empirical results demonstrate the effect of deregulation on the performance of individual banks, banks of different organizational types and the entire Australian banking sector.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2′-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Against the background of increasing competition from globalization and the trend towards consolidation, diversification and rationalization, the study of efficiency is most relevant in the Malaysian Islamic banking context, where all domestic commercial banks operate Islamic banking schemes. Using the non-parametric method of Data Envelopment Analysis (DEA), this study investigates the recent efficiency of the Malaysian Islamic Banking system. The attributions of technical efficiency (utilization of capacity) and scale efficiency (optimality of scale achieved) are identified. Further, Islamic Banking Schemes operating under the dual banking system of foreign and domestic commercial banks were benchmarked to the country's two full-fledged Islamic banks to provide insight of the relative efficiencies. Amidst an overall improvement in TE and SE, it was noted that foreign banks (FB) increased efficiency levels to achieve full efficiency over the six-year period, and domestic banks (DB) followed by smaller improvement while the fully-fledged Islamic banks (FFIE) experienced a general decline in efficiency which was solely attributed to scale inefficiency. The findings provide useful guidelines for policy implications and may also assist banks concerned with their strategic planning with regard to the future of Islamic banking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High pressure die casting (HPDC) is a versatile process for producing engineered metal parts by forcing molten metal under high pressure into reusable steel dies. However there are a large number of attributes involved which contribute to the complexity of the process. A novel integrated approach is developed to optimize the high pressure die casting processes. The die temperature profiles will be studied with infrared thermograph technology and the internal cooling system will be optimized to provide even cooling to the components and the die. The heat stored in the die and the components is studied with image processing. Based on the geometrical profile of the components, cooling channels can be redesigned to improve the cooling efficiency while the cooling time is reduced. This will not only significantly improve the quality of the castings but also improve the productivity of the process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implementation and certification of Environmental Management Systems (EMS) is a reality for many businesses. Communication with an organisation’s stakeholders is a required element of any EMS. In the last five years companies have steadily moved towards integrating their different management systems, such as quality, environmental, and occupational health and safety, in an attempt to reduce their costs and increase efficiency. Legislation requires extensive reporting in each of these areas, so compliance is another important driver. During this period, communication by digital technology, or electronic communication, has gained prominence and acceptance amongst all groups of people including businesses primarily as a means to disseminate crucial EMS information to geographically diverse employees in a cost effective and instantaneous manner. Some perspectives have emerged to suggest that change processes in organisations may be hindered or helped in various ways through the application of digital technology in EMS. There are, however, gaps in the literature that document the impact and effectiveness of electronic communication amongst EMS stakeholders. In this paper we will discuss employees as one of the major stakeholders and whether the move to electronic communication has been assisting or hindering transformations in awareness and understanding of issues amongst employees. We highlight opportunities and challenges presented by an increased use of electronic communication in light of the environmental and climate change debates, which underpin EMS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of electricity in buildings constitutes around 16% of Singapore's energy demand. In view of the fact that Singapore is an urban city with no rural base, which depends heavily on air-conditioning to cool its buildings all year round, the survival as a nation depends on its ability to excel economically. To incorporate energy efficiency measures is one of the key missions to ensure that the economy is sustainable. The recently launched building energy efficiency labelling programme is such an initiative. Buildings whose energy performance are among the nation's top 25% and maintain a healthy and productive indoor environment as well as uphold a minimum performance for different systems can qualify to attain the Energy Smart Office Label. Detailed methodologies of the labelling process as well as the performance standards are elaborated. The main strengths of this system namely a rigorous benchmarking database and an independent audit conducted by a private accredited Energy Service Company (ESCO) are highlighted. A few buildings were awarded the Energy Smart Office Label during the launching of the programme conducted in December 2005. The labeling of other types of buildings like hotels, schools, hospitals, etc. is ongoing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrical data of two quay cranes, one has a DC drive system and the other has an AC drive system, in actual working conditions at a container terminal are measured and presented in this paper. Peak demand, energy usage, power factor and power quality are examined and compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An intelligent energy management system (IEMS) is developed to improve fuel efficiency of an internal combustion engine vehicle. It helps determine the best approach to run the engine system through dynamically analysing various factors relating to vehicle. The energy balance technique is implemented and utilised. The simulation outcome of the IEMS is compared against that of a conventional system under the same driving factors. The results show that the IEMS reduces the fuel consumption around 5.6% for the tested conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The dynamic characteristics of gas bubbles in fluidized beds are important to determine the heat and mass transfer rates at component surfaces and the treated profiles of components. They also have great impact on the components’ structural, mechanical and physical properties. However, it has been very difficult to monitor those characteristics dynamically. In this paper, a specifically designed fluidized bed was introduced to facilitate the capturing of its dynamic characteristics and a new video image processing and analysis algorithm was developed. The algorithm is robust and adaptive in terms of locating both bubbles and components in beds with a single or multiple components. It has many advantages in dynamic characterization of gas bubbles and monitoring component treatment. By using this algorithm, the properties of gas bubbles over any period of time can be accurately obtained. This technology will provide a potential on-line dynamic monitoring and quality control system for the chemical heat treatment processes with fluidized beds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water shortage is a major problem facing the power industry in many nations around the world. The largest consumer of water in most power plants is the wet cooling tower. To assist water and energy saving for thermal power stations using conventional evaporative wet cooling towers, a hybrid cooling system is proposed in this paper. The hybrid cooling system may consists of all or some of an air pre-cooler, heat pump, heat exchangers, and adsorption chillers together with the existing cooling tower. The hybrid cooling system described in the paper, consisting of a metal hydride heat pump operating in conjunction with the existing wet cooling tower, is capable of achieving water saving by reducing the temperature of warm water entering the cooling tower. Cooler inlet water temperatures effectively reduce the cooling load on existing towers. This will ultimately reduce the amount of water lost to the air by evaporation whilst still achieving the same cooling output. At the same time, the low grade waste energy upgraded by the metal hydride heat pump, in the process of cooling the water, can be used to replace the bleed of steam for the lower stage feed heaters which will increase overall cycle efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Identifying applications and classifying network traffic flows according to their source applications are critical for a broad range of network activities. Such a decision can be based on packet header fields, packet payload content, statistical characteristics of traffic and communication patterns of network hosts. However, most present techniques rely on some sort of apriori knowledge, which means they require labor-intensive preprocessing before running and cannot deal with previously unknown applications. In this paper, we propose a traffic classification system based on application signatures, with a novel approach to fully automate the process of deriving signatures from unidentified traffic. The key idea is to integrate statistics-based flow clustering with payload-based signature matching method, so as to eliminate the requirement of pre-labeled training data sets. We evaluate the efficiency of our approach using real-world traffic trace, and the results indicate that signature classifiers built from clustered data and pre-labeled data are able to achieve similar high accuracy better than 99%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The removal of lower molecular weight organic compounds (LMWOC) from water is of increasing concern. While, nano-fi ltration (NF) is a good option, it removes only a fraction of the LMWOC. In this paper, NF experiments were conducted to remove oxalic acid and diuron in combination with coagulation using poly-aluminum chloride (PAC) as the coagulant. The results showed that this hybrid treatment system was effective in removing oxalic acid where almost a 100% removal effi ciency of oxalic acid was achieved. However, using PAC as coagulant to remove diuron from water was not effective. In order to improve the removal efficiency of diuron, 0.02 M NaCl was added to diuron and a 40% increase in the removal of diuron was achieved. Higher removal of diuron was achieved when the solution was treated with reverse osmosis (RO) when compared to the nano-filtration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Four sizes (0.095, 0.53, 1.0 and 2.01 μm) of polystyrene latex particles were used to prepare monodispersed suspensions at three different ionic strengths (10−3, 10−2.5 and 10−2M KCl). Filtration experiments were conducted using those suspensions in a filter column with glass beads as porous medium. The filter bed depth and the filtration velocity were kept at 5 cm and 1 m/h, respectively. When suspensions with equal mass concentrations (0.2 mg/L) or equal surface area concentrations (0.12 cm2/mL) were filtered through the system, the largest particles exhibited higher initial single collector efficiency, η. The difference between the η of largest particles and the smaller particles was prominent for suspensions with equal surface area concentrations at higher ionic strengths. The collision efficiency, α of those particles exhibits higher values at higher ionic strengths. Both at equal mass concentration and equal surface area concentration, α is only slightly dependent on particle sizes when compared to its dependence on ionic strength. Further, it was found that the specific surface coverage was similar for 0.095 μm, 0.53 μm and 1.0 μm particles during the transient stage of filtration at any ionic strength when the surface area concentrations of those suspension were equal.