7 resultados para multiple-locus variable-number tandem repeat analysis
em Cochin University of Science
Resumo:
This study is about the analysis of some queueing models related to N-policy.The optimal value the queue size has to attain in order to turn on a single server, assuming that the policy is to turn on a single server when the queue size reaches a certain number, N, and turn him off when the system is empty.The operating policy is the usual N-policy, but with random N and in model 2, a system similar to the one described here.This study analyses “ Tandem queue with two servers”.Here assume that the first server is a specialized one.In a queueing system,under N-policy ,the server will be on vacation until N units accumulate for the first time after becoming idle.A modified version of the N-policy for an M│M│1 queueing system is considered here.The novel feature of this model is that a busy service unit prevents the access of new customers to servers further down the line.It is deals with a queueing model consisting of two servers connected in series with a finite intermediate waiting room of capacity k.Here assume that server I is a specialized server.For this model ,the steady state probability vector and the stability condition are obtained using matrix – geometric method.
Resumo:
There are a number of genes involved in the regulation of functional process in marine bivalves. In the case of pearl oyster, some of these genes have major role in the immune/defence function and biomineralization process involved in the pearl formation in them. As secondary filter feeders, pearl oysters are exposed to various kinds of stressors like bacteria, viruses, pesticides, industrial wastes, toxic metals and petroleum derivatives, making susceptible to diseases. Environmental changes and ambient stress also affect non-specific immunity, making the organisms vulnerable to infections. These stressors can trigger various cellular responses in the animals in their efforts to counteract the ill effects of the stress on them. These include the expression of defence related genes which encode factors such as antioxidant genes, pattern recognition receptor proteins etc. One of the strategies to combat these problems is to get insight into the disease resistance genes, and use them for disease control and health management. Similarly, although it is known that formation of pearl in molluscs is mediated by specialized proteins which are in turn regulated by specific genes encoding them, there is a paucity of sufficient information on these genes.In view of the above facts, studies on the defence related and pearl forming genes of the pearl oyster assumes importance from the point of view of both sustainable fishery management and aquaculture. At present, there is total lack of sufficient knowledge on the functional genes and their expressions in the Indian pearl oyster Pinctada fucata. Hence this work was taken up to identify and characterize the defence related and pearl forming genes, and study their expression through molecular means, in the Indian pearl oyster Pinctada fucata which are economically important for aquaculture at the southeast coast of India. The present study has successfully carried out the molecular identification, characterization and expression analysis of defence related antioxidant enzyme genes and pattern recognition proteins genes which play vital role in the defence against biotic and abiotic stressors. Antioxidant enzyme genes viz., Cu/Zn superoxide dismutase (Cu/Zn SOD), glutathione peroxidise (GPX) and glutathione-S-transferase (GST) were studied. Concerted approaches using the various molecular tools like polymerase chain reaction (PCR), random amplification of cDNA ends (RACE), molecular cloning and sequencing have resulted in the identification and characterization of full length sequences (924 bp) of the Cu/Zn SOD, most important antioxidant enzyme gene. BLAST search in NCBI confirmed the identity of the gene as Cu/Zn SOD. The presence of the characteristic amino acid sequences such as copper/zinc binding residues, family signature sequences and signal peptides were found out. Multiple sequence alignment comparison and phylogenetic analysis of the nucleotide and amino acid sequences using bioinformatics tools like BioEdit,MEGA etc revealed that the sequences were found to contain regions of diversity as well as homogeneity. Close evolutionary relationship between P. fucata and other aquatic invertebrates was revealed from the phylogenetic tree constructed using SOD amino acid sequence of P. fucata and other invertebrates as well as vertebrates
Resumo:
This work identifies the importance of plenum pressure on the performance of the data centre. The present methodology followed in the industry considers the pressure drop across the tile as a dependant variable, but it is shown in this work that this is the only one independent variable that is responsible for the entire flow dynamics in the data centre, and any design or assessment procedure must consider the pressure difference across the tile as the primary independent variable. This concept is further explained by the studies on the effect of dampers on the flow characteristics. The dampers have found to introduce an additional pressure drop there by reducing the effective pressure drop across the tile. The effect of damper is to change the flow both in quantitative and qualitative aspects. But the effect of damper on the flow in the quantitative aspect is only considered while using the damper as an aid for capacity control. Results from the present study suggest that the use of dampers must be avoided in data centre and well designed tiles which give required flow rates must be used in the appropriate locations. In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results.
Resumo:
Warships are generally sleek, slender with V shaped sections and block coefficient below 0.5, compared to fuller forms and higher values for commercial ships. They normally operate in the higher Froude number regime, and the hydrodynamic design is primarily aimed at achieving higher speeds with the minimum power. Therefore the structural design and analysis methods are different from those for commercial ships. Certain design guidelines have been given in documents like Naval Engineering Standards and one of the new developments in this regard is the introduction of classification society rules for the design of warships.The marine environment imposes subjective and objective uncertainties on ship structure. The uncertainties in loads, material properties etc.,. make reliable predictions of ship structural response a difficult task. Strength, stiffness and durability criteria for warship structures can be established by investigations on elastic analysis, ultimate strength analysis and reliability analysis. For analysis of complicated warship structures, special means and valid approximations are required.Preliminary structural design of a frigate size ship has been carried out . A finite element model of the hold model, representative of the complexities in the geometric configuration has been created using the finite element software NISA. Two other models representing the geometry to a limited extent also have been created —- one with two transverse frames and the attached plating alongwith the longitudinal members and the other representing the plating and longitudinal stiffeners between two transverse frames. Linear static analysis of the three models have been carried out and each one with three different boundary conditions. The structural responses have been checked for deflections and stresses against the permissible values. The structure has been found adequate in all the cases. The stresses and deflections predicted by the frame model are comparable with those of the hold model. But no such comparison has been realized for the interstiffener plating model with the other two models.Progressive collapse analyses of the models have been conducted for the three boundary conditions, considering geometric nonlinearity and then combined geometric and material nonlinearity for the hold and the frame models. von Mises — lllyushin yield criteria with elastic-perfectly plastic stress-strain curve has been chosen. ln each case, P-Delta curves have been generated and the ultimate load causing failure (ultimate load factor) has been identified as a multiple of the design load specified by NES.Reliability analysis of the hull module under combined geometric and material nonlinearities have been conducted. The Young's Modulus and the shell thickness have been chosen as the variables. Randomly generated values have been used in the analysis. First Order Second Moment has been used to predict the reliability index and thereafter, the probability of failure. The values have been compared against standard values published in literature.
Resumo:
Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.
Resumo:
This thesis Entitled “modelling and analysis of recurrent event data with multiple causes.Survival data is a term used for describing data that measures the time to occurrence of an event.In survival studies, the time to occurrence of an event is generally referred to as lifetime.Recurrent event data are commonly encountered in longitudinal studies when individuals are followed to observe the repeated occurrences of certain events. In many practical situations, individuals under study are exposed to the failure due to more than one causes and the eventual failure can be attributed to exactly one of these causes.The proposed model was useful in real life situations to study the effect of covariates on recurrences of certain events due to different causes.In Chapter 3, an additive hazards model for gap time distributions of recurrent event data with multiple causes was introduced. The parameter estimation and asymptotic properties were discussed .In Chapter 4, a shared frailty model for the analysis of bivariate competing risks data was presented and the estimation procedures for shared gamma frailty model, without covariates and with covariates, using EM algorithm were discussed. In Chapter 6, two nonparametric estimators for bivariate survivor function of paired recurrent event data were developed. The asymptotic properties of the estimators were studied. The proposed estimators were applied to a real life data set. Simulation studies were carried out to find the efficiency of the proposed estimators.
Resumo:
In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results