50 resultados para Mild Head

em CentAUR: Central Archive University of Reading - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here a method for calibrating an optical see-through Head Mounted Display (HMD) using techniques usually applied to camera calibration (photogrammetry). Using a camera placed inside the HMD to take pictures simultaneously of a tracked object and features in the HMD display, we could exploit established camera calibration techniques to recover both the intrinsic and extrinsic properties of the~HMD (width, height, focal length, optic centre and principal ray of the display). Our method gives low re-projection errors and, unlike existing methods, involves no time-consuming and error-prone human measurements, nor any prior estimates about the HMD geometry.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An eddy current testing system consists of a multi-sensor probe, a computer and a special expansion card and software for data-collection and analysis. The probe incorporates an excitation coil, and sensor coils; at least one sensor coil is a lateral current-normal coil and at least one is a current perturbation coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An eddy current testing system consists of a multi-sensor probe, computer and a special expansion card and software for data collection and analysis. The probe incorporates an excitation coil, and sensor coils; at least one sensor coil is a lateral current-normal coil and at least one is a current perturbation coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We measured the movements of soccer players heading a football in a fully immersive virtual reality environment. In mid-flight the ball’s trajectory was altered from its normal quasi-parabolic path to a linear one, producing a jump in the rate of change of the angle of elevation of gaze (α) from player to ball. One reaction time later the players adjusted their speed so that the rate of change of α increased when it had been reduced and reduced it when it had been increased. Since the result of the player’s movement was to regain a value of the rate of change close to that before the disturbance, the data suggest that the players have an expectation of, and memory for, the pattern that the rate of change of α will follow during the flight. The results support the general claim that players intercepting balls use servo control strategies and are consistent with the particular claim of Optic Acceleration Cancellation theory that the servo strategy is to allow α to increase at a steadily decreasing rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective was to evaluate the efficacy and tolerability of donepezil (5 and 10 mg/day) compared with placebo in alleviating manifestations of mild to moderate Alzheimer's disease (AD). Method: A systematic review of individual patient data from Phase II and III double-blind, randomised, placebo-controlled studies of up to 24 weeks and completed by 20 December 1999. The main outcome measures were the ADAS-cog, the CIBIC-plus, and reports of adverse events. Results: A total of 2376 patients from ten trials were randomised to either donepezil 5 mg/day (n = 821), 10 mg/day (n = 662) or placebo (n = 893). Cognitive performance was better in patients receiving donepezil than in patients receiving placebo. At 12 weeks the differences in ADAS-cog scores were 5 mg/day-placebo: - 2.1 [95% confidence interval (CI), - 2.6 to - 1.6; p < 0.001], 10 mg/day-placebo: - 2.5 ( - 3.1 to - 2.0; p < 0.001). The corresponding results at 24 weeks were - 2.0 ( - 2.7 to - 1.3; p < 0.001) and - 3.1 ( - 3.9 to - 2.4; p < 0.001). The difference between the 5 and 10 mg/day doses was significant at 24 weeks (p = 0.005). The odds ratios (OR) of improvement on the CIBIC-plus at 12 weeks were: 5 mg/day-placebo 1.8 (1.5 to 2.1; p < 0.001), 10 mg/day-placebo 1.9 (1.5 to 2.4; p < 0.001). The corresponding values at 24 weeks were 1.9 (1.5 to 2.4; p = 0.001) and 2.1 (1.6 to 2.8; p < 0.001). Donepezil was well tolerated; adverse events were cholinergic in nature and generally of mild severity and brief in duration. Conclusion: Donepezil (5 and 10 mg/day) provides meaningful benefits in alleviating deficits in cognitive and clinician-rated global function in AD patients relative to placebo. Increased improvements in cognition were indicated for the higher dose. Copyright © 2004 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first mycetome was discovered more than 340 yr ago in the human louse. Despite the remarkable biology and medical and social importance of human lice, its primary endosymbiont has eluded identification and characterization. Here, we report the host-symbiont interaction of the mycetomic bacterium of the head louse Pediculus humanus capitis and the body louse P. h. humanus. The endosymbiont represents a new bacterial lineage in the -Proteobacteria. Its closest sequenced relative is Arsenophonus nasoniae, from which it differs by more than 10%. A. nasoniae is a male-killing endosymbiont of jewel wasps. Using microdissection and multiphoton confocal microscopy, we show the remarkable interaction of this bacterium with its host. This endosymbiont is unique because it occupies sequentially four different mycetomes during the development of its host, undergoes three cycles of proliferation, changes in length from 2–4 µm to more than 100 µm, and has two extracellular migrations, during one of which the endosymbionts have to outrun its host’s immune cells. The host and its symbiont have evolved one of the most complex interactions: two provisional or transitory mycetomes, a main mycetome and a paired filial mycetome. Despite the close relatedness of body and head lice, differences are present in the mycetomic provisioning and the immunological response.—Perotti, M. A., Allen, J. M., Reed, D. L., Braig, H. R. Host-symbiont interactions of the primary endosymbiont of human head and body lice.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research demonstrates that dementia of the Alzheimer type (DAT) is characterised by deficits of episodic memory, especially in the acquisition of new material. As well as this deficit in acquisition, some researchers have also argued for a deficit in consolidation in DAT. We examined acquisition and consolidation by measuring the intertrial gained and lost access in DAT, Mild Cognitive Impairment (MCI) and controls. We report findings from a study of clinical data based on assessment of patients using three free recall trials of a word list. We found that both DAT and MCI groups showed a deficit in acquisition and consolidation of items between trials relative to controls. Moreover, the DAT group was significantly impaired relative to the MCI group for both acquisition and consolidation. Correlations within each group showed that there were strong relationships between intertrial measures and standard measures of memory function. Importantly in no group was there a significant correlation between our measures of acquisition and consolidation: we argue that these measures reflect different underlying processes, and the failure to consolidate in DAT and MCI is not related to the deficit in acquisition. Finally, we showed strong correlations between our measure and dementia severity, suggesting that acquisition and consolidation both get worse as the dementia progresses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone. The methods are also limited to optical see-through HMDs. Building on our existing HMD calibration method [1], we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside an HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in various positions. The locations of image features on the calibration object are then re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the display’s intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner in both see-through and in non-see-through modes and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors and involves no error-prone human measurements.

Relevância:

20.00% 20.00%

Publicador: