16 resultados para passive intermodulation

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the times preceding the Second World War the subject of aircraft tracking has been a core interest to both military and non-military aviation. During subsequent years both technology and configuration of the radars allowed the users to deploy it in numerous fields, such as over-the-horizon radar, ballistic missile early warning systems or forward scatter fences. The latter one was arranged in a bistatic configuration. The bistatic radar has continuously re-emerged over the last eighty years for its intriguing capabilities and challenging configuration and formulation. The bistatic radar arrangement is used as the basis of all the analyzes presented in this work. The aircraft tracking method of VHF Doppler-only information, developed in the first part of this study, is solely based on Doppler frequency readings in relation to time instances of their appearance. The corresponding inverse problem is solved by utilising a multistatic radar scenario with two receivers and one transmitter and using their frequency readings as a base for aircraft trajectory estimation. The quality of the resulting trajectory is then compared with ground-truth information based on ADS-B data. The second part of the study deals with the developement of a method for instantaneous Doppler curve extraction from within a VHF time-frequency representation of the transmitted signal, with a three receivers and one transmitter configuration, based on a priori knowledge of the probability density function of the first order derivative of the Doppler shift, and on a system of blocks for identifying, classifying and predicting the Doppler signal. The extraction capabilities of this set-up are tested with a recorded TV signal and simulated synthetic spectrograms. Further analyzes are devoted to more comprehensive testing of the capabilities of the extraction method. Besides testing the method, the classification of aircraft is performed on the extracted Bistatic Radar Cross Section profiles and the correlation between them for different types of aircraft. In order to properly estimate the profiles, the ADS-B aircraft location information is adjusted based on extracted Doppler frequency and then used for Bistatic Radar Cross Section estimation. The classification is based on seven types of aircraft grouped by their size into three classes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exchange traded fund (ETF) is a financial instrument that tracks some predetermined index. Since their initial establishment in 1993, ETFs have grown in importance in the field of passive investing. The main reason for the growth of the ETF industry is that ETFs combine benefits of stock investing and mutual fund investing. Although ETFs resemble mutual funds in many ways, also many differences occur. In addition, ETFs not only differ from mutual funds but also differ among each other. ETFs can be divided into two categories, i.e. market capitalisation ETFs and fundamental (or strategic) ETFs, and further into subcategories depending on their fundament basis. ETFs are a useful tool for diversification especially for a long-term investor. Although the economic importance of ETFs has risen drastically during the past 25 years, the differences and risk-return characteristics of fundamental ETFs have yet been rather unstudied area. In effect, no previous research on market capitalisation and fundamental ETFs was found during the research process. For its part, this thesis seeks to fill this research gap. The studied data consist of 50 market capitalisation ETFs and 50 fundamental ETFs. The fundaments, on which the indices that the fundamental ETFs track, were not limited nor segregated into subsections. The two types of ETFs were studied at an aggregate level as two different research groups. The dataset ranges from June 2006 to December 2014 with 103 monthly observations. The data was gathered using Bloomberg Terminal. The analysis was conducted as an econometric performance analysis. In addition to other econometric measures, the methods that were used in the performance analysis included modified Value-at-Risk, modified Sharpe ratio and Treynor ratio. The results supported the hypothesis that passive market capitalisation ETFs outperform active fundamental ETFs in terms of risk-adjusted returns, though the difference is rather small. Nevertheless, when taking into account the higher overall trading costs of the fundamental ETFs, the underperformance gap widens. According to the research results, market capitalisation ETFs are a recommendable diversification instrument for a long-term investor. In addition to better risk-adjusted returns, passive ETFs are more transparent and the bases of their underlying indices are simpler than those of fundamental ETFs. ETFs are still a young financial innovation and hence data is scarcely available. On future research, it would be valuable to research the differences in risk-adjusted returns also between the subsections of fundamental ETFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this master’s thesis is to gain an understanding of passive safety systems’ role in modern nuclear reactors projects and to research the failure modes of passive decay heat removal safety systems which use phenomenon of natural circulation. Another purpose is to identify the main physical principles and phenomena which are used to establish passive safety tools in nuclear power plants. The work describes passive decay heat removal systems used in AES-2006 project and focuses on the behavior of SPOT PG system. The descriptions of the main large-scale research facilities of the passive safety systems of the AES-2006 power plant are also included. The work contains the calculations of the SPOT PG system, which was modeled with thermal-hydraulic system code TRACE. The dimensions of the calculation model are set according to the dimensions of the real SPOT PG system. In these calculations three parameters are investigated as a function of decay heat power: the pressure of the system, the natural circulation mass flow rate around the closed loop, and the level of liquid in the downcomer. The purpose of the calculations is to test the ability of the SPOT PG system to remove the decay heat from the primary side of the nuclear reactor in case of failure of one, two, or three loops out of four. The calculations show that three loops of the SPOT PG system have adequate capacity to provide the necessary level of safety. In conclusion, the work supports the view that passive systems could be widely spread in modern nuclear projects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The subject of this study is the use of direct cinema style in documentary film. The main purpose of this thesis was to the research the ways in which direct cinema style attempts to show and achieve truth in documentary films. The following questions were posed: Is it possible to depict reality in a documentary film; how does the choice of using this style affect the final documentary? The essential purpose of this study was to try to see whether the direct cinema style works when trying to achieve truth in a documentary film. This work consints of two elements, the theoretical part and the short documentary. The theoretical part deals with the history, the truth, and the direct cinema- style in documentaries. The theoretical information of direct cinema has been used when making the short documentary. In the documentary Tuloaula 2 I have studied the way in which using direct cinema -style works in practise. The documentary has followed as strictly as possible the direct cinema style. I was the director, the cameraman and the editor of my documentary film. In the documentary film Tuloaula 2 it appeared that the direct cinema style works best when filming everyday life. By using this style it is easy for the director to observe and leave his own persona in the background. The strength in using the direct cinema style is that it enables the viewer to build his/her own impression on the subject. Even though the direct cinema style aims to achieve objectivity the director has to make numerous subjective choices during both the filming and the editing process. These subjective choices automatically effect the "truth" of the documentary film. The difficulty in a direct cinema style is the large amount of material. This often leads to a long editing phase, which is not often possible in the busy production schedules. The direct cinema style is not at its best when shooting people who are passive because their attention often focuses too much on the camera. In general, the best way to make a documentary film would be to use many documentary styles in one film and not to srictly concentrate on only one style.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tutkimuksen tarkoituksena oli selvittää passiivisen mobilisaation vaikutusta ylemmän nilkkanivelen liikelaajuuteen ja siinä mahdollisesti esiintyvään kipuun. Lisäksi tavoitteena oli lisätä manuaalisen terapian tunnettuutta yhtenä jalkaterapian hoitomenetelmänä. Tutkimusmenetelmä oli kokeellinen yksittäistapaustutkimus. Tutkimuseen valittiin harkinnanvaraisesti neljä (n=4) henkilöä, joilla oli ainakin toisen ylemmän nilkkanivelen liikelaajuus dorsaalifleksioon alle 10̊. Lisäksi nivelessä saattoi esiintyä kipua. Passiivista mobilisaatiota annettiin kaksi kertaa viikossa kolmen viikon ajan. Perustasonmittaukset suoritettiin neljä kertaa ennen hoitojaksoa kahden viikon aikana ja kolme kertaa seurantajakson (6 viikkoa) aikana kahden viikon välein. Tiedonhankintamenetelminä olivat kysely- ja tutkimuslomake, kivun ja haitan arviointilomake. Ylemmän nilkkanivelen liikelaajuuden mittaus tehtiin Ficherin goniometrillä. Perustasonmittauksissa nilkkanivelten liikelaajuuden vaihtelu oli 3̊̊-14̊ polvi suorana ja polvi koukussa 5̊- 16̊. Kyselyn mukaan kahdella tutkittavalla esiintyi kipua ainakin toisessa ylemmässä nilkkanivelessä. Hoitojakson aikana kaikien tutkittavien liikelaajuus lisääntyi 3̊- 8̊ polvi suorana ja polvi koukussa 2̈̊- 9̊. Kolme henkilöä saavutetti normaalin kävelyn vaativan liikelaajuuden, 10̊ polvi suorana ja 15̊ polvi koukussa. Seurantavaiheessa liikelaajuudet lisääntyivät alkumittauksiin verratuna kolmella henkilöllä. Yhdellä henkilöllä saavutettu liikelaajuus säilyi seurantavaiheen loppuun asti. Mobilisaatio ei vaikuttanut merkittävästi ylemmän nilkkanivelen kipuun. Koska tämä oli yksittäistapaustutkimus ja tutkimusjoukko oli pieni (N=4), tutkimustuloksia ei voida yleistää. Tutkimustulokset ovat kuitenkin lupaavia ja ne antavat viitteen siitä, että passiivisella mobilisaatiolla voidaan lisätä ylemmän nilkkanivelen liikelaajuutta. Tutkimus antaa lisää näyttöä jalkaterapian alaraajoja tukevista hoitomenetelmistä ja erityisesti nivelen passiivisen mobilisaation vaikutuksesta ylemmän nilkkanivelen liikerajoitukseen. Mobilisaatio on tehokas hoitomenetelmä ja hyvä vaihtoehto perinteisille pehmytkudosperäisen jäykän nilkan hoitomuodoille. Tutkimusta ja sen tuloksia voivat hyödyntää kaikki terveysalan ammattilaiset, jotka työssään käyttävät passiivista mobilisaatiota. Tutkimuksen avulla jalkaterapeutit voivat parantaa omaa kriittistä työotettaan, työnsä seurantaa sekä hoitotulosten dokumentointia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The safe use of nuclear power plants (NPPs) requires a deep understanding of the functioning of physical processes and systems involved. Studies on thermal hydraulics have been carried out in various separate effects and integral test facilities at Lappeenranta University of Technology (LUT) either to ensure the functioning of safety systems of light water reactors (LWR) or to produce validation data for the computer codes used in safety analyses of NPPs. Several examples of safety studies on thermal hydraulics of the nuclear power plants are discussed. Studies are related to the physical phenomena existing in different processes in NPPs, such as rewetting of the fuel rods, emergency core cooling (ECC), natural circulation, small break loss-of-coolant accidents (SBLOCA), non-condensable gas release and transport, and passive safety systems. Studies on both VVER and advanced light water reactor (ALWR) systems are included. The set of cases include separate effects tests for understanding and modeling a single physical phenomenon, separate effects tests to study the behavior of a NPP component or a single system, and integral tests to study the behavior of the whole system. In the studies following steps can be found, not necessarily in the same study. Experimental studies as such have provided solutions to existing design problems. Experimental data have been created to validate a single model in a computer code. Validated models are used in various transient analyses of scaled facilities or NPPs. Integral test data are used to validate the computer codes as whole, to see how the implemented models work together in a code. In the final stage test results from the facilities are transferred to the NPP scale using computer codes. Some of the experiments have confirmed the expected behavior of the system or procedure to be studied; in some experiments there have been certain unexpected phenomena that have caused changes to the original design to avoid the recognized problems. This is the main motivation for experimental studies on thermal hydraulics of the NPP safety systems. Naturally the behavior of the new system designs have to be checked with experiments, but also the existing designs, if they are applied in the conditions that differ from what they were originally designed for. New procedures for existing reactors and new safety related systems have been developed for new nuclear power plant concepts. New experiments have been continuously needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Meluntorjuntaan on perinteisesti käytetty passiivisia menetelmiä. Monissa sovelluksissa melua voidaan vaimentaa myös aktiivisella meluntorjunnalla. Tässä työssä tutkitaan aktiivisen meluntorjunnan signaalinkäsittelyä sekä signaalinkäsittelyyn soveltuvia laitteistoja. Lisäksi selvitetään ANC-järjestelmien (Active Noise Control) toimintaanja signaalinkäsittelyyn vaikuttavia tekijöitä. Tutkinnassa rajoitutaan yksikanavaisiin järjestelmiin. Esimerkkisovelluksena käytetään ulkotilan melunvaimennukseen soveltuvaa järjestelmää. Esimerkkijärjestelmään suunniteltiin signaalinkäsittelylaitteisto, jonka soveltuvuutta järjestelmän signaalinkäsittelyyn selvitettiin suorituskykymittauksin ja kokeellisin mittauksin.Lisäksi pohditaan signaalinkäsittelyn toteuttamista tutkittavassa järjestelmässä ja sovelluskohteessa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ympäristömelu on nyky-yhteiskunnassa kasvava ongelma. Perinteisesti tätä melua on pyritty vähentämään passiivisen melunvaimennuksen avulla, kuten tienvarsien melumuureilla. Melua voidaan kuitenkin vaimentaa myös aktiivisellameluntorjunnalla (ANC, active noise control). Tässä työssä selvitetäänmitä ongelmia kohdataan, kun ANC-järjestelmää suunnitellaan ulkotiloihin ja mitä ominaisuuksia tällaiselta järjestelmältä vaaditaan. Työssä tutkitaan myös miten vaihtuvat ympäristöolosuhteet ja ulkoakustiset ilmiöt vaikuttavat ANC-järjestelmän toimintaan. Tutkimuksen pohjalta toteutetaan oma ANC-järjestelmä, jonka suorituskykyä työssä mitataan sekä komponentti- että järjestelmätasolla. Myös järjestelmän toimivuuteen vaikuttavia tekijöitä kartoitetaan mittausten avulla. Erikoistapauksena työssä selvitetään voiko suunnitellulla ANC-järjestelmällä vaimentaa impulssimaista melua paikallisesti.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ydinvoimalaitokset on suunniteltu ja rakennettu niin, että niillä on kyky selviytyä erilaisista käyttöhäiriöistä ja onnettomuuksista ilman laitoksen vahingoittumista sekä väestön ja ympäristön vaarantumista. On erittäin epätodennäköistä, että ydinvoimalaitosonnettomuus etenee reaktorisydämen vaurioitumiseen asti, minkä seurauksena sydänmateriaalien hapettuminen voi tuottaa vetyä. Jäädytyspiirin rikkoutumisen myötä vety saattaa kulkeutua ydinvoimalaitoksen suojarakennukseen, jossa se voi muodostaa palavan seoksen ilman hapen kanssa ja palaa tai jopa räjähtää. Vetypalosta aiheutuvat lämpötila- ja painekuormitukset vaarantavat suojarakennuksen eheyden ja suojarakennuksen sisällä olevien turvajärjestelmien toimivuuden, joten tehokas ja luotettava vedynhallintajärjestelmä on tarpeellinen. Passiivisia autokatalyyttisiä vetyrekombinaattoreita käytetäänyhä useammissa Euroopan ydinvoimaitoksissa vedynhallintaan. Nämä rekombinaattorit poistavat vetyä katalyyttisellä reaktiolla vedyn reagoidessa katalyytin pinnalla hapen kanssa muodostaen vesihöyryä. Rekombinaattorit ovat täysin passiivisiaeivätkä tarvitse ulkoista energiaa tai operaattoritoimintaa käynnistyäkseen taitoimiakseen. Rekombinaattoreiden käyttäytymisen tutkimisellatähdätään niiden toimivuuden selvittämiseen kaikissa mahdollisissa onnettomuustilanteissa, niiden suunnittelun optimoimiseen sekä niiden optimaalisen lukumäärän ja sijainnin määrittämiseen suojarakennuksessa. Suojarakennuksen mallintamiseen käytetään joko keskiarvoistavia ohjelmia (Lumped parameter (LP) code), moniulotteisia virtausmalliohjelmia (Computational Fluid Dynamics, CFD) tai näiden yhdistelmiä. Rekombinaattoreiden mallintaminen on toteutettu näissä ohjelmissa joko kokeellisella, teoreettisella tai yleisellä (eng. Global Approach) mallilla. Tämä diplomityö sisältää tulokset TONUS OD-ohjelman sisältämän Siemens FR90/1-150 rekombinaattorin mallin vedynkulutuksen tarkistuslaskuista ja TONUS OD-ohjelmalla suoritettujen laskujen tulokset Siemens rekombinaattoreiden vuorovaikutuksista. TONUS on CEA:n (Commissariat à 1'En¬ergie Atomique) kehittämä LP (OD) ja CFD -vetyanalyysiohjelma, jota käytetään vedyn jakautumisen, palamisenja detonaation mallintamiseen. TONUS:sta käytetään myös vedynpoiston mallintamiseen passiivisilla autokatalyyttisillä rekombinaattoreilla. Vedynkulutukseen vaikuttavat tekijät eroteltiin ja tutkittiin yksi kerrallaan. Rekombinaattoreiden vuorovaikutuksia tutkittaessa samaan tilavuuteen sijoitettiin eri kokoisia ja eri lukumäärä rekombinaattoreita. Siemens rekombinaattorimalli TONUS OD-ohjelmassa laskee vedynkulutuksen kuten oletettiin ja tulokset vahvistavat TONUS OD-ohjelman fysikaalisen laskennan luotettavuuden. Mahdollisia paikallisia jakautumia tutkitussa tilavuudessa ei voitu havaita LP-ohjelmalla, koska se käyttäälaskennassa suureiden tilavuuskeskiarvoja. Paikallisten jakautumien tutkintaan tarvitaan CFD -laskentaohjelma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pienitehoisessa taajuusmuuttajassa verkkojännite tasasuunnataan yleisesti diodisillalla. Taajuusmuuttajaa kuormitettaessa diodisilta aiheuttaa sen, että verkosta otettava virta on epäsinimuotoista ja sisältää runsaasti eri kertalukujen yliaaltoja. Tällainen virta vääristää verkon jännitettä sekä aiheuttaa häviöitä, resonansseja ja toimintaepävarmuutta sähkönjakeluverkkoon liitetyissä laitteissa ja komponenteissa. Työssä on tarkasteltu pienitehoisen kolmivaiheisen taajuusmuuttajan tulovirrassa esiintyviä yliaaltoja ja keinoja niiden rajoittamiseksi. Laitevalmistajien osalta syynä aiheen tutkimiseen ja kiinnostavuuteen ovat lähinnä uudet yliaaltoja käsittelevät standardit. Työssä onkin tutustuttu tarvittavin osin standardoinnin nykytilaan sekä seurattu standardeja valmistelevien työryhmien työtä ja tätä kautta perehdytty alaa käsittelevien standardien tulevaisuudennäkymiin Euroopan Unionin alueella. Käsittely on kohdistettu kolmivaiheisiin laitteisiin. Standardi IEC 61000-3-2 asettaa yliaaltorajat ammattikäyttöön tarkoitetuille laitteille, kun laitteen tuloteho on korkeintaan 1 kW. Tällä tehoalueella riittää kolmivaihelaitteille kuristimilla suoritettu passiivinen suodatus täyttämään asetetut viranomaisvaatimukset. Tähän liittyen on suunniteltu kolmivaihekuristin, joka on tarkoitettu käytettäväksi taajuusmuuttajasarjan lisävarusteena tehoalueella 0.12…2.2 kW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Turvallisuussuunnittelu muodostaa merkittävän osan ydinvoimalaitoksen suunnit-telutyöstä. Uusissa laitoskonsepteissa turvallisuutta on pyritty parantamaan lisää-mällä perinteisten aktiivisten hätäjärjestelmien rinnalle passiivisia eli toiminnal-taan puhtaasti luonnonlakeihin perustuvia hätäjärjestelmiä. Sähköteholtaan 640 MW oleva VVER-640 -laitostyyppi edustaa tässä suhteessa viimeisintä kehi-tysaskelta venäläisten VVER kevytvesireaktorien sarjassa. Suunnittelun lähtökoh-tana on ollut turvallisuuden parantaminen verrattuna aikaisempiin VVER-malleihin. Tähän on pyritty hätäjärjestelmien passiivisella toteutuksella. Passiivis-ten järjestelmien mitoitusperusteena on ollut laitoksen selviäminen itsenäisesti 24 tunnin ajan mahdollisissa onnettomuustilanteissa ilman suojarakennuksen tiiviy-den menetystä. Relap5-ohjelmalla tehtyjen simulointien perusteella laitoksen pas-siiviset järjestelmät näyttäisivät pystyvän huolehtimaan laitoksen turvallisuudesta sekä jäähdytteen- että sähkönmenetysonnettomuuksissa ilman aktiivisten järjes-telmien apua vaaditut 24 tuntia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Suunniteltiin ja rakennettiin suoraa vääntömomenttisäätöä soveltava taajuudenmuuttajakäyttö oikosulkumoottorin ohjaukseen korvaamaan passiivinen jarrukäyttö. Laite on kuntoutuslaite, jolla tehdään lihasvoiman mittauksia ja voimaharjoituksia. Selvitettiin kaupallisten moottoreiden ja taajuudenmuuttajien suoritusominaisuuksia ja tämän perusteella valittiin käyttöön sopivat laitteet. Työssä esitetään kaksi oikosulkumoottorin ohjaustapaa: vektorisäätö ja suora vääntömomenttisäätö. Merkittävin osa tästä työstä käsittelee - tarkan turvallisuussuunnitelman lisäksi - kuntoutuslaitteen prototyypin komponentteja, kokoamista ja suoritustestien tuloksia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uusissa ydinvoimalaitostyypeissä aiotaan käyttää aiempaa enemmän passiivisia turvallisuusjärjestelmiä. Näistä järjestelmistä on vielä vähän käyttökokemusta aktiivisiin turvallisuusjärjestelmiin verrattuna. Työssä tarkastellaan passiivisten turvallisuusjärjestelmien toimintaa sekä etsitään niiden mahdollisia luontaisia vikatilanteita. Luontaisten vikatilanteiden seurauksia järjestelmän suorituskykyyn arvioitiin yksinkertaisilla laskuilla ja mallintamalla RELAP5/MOD3.2.2 beta -termohydrauliikkaohjelmalla. Tarkastelu rajattiin kahden erityyppisen ydinvoimalaitoksen passiivisiin turvallisuusjärjestelmiin. Turvallisuusjärjestelmien suuntaa antavat mitat ja käyttötilanteiden parametrit saatiin laitosvalmistajien laitoskuvauksista. Osoittautui, että vikatilanteissa passiivisissa turvallisuusjärjestelmissä geometrialla on merkittävä vaikutus järjestelmän kapasiteettiin. Tarkasteluissa saatiin myös selville, että laitosmittakaavassa painovoimaisen hätälisävesijärjestelmän turvallisuustoiminto voi toteutua vaikka esiintyisi lyhytaikaisia toimintahäiriöitä, kuten lauhtumista hätälisävesisäiliössä. Sen sijaan lämmönsiirtopiirin virtausreittien tukkeutuminen voi olla fysikaalisesti merkittävä toimintaa haittaava tekijä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työn tavoitteena oli tutkia kilpa- ja harjoitusammuntaan käytettävällä haulikkoradalla käytettäväksi soveltuvia passiivisia meluntorjuntamenetelmiä ja suunnitella niistä toimiva kokonaisuus kohderadoille siten, että rata-alueen läheisillä asuinalueilla alitetaan 50 dB LAIMax-taso sekä muilla alueilla ampumaratamelun ohjearvot. Aluksi tarkasteltiin kohderatojen vanhoja menetelmiä ja radan meluntorjunnan kannalta olennaiset suunnat selvitettiin mittauksilla. Myös laukausmelun spektriä tutkittiin mittauksilla. Olemassa oleville menetelmille etsittiin korvaavia ja täydentäviä menetelmiä. Radan sijoittaminen maastoon on tärkeä osa meluntorjuntaa uutta rataa suunniteltaessa, mutta kohteena olleiden ratojen sijoittamista ei voitu enää muuttaa. Koska haulikkoammunnan säännöt eivät mahdollista aliääniammusten tai äänenvaimentimien käyttöä, ei varsinaista melupäästöä pystytä pienentämään. Melulle altistuvan kohteen sisätilojen suojaaminenkin on käytännössä hyödytöntä, koska ampumamelun ohjearvot ovat ulkoalueille. Ainoastaan melun absorptio, etenemisen estäminen ja ohjaaminen ovat kelvollisia menetelmiä kohderadoilla. Rata-alueelle suunniteltiin uudet ratojen väliset meluseinät, joiden ääneneristävyys ja -absorptio on vanhoja seiniä parempi. Taustavallille suunniteltiin jatkamista maavallina ja korottamista meluaitana, joka toimii myös haulienkierrätysjärjestelmän runkona. Alueen maaperä suunniteltiin muutettavaksi akustisesti pehmeämmäksi. Käytettävien menetelmien suunnittelussa tehtiin eri vaihtoehdoille laskennallisia arvioita, tietokonemallinnuksia ja laboratoriokokeita. Myös uusia menetelmiä haulikkoradan meluntorjunnassa tutkittiin. Tutkimusten perusteella näitä menetelmiä tutkitaan jatkossa käytännössä.