Power demand and energy usage of container crane - comparison between AC and DC drives


Autoria(s): Tran, Thanh; Nahavandi, Saeid; Reid, Robert
Contribuinte(s)

I,

Data(s)

01/01/2008

Resumo

The electrical data of two quay cranes, one has a DC drive system and the other has an AC drive system, in actual working conditions at a container terminal are measured and presented in this paper. Peak demand, energy usage, power factor and power quality are examined and compared.<br />

Identificador

http://hdl.handle.net/10536/DRO/DU:30018215

Idioma(s)

eng

Publicador

IEEE

Relação

http://dro.deakin.edu.au/eserv/DU:30018215/nahavandi-powerdemand-2008.pdf

http://dx.doi.org/10.1109/UPEC.2008.4651655

Direitos

2008, IEEE

Tipo