86 resultados para oily water treatment,

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Environmental accountability has become a major source of competitive advantage for industrial companies, because customers consider it as relevant buying criterion. However, in order to leverage their environmental responsibility, industrial suppliers have to be able to demonstrate the environmental value of their products and services, which is also the aim of Kemira, a global water chemistry company considered in this study. The aim of this thesis is to develop a tool which Kemira can use to assess the environmental value of their solutions for the customer companies in mining industry. This study answers to questions on what kinds of methods to assess environmental impacts exist, and what kind of tool could be used to assess the environmental value of Kemira’s water treatment solutions. The environmental impacts of mining activities vary greatly between different mines. Generally the major impacts include the water related issues and wastes. Energy consumption is also a significant environmental aspect. Water related issues include water consumption and impacts in water quality. There are several methods to assess environmental impacts, for example life cycle assessment, eco-efficiency tools, footprint calculations and process simulation. In addition the corresponding financial value may be estimated utilizing monetary assessment methods. Some of the industrial companies considered in the analysis of industry best practices use environmental and sustainability assessments. Based on the theoretical research and conducted interviews, an Excel based tool utilizing reference data on previous customer cases and customer specific test results was considered to be most suitable to assess the environmental value of Kemira’s solutions. The tool can be used to demonstrate the functionality of Kemira’s solutions in customers’ processes, their impacts in other process parameters and their environmental and financial aspects. In the future, the tool may be applied to fit also Kemira’s other segments, not only mining industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this master’s thesis is to analyze the mining industry customers' current and future needs for the water treatment services and discover new business development opportunities in the context of mine water treatment. In addition, the study focuses on specifying service offerings needed and evaluate suitable revenue generation models for them. The main research question of the study is: What kind of service needs related to water treatment can be identified in the Finnish mining industry? The literature examined in the study focused on industrial service classification and new service development process as well as the revenue generation of services. A qualitative research approach employing a case study method was chosen for the study. The present study uses customer and expert interviews as primary data source, complemented by archival data. The primary data was gathered by organizing total of 13 interviews, and the interviews were analyzed by using qualitative content analysis. The abductive-logic was chosen as the way of conducting scientific reasoning in this study. As a result, new service proposals were developed for Finnish mine industry suppliers. The main areas of development were on asset efficiency services and process support services. The service needs were strongly associated with suppliers’ know-how of water treatment process optimization, cost-effectiveness as well as on alternative technologies. The study provides an insight for managers that wish to pursue a water treatment services as a part of their business offering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent decades, industrial activity growth and increasing water usage worldwide have led to the release of various pollutants, such as toxic heavy metals and nutrients, into the aquatic environment. Modified nanocellulose and microcellulose-based adsorption materials have the potential to remove these contaminants from aqueous solutions. The present research consisted of the preparation of five different nano/microcellulose-based adsorbents, their characterization, the study of adsorption kinetics and isotherms, the determination of adsorption mechanisms, and an evaluation of adsorbents’ regeneration properties. The same well known reactions and modification methods that were used for modifying conventional cellulose also worked for microfibrillated cellulose (MFC). The use of succinic anhydride modified mercerized nanocellulose, and aminosilane and hydroxyapatite modified nanostructured MFC for the removal of heavy metals from aqueous solutions exhibited promising results. Aminosilane, epoxy and hydroxyapatite modified MFC could be used as a promising alternative for H2S removal from aqueous solutions. In addition, new knowledge about the adsorption properties of carbonated hydroxyapatite modified MFC as multifunctional adsorbent for the removal of both cations and anions ions from water was obtained. The maghemite nanoparticles (Fe3O4) modified MFC was found to be a highly promising adsorbent for the removal of As(V) from aqueous solutions due to its magnetic properties, high surface area, and high adsorption capacity . The maximum removal efficiencies of each adsorbent were studied in batch mode. The results of adsorption kinetics indicated very fast removal rates for all the studied pollutants. Modeling of adsorption isotherms and adsorption kinetics using various theoretical models provided information about the adsorbent’s surface properties and the adsorption mechanisms. This knowledge is important for instance, in designing water treatment units/plants. Furthermore, the correspondence between the theory behind the model and properties of the adsorbent as well as adsorption mechanisms were also discussed. On the whole, both the experimental results and theoretical considerations supported the potential applicability of the studied nano/microcellulose-based adsorbents in water treatment applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Water treatment using photocatalysis has gained extensive attention in recent years. Photocatalysis is promising technology from green chemistry point of view. The most widely studied and used photocatalyst for decomposition of pollutants in water under ultraviolet irradiation is TiO2 because it is not toxic, relatively cheap and highly active in various reactions. Within this thesis unmodified and modified TiO2 materials (powders and thin films) were prepared. Physico-chemical properties of photocatalytic materials were characterized with UV-visible spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectrometry (XPS), inductively coupled plasma optical emission spectroscopy (ICP-OES), ellipsometry, time-of-flight secondary ion mass spectrometry (ToF-SIMS), Raman spectroscopy, goniometry, diffuse reflectance measurements, thermogravimetric analysis (TGA) and nitrogen adsorption/desorption. Photocatalytic activity of prepared samples in aqueous environment was tested using model compounds such as phenol, formic acid and metazachlor. Also purification of real pulp and paper wastewater effluent was studied. Concentration of chosen pollutants was measured with high pressure liquid chromatography (HPLC). Mineralization and oxidation of organic contaminants were monitored with total organic carbon (TOC) and chemical oxygen demand (COD) analysis. Titanium dioxide powders prepared via sol-gel method and doped with dysprosium and praseodymium were photocatalytically active for decomposition of metazachlor. The highest degradation rate of metazachlor was observed when Pr-TiO2 treated at 450ºC (8h) was used. The photocatalytic LED-based treatment of wastewater effluent from plywood mill using commercially available TiO2 was demonstrated to be promising post-treatment method (72% of COD and 60% of TOC was decreased after 60 min of irradiation). The TiO2 coatings prepared by atomic layer deposition technique on aluminium foam were photocatalytically active for degradation of formic and phenol, however suppression of activity was observed. Photocatalytic activity of TiO2/SiO2 films doped with gold bipyramid-like nanoparticles was about two times higher than reference, which was not the case when gold nanospheres were used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää Suomenlahden rannalta merkittävän suuruisen alusöljyvahingon jälkeen kerättävän öljyisen jätteen käsittelymahdollisuudet ja -kapasiteetit sekä loppusijoitusmahdollisuudet ja -kapasiteetit Kymenlaakson alueen näkökulmasta. Tarkoituksena oli selvittää, missä jätteiden käsittely voidaan toteuttaa sekä, miten öljyisiä jätteitä voidaan esikäsitellä välivarastoinnin aikana puhdistuksen ja loppusijoituksen tehostamiseksi. Tutkimuksen kohteena oli sekä rannalta kerättävät kiinteät öljyiset ainekset että öljyinen merivesi. Työn alussa on perehdytty jätehuoltovastuuseen, eli kenen vastuulla öljyalusonnettomuuksissa syntyvät öljyiset jätteet ovat. Työssä on esitelty lyhyesti öljyvahinkojätteille teknisesti soveltuvien käsittelymenetelmien periaatteet ja menetelmien rajoituksia käsitellä öljyvahinkojätetteitä. Työssä on myös mainittu aiemmin Suomea koskettaneiden tai maailmalla tapahtuneiden alusöljyvahinkojen jätemääriä ja tapauksissa käytettyjä jätteiden käsittelymenetelmiä. Työ painottuu esittelemään Kymenlaakson alueen laitosten, Riihimäen Ekokem Oy Ab:n ja siirrettävien laitteistojen mahdollisuuksia käsitellä öljyisiä jätteitä. Lisäksi on esitelty öljyisen meriveden käsittelyyn soveltuvia laitoksia Kymenlaakson alueen näkökulmasta. Tietoja on kerätty puhelimitse ja sähköpostitse yritysten edustajilta vuoden 2007 aikana. Kymenlaakson alueella voidaan polttaa voimalaitosten leijupedeissä puhtaaseen polttoaineeseen sekoitettuja öljyisiä orgaanisia aineksia ja murskautuvia puhdistustyössä käytettyjä varusteita noin 10 000 t/a, homogenoitua öljyistä orgaanista ainesta voidaan polttaa Leca-soratehtaan rumpu-uunissa noin 1 200 t/a. Alueen polttokapasiteetti kasvaa, kun työn aikana rakenteilla oleva jätteenpolttolaitos valmistuu ja jätettä voidaan polttaa laitoksen arinalla. Haihtuvilla öljy-yhdisteillä pilaantuneita maa-aineksia voidaan alipainekäsitellä, jos yhdisteet eivät ole haihtuneet jo merellä. Erityisesti öljyiset maaainekset voidaan käsitellä alhaisilla öljypitoisuuksilla (öljypitoisuus noin alle 1-2 %) bitumistabiloimalla, aumakompostoimalla tai pesemällä siirrettävällä pesulaitteistolla. Kymenlaakson alueelle voidaan tuoda myös alueen ulkopuolelta siirrettäviä laitteistoja. Siirrettävät termodesorptiolaitteistot on tehty pilaantuneen maa-aineksen ensisijaiseen käsittelyyn, mutta samalla voidaan käsitellä myös muita jätejakeita, joilla on pieni partikkelikoko (alle 5-10 cm). Savaterra Oy:n siirrettävän termodesorptiolaitteiston kapasiteettiarvio on 100 000 t/a. Myös Niska & Nyyssönen Oy:llä on siirrettävä termodesorptiolaitteisto. Doranova Oy:n siirrettävän pesulaitteiston kapasiteettiarvio on 30 000- 50 000 t/a öljyistä maa-ainesta. Tutkimuksessa on ollut mukana myös Riihimäen Ekokem Oy Ab:n jätevoimala, jonka kapasiteettiarvio on 40 000-45 000 t/a erityisesti öljyisille orgaanisille aineksille, varusteille ja kuolleille eläimille. Riihimäen Ekokem Oy Ab:n ongelmajätelaitoksen rumpuuuneissa voidaan käsitellä arviolta 80 000-100 000 t/a öljyisiä maa-aineksia eli kiinteitä jätteitä, joiden partikkelikoko on suunnilleen alle 10 cm, ja 20 000 t/a nestemäisiä öljyisiä jätteitä. Työn loppupuolella on esitelty myös öljyisen meriveden käsittelyyn soveltuvia laitoksia ja niiden rajoituksia käsitellä kyseistä jätettä. Kyseisten laitosten kapasiteetit selviävät usein vasta onnettomuuden sattuessa. Kaikkiin annettuihin kapasiteettiarvioihin vaikuttaa merkittävästi jätteen koostumus. Raportin lopussa on esitelty alustava toimintasuunnitelma öljyvahinkojätteen käsittelemiseksi. Suunnitelmaan sisältyvät eri jätejakeille laaditut kaaviot, joista voi nähdä muun muassa eri jätekoostumuksille teknisesti soveltuvat käsittelymenetelmät ja käsittelymenetelmiä suorittavat yritykset. Öljyalusonnettomuuden sattuessa soveltuviin yrityksiin tulee ottaa yhteyttä ja selvittää kyseisellä hetkellä vapaana oleva käsittelykapasiteetti. Raportissa on myös esitelty käsittelykustannuksiin vaikuttavia tekijöitä ja arvioitu aiheutuvia kuljetuskustannuksia. Saadut tutkimustulokset ovat hyödynnettävissä erityisesti Kymenlaakson alueella. Tiedot käsittelymenetelmistä ja niiden rajoitteista ovat hyödynnettävissä valtakunnallisesti.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, information is published concerning Russian water and wastewater treatment plants. The information is based on a questionnaire sent to 70 water and wastewater treatment plants in 2012-2013. The questionnaire was prepared by the International Advanced Water Technologies Centre (IAWTC) and Lahti Development Company (LADEC). The questions dealt with an assessment of the present state, the need for changes, renovation, investments, and how to improve the efficiency of the operation by training and investments. A significant need to renew the old pipelines, constructions, and processes was clearly evident. The aggregated answers can be utilized in Russia as internal benchmarking in order to arrange training and plant visits, which were requested in many of the answers. Sharing this open report with the respondents can aid networking and awareness of HELCOM requirements which relate to waste water treatment plants discharging their waste water directly or indirectly into the Baltic Sea. The aim of this report is to provide information for Finnish small and medium size companies (SMEs) as regards possible water related exportation to different parts of Russia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Työn tavoitteena oli selvittää mitä käsittelyvaihtoehtoja on olemassa jäteveden puhdistamon tertiäärikäsittelyyn ja miten suuri tarve paperi- ja selluteollisuuden prosessivesien puhdistukseen on. Tarkoituksena oli saada käsitys koko tertiäärikäsittelystä eri näkökulmista. Lopuksi läpikäytiin tertiäärikäsittelymenetelmiä ja etsittiin mahdollisia uusia menetelmiä, joita voitaisiin käyttää jäteveden tertiääripuhdistukseen. Ensimmäisenä työssä on perehdytty jäteveden koostumukseen paperi- ja selluteollisuudessa ja puhdistukseen ilmastetulla aktiivilietemenetelmällä, jotta tertiäärikäsittely ymmärrettäisiin konseptina paremmin. Lisäksi työssä selvitettiin tertiäärikäsittelyn tarvetta ja vaihtoehtoja sen käyttämättä jättämiselle teollisuuden ja muun ympäristöä vahingoittavan toiminnan ympäristönäkökohdat huomioonottaen. Lyhyiden menetelmäesitysten jälkeen kiteytetään tertiäärikäsittelyn ympäristönäkökohdatja vaihtoehdot sen käytölle yhteenvetona, jossa otetaan huomioon myös viranomaisten, yrityksen ja BAT referenssien sisältämä tieto tertiäärikäsittelystä. Työn kokeellinen osa sisältää erään tertiäärikäsittelysovelluksenrakentamisen, koekäytön ja laboratorioanalyysien yhteenvedon. Lisäksi menetelmää verrataan kustannus-tehokkuudeltaan vastaavien menetelmien kanssa. Tarkoituksena oli löytää jäteveden tertiäärikäsittelyyn sopiva laitteisto, jonka toimintaanei sisältyisi kemikaalien annostelua ja sitä käytettäisiin lähinnä jätevedenpuhdistamon ongelmatilanteiden väliaikaiseksi ratkaisuksi. Mahdollisesti se voisi toimia myös jatkuvatoimisesti veden kirkastuksessa. Diplomityössä rakennettu laitteisto, jota käytettiin myös pilot koeajoissa, ei ollut paras mahdollinen laitteisto tertiäärikäsittelyn toteuttamiseksi paperi- ja selluteollisuudessa, mutta kilpailukykyinen muiden laitteistojen kanssa. Laitteiston toimintaperiaate on kuitenkin käyttökelpoinen tietyin varauksin ja sitä voidaan käyttää vedenpuhdistamiseen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Käytetyn voiteluöljyn regeneroinnissa muodostuu prosessivettä useista lähteistä. Tehokas päästöjenhallinta on yksi tärkeimmistä tavoitteista regenerointilaitoksen operoinnissa ja sen takia sitä tulee kehittää jatkuvasti entistä paremmaksi. Tavoitteisiin pääsemiseksi on oleellista tunnistaa vesienkäsittelyprosessin laadullinen massatase ja laadunvaihtelut ajotilanteiden mukaan. Työssä tutkitaan ja analysoidaan veden sisältämiä epäpuhtauksia sekä kirjallisuuslähteiden perusteella, että standardimenetelmillä ja modifioiduilla menetelmillä, joilla on akkreditointi. Analyysituloksista muodostetaan laadullinen massatase, josta nähdään epäpuhtauksien ja niitä kuvaavien parametrien kuormitukset kussakin prosessivesivirrassa. Tulosten perusteella arvioidaan nykyisen vesienkäsittelyn tehokkuutta, sen säätömahdollisuuksia ja kehitystarvetta. Tarkastelun ulkopuolelle kuitenkin jätetään vesienkäsittelystä ulosjohdettavan prosessiveden puhdistuslaitos. Tutkimusten perusteella regenerointilaitoksessa muodostuvien prosessivesien epäpuhtaudet koostuvat öljystä, BTEX-yhdisteistä, fenoliyhdisteistä, liuottimista, polttoaineiden ja voiteluöljyjen lisäaineista, typpi- ja rikkiyhdisteistä, metalliyhdisteistä sekä kiintoaineesta. Öljy jakautuu kevyisiin (C5-C10), keskiraskaisiin (C10-21) ja raskaisiin (C21-40) jakeisiin. Vesienkäsittelyssä suurin osa öljystä ja epäpuhtauksista saadaan erottumaan vedestä, jolloin puhdistuslaitokselle päätyy jäämäpitoisuudet öljyä, haihtuvia yhdisteitä sekä muita epäpuhtauksia. Puhdistuslaitosta kuormittavat eniten liuenneet orgaaniset yhdisteet sekä korkeaa kemiallista hapenkulutusta aiheuttavat epäorgaaniset yhdisteet (suolat), joiden erottamista prosessivesistä on syytä tulevaisuudessa kehittää.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chemical coagulation is commonly used in raw water and wastewater treatment plants for the destabilisation of pollutants so that they can be removed in the subsequent separation processes. The most commonly used coagulation chemicals are aluminium and iron metal salts. Electrocoagulation technology has also been proposed for the treatment of raw waters and wastewaters. With this technology, metal cations are produced on the electrodes via electrolysis and these cations form various hydroxides in the water depending on the water pH. In addition to this main reaction, several side reactions, such as hydrogen bubble formation and the reduction of metals on cathodes, also take place in the cell. In this research, the applications of electrocoagulation were investigated in raw water treatment and wastewater applications. The surface water used in this research contained high concentrations of natural organic matter (NOM). The effect of the main parameters – current density, initial pH, electric charge per volume, temperature and electrolysis cell construction – on NOM removal were investigated. In the wastewater treatment studies, the removal of malodorous sulphides and toxic compounds from the wastewaters and debarking effluents were studied. Also, the main parameters of the treatment, such as initial pH and current density, were investigated. Aluminium electrodes were selected for the raw water treatment, whereas wastewaters and debarking effluent were treated with iron electrodes. According to results of this study, aluminium is more suitable electrode material for electrocoagulation applications because it produces Al(III) species. Metal ions and hydroxides produced by iron electrodes are less effective in the destabilisation of pollutants because iron electrodes produce more soluble and less charged Fe(II) species. However, Fe(II) can be effective in some special applications, such as sulphide removal. The resulting metal concentration is the main parameter affecting destabilisation of pollutants. Current density, treatment time, temperature and electrolysis cell construction affect the dissolution of electrodes and hence also the removal of pollutants. However, it seems that these parameters have minimal significance in the destabilization of the pollutants besides this effect (in the studied range of parameters). Initial pH and final pH have an effect on the dissolution of electrodes, but they also define what aluminium or iron species are formed in the solution and have an effect on the ζ-potential of all charged species in the solution. According to the results of this study, destabilisation mechanisms of pollutants by electrocoagulation and chemical coagulation are similar. Optimum DOC removal and low residual aluminium can be obtained simultaneously with electrocoagulation, which may be a significant benefit of electrocoagulation in surface water treatment compared to chemical coagulation. Surface water treatment with electrocoagulation can produce high quality water, which could be used as potable water or fresh water for industrial applications. In wastewater treatment applications, electrocoagulation can be used to precipitate malodorous sulphides to prevent their release into air. Technology seems to be able to remove some toxic pollutants from wastewater and could be used as pretreatment prior to treatment at a biological wastewater treatment plant. However, a thorough economic and ecological comparison of chemical coagulation and electrocoagulation is recommended, because these methods seem to be similar in pollutant destabilisation mechanisms, metal consumption and removal efficiency in most applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Interest in water treatment by electrochemical methods has grown in recent years. Electrochemical oxidation has been applied particularly successfully to degrade different organic pollutants and disinfect drinking water. This study summarizes the effectiveness of the electrochemical oxidation technique in inactivating different primary biofilm forming paper mill bacteria as well as sulphide and organic material in pulp and paper mill wastewater in laboratory scale batch experiments. Three different electrodes, borondoped diamond (BDD), mixed metal oxide (MMO) and PbO2, were employed as anodes. The impact on inactivation efficiency of parameters such as current density and initial pH or chloride concentration of synthetic paper machine water was studied. The electrochemical behaviour of the electrodes was investigated by cyclic voltammetry with MMO, BDD and PbO2 electrodes in synthetic paper mill water as also with MMO and stainless steel electrodes with biocides. Some suggestions on the formation of different oxidants and oxidation mechanisms were also presented during the treatment. Aerobic paper mill bacteria species (Deinococcus geothermalis, Pseudoxanthomonas taiwanensis and Meiothermus silvanus) were inactivated effectively (>2 log) at MMO electrodes by current density of 50 mA/cm2 and the time taken three minutes. Increasing current density and initial chloride concentration of paper mill water increased the inactivation rate of Deinococcus geothermalis. The inactivation order of different bacteria species was Meiothermus silvanus > Pseudoxanthomonas taiwanensis > Deinococcus geothermalis. It was observed that inactivation was mainly due to the electrochemically generated chlorine/hypochlorite from chloride present in the water and also residual disinfection by chlorine/hypochlorite occurred. In real paper mill effluent treatment sulphide oxidation was effective with all the different initial concentrations (almost 100% reduction, current density 42.9 mA/cm2) and also anaerobic bacteria inactivation was observed (almost 90% reduction by chloride concentration of 164 mg/L and current density of 42.9 mA/cm2 in five minutes). Organic material removal was not as effective when comparing with other tested techniques, probably due to the relatively low treatment times. Cyclic voltammograms in synthetic paper mill water with stainless steel electrode showed that H2O2 could be degraded to radicals during the cathodic runs. This emphasises strong potential of combined electrochemical treatment with this biocide in bacteria inactivation in paper mill environments.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The acid mining drainage is considered the most significant environmental pollution problem around the world for the extensive formation acidic leachates containing heavy metals. Adsorption is widely used methods in water treatment due to it easy operation and the availability of a wide variety of commercial adsorbent (low cost). The primary goal of this thesis was to investigate the efficiency of neutralizing agents, CaCO3 and CaSiO3, and metal adsorption materials with unmodified limestone from Company Nordkalk Oy. In addition to this, the side materials of limestone mining were tested for iron adsorption from acidic model solution. This study was executed at Lappeenranta University of Technology, Finland. The work utilised fixed-bed adsorption column as the main equipment and large fluidized column. Atomic absorption spectroscopy (AAS) and x-ray diffraction (XRD) was used to determine ferric removal and the composition of material respectively. The results suggest a high potential for the studied materials to be used a low cost adsorbents in acid mine drainage treatment. From the two studied adsorbents, the FS material was more suitable than the Gotland material. Based on the findings, it is recommended that further studies might include detailed analysis of Gotland materials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tavallisten hapetusmenetelmien sijasta kehittyneitä hapetusmenetelmiä (AOP) on kehitetty yhä enemmän, jotta hapetusprosessista tulisi kannattavampi, tehokkaampi, ympäristöystävällisempi ja sitä voitaisiin hyödyntää laajalti eri paikoissa. Uusi teknologia, joka käyttää otsonia ja hydroksyyliradikaalia sähköimpulssien kanssa, on yksi mahdollinen tehokkaampi vedenkäsittelymentelmä. Kyseistä menetelmää kutsutaa pulsed corona discharge (PCD) -menetelmäksi, joka käyttää prosessissa muodostuvia otsonia ja hydroksyyliradikaalia hapettavina tekijöinä. Tässä työssä tutkittiin nitraatin muodostumista vedessä, kun vettä käsiteltiin PCD-laitteessa ja, kun oksalaatti- ja formaatti-ioneja oli sekoittuneina veteen. Nitraatteja muodostuu PCD–laitteessa veteen, kun ilman typpi reagoi hapettimina toimivien otsonin ja hydroksyyliradikaalin kanssa. Aiemmissa tutkimuksissa nitraatin muodostumisen on todistettu parantuvan, kun karboksyylihapot muurahais- ja oksaalihappo ovat sekoittuneina veteen. Tässä tutkimuksessa tarkoituksena oli tutkia, miten formaatti- ja oksalaatti-ionien, joiden pitoisuudet olivat 0 ppm, 50 ppm ja 100 ppm, läsnäolo vedessä vaikuttaa nitraatin muodostumiseen. PCD-kokeista saadut näytteet analysoitiin ionikromatografilla. Kyseisessä tutkimuksessa nitraatin muodostuminen oli samansuuruista jokaisessa kokeessa hapetusajan kasvaessa samalla, kun otettujen näytteiden pH-arvot laskivat. Tuloksena voitiin pitää sitä, ettei formaatti- tai oksalaatti-ioneilla ollut vaikutusta nitraatti-ionien muodostumiseen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Increasing demand and shortage of energy resources and clean water due to the rapid development of industry, population growth and long term droughts have become an issue worldwide. As a result, global warming, long term droughts and pollution-related diseases are becoming more and more serious. The traditional technologies, such as precipitation, neutralization, sedimentation, filtration and waste immobilization, cannot prevent the pollution but restrict the waste chemicals only after the pollution emission. Meanwhile, most of these treatments cannot thoroughly degrade the contaminants and may generate toxic secondary pollutants into ecosystem. Heterogeneous photocatalysis as the innovative wastewater technology attracts many attention, because it is able to generate highly reactive transitory species for total degradation of organic compounds, water pathogens and disinfection by-products. Semiconductor as photocatalysts have demonstrated their efficiency in degrading a wide range of organics into readily biodegradable compounds, and eventually mineralized them to innocuous carbon dioxide and water. But, the efficiency of photocatalysis is limited, and hence, it is crucial issue to modify photocatalyst to enhance photocatalytic activity. In this thesis, first of all, two literature views are conducted. A survey of materials for photocatalysis has been carried out in order to summarize the properties and the applications of photocatalysts that have been developed in this field. Meanwhile, the strategy for the improvement of photocatalytic activity have been explicit discussed. Furthermore, all the raw material and chemicals used in this work have been listed as well as a specific experimental process and characterization method has been described. The synthesize methods of different photocatalysts have been depicted step by step. Among these cases, different modification strategies have been used to enhance the efficiency of photocatalyst on degradation of organic compounds (Methylene Blue or Phenol). For each case, photocatalytic experiments have been done to exhibit their photocatalytic activity.The photocatalytic experiments have been designed and its process have been explained and illustrated in detailed. Moreover, the experimental results have been shown and discussion. All the findings have been demonstrated in detail and discussed case by case. Eventually, the mechanisms on the improvement of photocatalytic activities have been clarified by characterization of samples and analysis of results. As a conclusion, the photocatalytic activities of selected semiconductors have been successfully enhanced via choosing appropriate strategy for the modification of photocatalysts.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thesis focuses on the water chemistry of the experimental test facilities and their reference VVER reactors. The main objective of the thesis is to provide recommendations for water chemistry management for laboratory facilities (VEERA, PACTEL) simulating the VVERs and for the large future facilities of the Lappeenranta University of Technology. In the beginning, the concept of nuclear power generation and the applicability of the nuclear power usage is discussed. Next, different water chemistry and water purification systems in primary and secondary circuits currently used at the power plant have been outlined. Also the construction geometry and design of test facilities PACTEL and VEERA, as well as the operation principles of their main equipment has been described. Finally, the appropriate water chemistry and water treatment system have been proposed for the existing and future experimental facilities of LUT.