9 resultados para relative static method
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The aim of this work was to calibrate the material properties including strength and strain values for different material zones of ultra-high strength steel (UHSS) welded joints under monotonic static loading. The UHSS is heat sensitive and softens by heat due to welding, the affected zone is heat affected zone (HAZ). In this regard, cylindrical specimens were cut out from welded joints of Strenx® 960 MC and Strenx® Tube 960 MH, were examined by tensile test. The hardness values of specimens’ cross section were measured. Using correlations between hardness and strength, initial material properties were obtained. The same size specimen with different zones of material same as real specimen were created and defined in finite element method (FEM) software with commercial brand Abaqus 6.14-1. The loading and boundary conditions were defined considering tensile test values. Using initial material properties made of hardness-strength correlations (true stress-strain values) as Abaqus main input, FEM is utilized to simulate the tensile test process. By comparing FEM Abaqus results with measured results of tensile test, initial material properties will be revised and reused as software input to be fully calibrated in such a way that FEM results and tensile test results deviate minimum. Two type of different S960 were used including 960 MC plates, and structural hollow section 960 MH X-joint. The joint is welded by BöhlerTM X96 filler material. In welded joints, typically the following zones appear: Weld (WEL), Heat affected zone (HAZ) coarse grained (HCG) and fine grained (HFG), annealed zone, and base material (BaM). Results showed that: The HAZ zone is softened due to heat input while welding. For all the specimens, the softened zone’s strength is decreased and makes it a weakest zone where fracture happens while loading. Stress concentration of a notched specimen can represent the properties of notched zone. The load-displacement diagram from FEM modeling matches with the experiments by the calibrated material properties by compromising two correlations of hardness and strength.
Resumo:
Talouden kasvaessa myös tavarankuljetusmäärät kasvavat. Kuljetusjärjestelmät ja niiden sujuva toiminta on erittäin tärkeää taloudellisen kasvun kannalta tällä hetkellä, ja se tulee olemaan yhä tärkeämpää tulevaisuudessa. Tulevaisuudessa tarvitaan kokonaisvaltainen ja selkeästi tehokkaampi kuljetusjärjestelmä, mikäli tulevaisuuden kuljetusvirrat halutaan hoitaa kestävästi. Tässä opinnäytetyössäni tutkin kolmen eurooppalaisen kuljetusjärjestelmän (rautatiet, lentoliikenne ja konttiliikenne meritse) suhteellista teknistä tehokkuutta ja menetelmänä on data envelopment analysis (DEA). Vertailtaessa kuljetusjärjestelmiä löytyi suuria eroja kuljetusmuotojen välille. lentoyhtiöt suoriutuivat huomattavan tasaisesti eli tehokkaiden ja ei-tehokkaiden toimijoiden välillä ei ollut suuria eroja. Rautatiepuolella erot venyivät huomattavan suuriksi niin eri yritysten välillä kuin jopa saman yrityksen sisällä eri vuosina. Pikaisemmassa laivayhtiöiden tarkastelussa erot niiden välillä olivat lähes yhtä pieniä kuin lentoyhtiöiden välillä. Tarkasteltaessa omistajuuden vaikutusta lentoyhtiöiden toiminnassa huomattiin, että yksityisessä omistuksessa olevat yritykset olivat huomattavasti tehokkaampia matkustajien kuljettamisessa. Rahtipuolella merkittäviä eroja ei havaittu. Merkittävät korrelaatiot eri mallien välillä antoivat joitain viitteitä myös kuljetuspoliittiseen päätöksentekoon; investoinnit matkustajienkuljetuksiin raiteilla parantaisivat koko rautatiepuolen teokkuutta, mutta myös samalla lentopuolen matkustajakuljetuksen tehokkuutta.
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
Työn tutkimusongelma oli selventää, tutkia ja analysoida dynaamisen hinnoittelun tekijät ja mahdollisuudet tuotevarianttien hinnoittelussa. Tutkimusongelman selvittämiseksi työlle asetettiin 8 tavoitetta - Saada selville miksi tuotevarianttien hinnoittelu on ongelmallista - Esittää kuinka tuotevarianttien hinnat teoreettisesti tulisi asettaa - Tunnistaa tuotevarianttien hinnoittelun ulottuvuudet ja selvittää dynaamisen hinnoittelun edut staattiseen hinnoitteluun verrattuna - Esitellä analyysikehikko hinnoittelun tilan analysointiin - Tunnistaa dynaamisen hinnoittelun tuotevarianteille suomat mahdollisuudet - Etsiä soveltuvat hinnoittelumenetelmät tuotevarianttien dynaamiseen hinnoitteluun - Analysoida tuotevariantteja myyvän yrityksen hinnoittelu - Tunnistaa ja arvioida dynaamisen hinnoittelun edut yritykselle Diplomityössä käytettiin useita tutkimusmenetelmiä. Perustieto haettiin kirjallisuustutkimuksella ja sitä täydennettiin haastatteluilla. Tutkimusprosessi alkoi tutkimuksella tuotevarianttien hinnoittelusta ja kirjallisuuden perusteella luotiin näkökulma ja yleiset kehityssuunnat tarkempaa tutkimusta varten. Kaksi tärkeintä tuotevariaatioiden hinnoitteludimensiota tunnistettiin ja niiden analysointia varten luotiin nelikenttämalli. Kirjallisuustutkimuksen ja tarkemman kohdeyrityksen tarkastelun perusteella dynaaminen tuotelinjahinnoittelu on tuotevarianttien dynaamisen hinnoittelun tavoitetila. Nelikenttämallia käytettiin kohdeyrityksen hinnoittelun tilan arviointiin ja dynaamisen hinnoittelun suurimmat hyödyt löydettiin. Tutkimuksen päätulokset ovat - Hinnoittelun dynaamisuutta tulee tuotevarianteilla tutkia hinnoittelun älykkyyden ja kehittyneisyyden kanssa - Tuotevariaatioiden hinnoittelun tavoitetila on dynaaminen tuotelinjahinnoittelu - Hinnoittelun kehittäminen staattisesta dynaamiseen tuo huomattavia etuja - Tärkein etu on parempi hintojen hallinta ja mahdollisuus johtaa hintoja tehokkaasti. Tämän vuoksi hinnoitteluanalyysissa havaittiin selvästi lisääntyneitä voittoja - Hinnoittelun älykkyyden nostaminen hyödyttää yritystä ja saa aikaan lisäyksen voitoissa
Resumo:
Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.
Resumo:
The aim of this study was to describe the demographic, clinicopathological, biological and morphometric features of Libyan breast cancer patients. The supporting value of nuclear morphometry and static image cytometry in the sensitivity for detecting breast cancer in conventional fine-needle aspiration biopsies were estimated. The findings were compared with findings in breast cancer in Finland and Nigeria. In addation, the value of ER and PR were evaluated. There were 131 histological samples, 41 cytological samples, and demographic and clinicopathological data from 234 Libyan patients. The Libyan breast cancer is dominantly premenopausal and in this feature it is similar to breast cancer in sub-Saharan Africans, but clearly different from breast cancer in Europeans, whose cancers are dominantly postmenopausal in character. At presention most Libyan patients have locally advanced disease, which is associated with poor survival rates. Nuclear morphometry and image DNA cytometry agree with earlier published data in the Finnish population and indicate that nuclear size and DNA analysis of nuclear content can be used to increase the cytological sensitivity and specificity in doubtful breast lesions, particularly when free cell sampling method is used. Combination of the morphometric data with earlier free cell data gave the following diagnostic guidelines: Range of overlap in free cell samples: 55 μm2 -71 μm2. Cut-off values for diagnostic purposes: Mean nuclear area (MNA) >54 μm2 for 100% detection of malignant cases (specificity 84 %), MNA < 72 μm2 for 100% detection of benign cases (sensitivity 91%). Histomorphometry showed a significant correlation between the MNA and most clinicopathological features, with the strongest association observed for histological grade (p <0.0001). MNA seems to be a prognosticator in Libyan breast cancer (Pearson’s test r = - 0.29, p = 0.019), but at lower level of significance than in the European material. A corresponding relationship was not found in shape-related morphometric features. ER and PR staining scores were in correlation with the clinical stage (p= 0.017, and 0.015, respectively), and also associated with lymph node negative patients (p=0.03, p=0.05, respectively). Receptor-positive (HR+) patients had a better survival. The fraction of HR+ cases among Libyan breast cancers is about the same as the fraction of positive cases in European breast cancer. The study suggests that also weak staining (corresponding to as few as 1% positive cells) has prognostic value. The prognostic significance may be associated with the practice to use antihormonal therapy in HR+ cases. The low survival and advanced presentation is associated with active cell proliferation, atypical nuclear morphology and aneuploid nuclear DNA content in Libyan breast cancer patients. The findings support the idea that breast cancer is not one type of disease, but should probably be classified into premenopausal and post menopausal types.
Resumo:
The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T-10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 1720 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 5080 KIAS (90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.
Resumo:
The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T- 10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 17−20 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 50−80 KIAS (∼90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.
Resumo:
Thermal cutting methods, are commonly used in the manufacture of metal parts. Thermal cutting processes separate materials by using heat. The process can be done with or without a stream of cutting oxygen. Common processes are Oxygen, plasma and laser cutting. It depends on the application and material which cutting method is used. Numerically-controlled thermal cutting is a cost-effective way of prefabricating components. One design aim is to minimize the number of work steps in order to increase competitiveness. This has resulted in the holes and openings in plate parts manufactured today being made using thermal cutting methods. This is a problem from the fatigue life perspective because there is local detail in the as-welded state that causes a rise in stress in a local area of the plate. In a case where the static utilization of a net section is full used, the calculated linear local stresses and stress ranges are often over 2 times the material yield strength. The shakedown criteria are exceeded. Fatigue life assessment of flame-cut details is commonly based on the nominal stress method. For welded details, design standards and instructions provide more accurate and flexible methods, e.g. a hot-spot method, but these methods are not universally applied to flame cut edges. Some of the fatigue tests of flame cut edges in the laboratory indicated that fatigue life estimations based on the standard nominal stress method can give quite a conservative fatigue life estimate in cases where a high notch factor was present. This is an undesirable phenomenon and it limits the potential for minimizing structure size and total costs. A new calculation method is introduced to improve the accuracy of the theoretical fatigue life prediction method of a flame cut edge with a high stress concentration factor. Simple equations were derived by using laboratory fatigue test results, which are published in this work. The proposed method is called the modified FAT method (FATmod). The method takes into account the residual stress state, surface quality, material strength class and true stress ratio in the critical place.