6 resultados para Deliberate fire, repetition, crime analysis, intelligence led-policing, forensic intelligence

em Cochin University of Science


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The hazards associated with major accident hazard (MAH) industries are fire, explosion and toxic gas releases. Of these, toxic gas release is the worst as it has the potential to cause extensive fatalities. Qualitative and quantitative hazard analyses are essential for the identitication and quantification of the hazards associated with chemical industries. This research work presents the results of a consequence analysis carried out to assess the damage potential of the hazardous material storages in an industrial area of central Kerala, India. A survey carried out in the major accident hazard (MAH) units in the industrial belt revealed that the major hazardous chemicals stored by the various industrial units are ammonia, chlorine, benzene, naphtha, cyclohexane, cyclohexanone and LPG. The damage potential of the above chemicals is assessed using consequence modelling. Modelling of pool fires for naphtha, cyclohexane, cyclohexanone, benzene and ammonia are carried out using TNO model. Vapor cloud explosion (VCE) modelling of LPG, cyclohexane and benzene are carried out using TNT equivalent model. Boiling liquid expanding vapor explosion (BLEVE) modelling of LPG is also carried out. Dispersion modelling of toxic chemicals like chlorine, ammonia and benzene is carried out using the ALOHA air quality model. Threat zones for different hazardous storages are estimated based on the consequence modelling. The distance covered by the threat zone was found to be maximum for chlorine release from a chlor-alkali industry located in the area. The results of consequence modelling are useful for the estimation of individual risk and societal risk in the above industrial area.Vulnerability assessment is carried out using probit functions for toxic, thermal and pressure loads. Individual and societal risks are also estimated at different locations. Mapping of threat zones due to different incident outcome cases from different MAH industries is done with the help of Are GIS.Fault Tree Analysis (FTA) is an established technique for hazard evaluation. This technique has the advantage of being both qualitative and quantitative, if the probabilities and frequencies of the basic events are known. However it is often difficult to estimate precisely the failure probability of the components due to insufficient data or vague characteristics of the basic event. It has been reported that availability of the failure probability data pertaining to local conditions is surprisingly limited in India. This thesis outlines the generation of failure probability values of the basic events that lead to the release of chlorine from the storage and filling facility of a major chlor-alkali industry located in the area using expert elicitation and proven fuzzy logic. Sensitivity analysis has been done to evaluate the percentage contribution of each basic event that could lead to chlorine release. Two dimensional fuzzy fault tree analysis (TDFFTA) has been proposed for balancing the hesitation factor invo1ved in expert elicitation .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Occupational stress is becoming a major issue in both corporate and social agenda .In industrialized countries, there have been quite dramatic changes in the conditions at work, during the last decade ,caused by economic, social and technical development. As a consequence, the people today at work are exposed to high quantitative and qualitative demands as well as hard competition caused by global economy. A recent report says that ailments due to work related stress is likely to cost India’s exchequer around 72000 crores between 2009 and 2015. Though India is a fast developing country, it is yet to create facilities to mitigate the adverse effects of work stress, more over only little efforts have been made to assess the work related stress.In the absence of well defined standards to assess the work related stress in India, an attempt is made in this direction to develop the factors for the evaluation of work stress. Accordingly, with the help of existing literature and in consultation with the safety experts, seven factors for the evaluation of work stress is developed. An instrument ( Questionnaire) was developed using these seven factors for the evaluation of work stress .The validity , and unidimensionality of the questionnaire was ensured by confirmatory factor analysis. The reliability of the questionnaire was ensured before administration. While analyzing the relation ship between the variables, it is noted that no relationship exists between them, and hence the above factors are treated as independent factors/ variables for the purpose of research .Initially five profit making manufacturing industries, under public sector in the state of Kerala, were selected for the study. The influence of factors responsible for work stress is analyzed in these industries. These industries were classified in to two types, namely chemical and heavy engineering ,based on the product manufactured and work environment and the analysis is further carried out for these two categories.The variation of work stress with different age , designation and experience of the employees are analyzed by means of one-way ANOVA. Further three different type of modelling of work stress, namely factor modelling, structural equation modelling and multinomial logistic regression modelling was done to analyze the association of factors responsible for work stress. All these models are found equally good in predicting the work stress.The present study indicates that work stress exists among the employees in public sector industries in Kerala. Employees belonging to age group 40-45yrs and experience groups 15-20yrs had relatively higher work demand ,low job control, and low support at work. Low job control was noted among lower designation levels, particularly at the worker level in these industries. Hence the instrument developed using the seven factors namely demand, control, manager support, peer support, relationship, role and change can be effectively used for the evaluation of work stress in industries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work identifies the importance of plenum pressure on the performance of the data centre. The present methodology followed in the industry considers the pressure drop across the tile as a dependant variable, but it is shown in this work that this is the only one independent variable that is responsible for the entire flow dynamics in the data centre, and any design or assessment procedure must consider the pressure difference across the tile as the primary independent variable. This concept is further explained by the studies on the effect of dampers on the flow characteristics. The dampers have found to introduce an additional pressure drop there by reducing the effective pressure drop across the tile. The effect of damper is to change the flow both in quantitative and qualitative aspects. But the effect of damper on the flow in the quantitative aspect is only considered while using the damper as an aid for capacity control. Results from the present study suggest that the use of dampers must be avoided in data centre and well designed tiles which give required flow rates must be used in the appropriate locations. In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recent boom in wireless communication industry, especially in the area of cellular telephony and wireless data communication, has led to the increased demand for multi band antennas. In such applications the issues to be addressed are, wide bandwidth and gain, while striving for miniature geometry. A dual frequency configuration useful in GSM1800 and Blue tooth, is one that operates with similar properties, both in terms of reflection and radiation characteristics, in the two bands of interest. Dual frequency operations can be realized by exciting the Microstrip Patch Antenna (MPA) using a single feed [1] or dual feed [2]. In this paper, Conformal FDTD[3] method with Perfect Magnetic Conductor (PMC) applied along the plane of symmetry [4] is used to study the characteristics of an Octagonal MPA. The theoretical results are compared against the experimental and IE3D™ simulated results