61 resultados para fault current limiter

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent Storms in Nordic countries were a reason of long power outages in huge territories. After these disasters distribution networks' operators faced with a problem how to provide adequate quality of supply in such situation. The decision of utilization cable lines rather than overhead lines were made, which brings new features to distribution networks. The main idea of this work is a complex analysis of medium voltage distribution networks with long cable lines. High value of cable’s specific capacitance and length of lines determine such problems as: high values of earth fault currents, excessive amount of reactive power flow from distribution to transmission network, possibility of a high voltage level at the receiving end of cable feeders. However the core tasks was to estimate functional ability of the earth fault protection and the possibility to utilize simplified formulas for operating setting calculations in this network. In order to provide justify solution or evaluation of mentioned above problems corresponding calculations were made and in order to analyze behavior of relay protection principles PSCAD model of the examined network have been created. Evaluation of the voltage rise in the end of a cable line have educed absence of a dangerous increase in a voltage level, while excessive value of reactive power can be a reason of final penalty according to the Finish regulations. It was proved and calculated that for this networks compensation of earth fault currents should be implemented. In PSCAD models of the electrical grid with isolated neutral, central compensation and hybrid compensation were created. For the network with hybrid compensation methodology which allows to select number and rated power of distributed arc suppression coils have been offered. Based on the obtained results from experiments it was determined that in order to guarantee selective and reliable operation of the relay protection should be utilized hybrid compensation with connection of high-ohmic resistor. Directional and admittance based relay protection were tested under these conditions and advantageous of the novel protection were revealed. However, for electrical grids with extensive cabling necessity of a complex approach to the relay protection were explained and illustrated. Thus, in order to organize reliable earth fault protection is recommended to utilize both intermittent and conventional relay protection with operational settings calculated by the use of simplified formulas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä tutkitaan maasulkuvirtoja sekä niiden vaikutusta ja kehitystä Haminan Ener-gia Oy:n keskijänniteverkossa. Lisäksi tarkastellaan erilaisia mahdollisuuksia rajoittaa maasulkuvirtojen suuruuksia. Tutkimusalueena käytetään koko Haminan Energia Oy:n keskijänniteverkkoaluetta. Maasulkuvirtojen suuruuden ja vaikutusten tutkimiseksi suori-tetaan erilaisin lähtökriteerein maasulkujen vikavirtalaskennat verkkotietojärjestelmällä. Verkon kehittymisen analysoimiseksi selvitetään sen ikätietoja, kaava-alueiden muutok-sia sekä päämuuntaja- ja varasyöttökapasiteetteja. Analyysien pohjalta saatujen tulosten perusteella työssä laaditaan arvio maasulkuvirtojen kehityksestä tulevaisuudessa. Maasulkuvirtojen kompensoimiseksi päädytään rakenta-maan uusi päämuuntaja Laurilan sähköasemalle sekä parantamaan eräiden muuntamoiden ja erottimien maadoituksia. Nämä parannusehdotukset toteuttamalla pystytään sähkötur-vallisuusmääräykset täyttämään maasulkujen osalta pitkälle tulevaisuuteen sekä vähentä-mään asiakkaiden kokemia keskeytyksiä. Lisäksi työssä tehdään ohjeistus Haminan Energia Oy:lle maasulkuvirtojen laskentaa varten.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thesis talks about relay protection for microgrids. Microgrid operation sets more challenges than traditional utility grid protection because of lower fault current levels. Solutions for these challenges are discussed in this paper. Thesis also studies available relay protection solutions and figures out how they would fit for microgrid protection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sähkömarkkinalakimuutokset ovat ohjanneet useita verkkoyhtiötä muuttamaan investoin-tistrategioitaan. Kiristyneet toimitusvarmuusvaatimukset edellyttävät useilta verkkoyh-tiöiltä aiempaa suurempaa panostusta jakeluverkon kehittämiseksi. Toimitusvarmuusvaa-timusten täyttäminen edellyttää myös merkittäviä muutoksia verkkoyhtiöiden käyttämiin verkostotekniikoihin. Suurhäiriöille alttiita ilmajohtoja muutetaan verkkoyhtiöissä totuttua nopeammalla aikataululla maakaapeleiksi tiukentuneiden toimitusvarmuusvaatimusten täyttämiseksi. PKS Sähkönsiirto Oy:n 20 kV sähköverkko on ollut suurimmalta osalta avojohtoverkkoa jossa toimitusvarmuus ei ole nykyisellään muuttuneen sähkömarkkinalain asettamalla ta-solla. Tämä on johtanut verkostostrategian luomiseen, jossa yhtenä toimena toimitusvar-muuden lisäämiseksi vaaditulle tasolle on avojohtolinjojen korvaaminen maakaapeleilla. Maakaapelointien nopea rakennusaikataulu tuo monia haasteita verkkoyhtiöille. Maakaa-pelointien korkea maasulkuvirran ja loistehon tuotto verrattuna avojohtoverkkoon tulee huomioida yhtiössä verkkoa rakennettaessa. Tässä diplomityössä selvitetään PKS Sähkönsiirto Oy:n verkostostrategian mukaisten maakaapelointien vaikutuksia sähköverkolle. Työssä on arvioitu tavoiteverkon mukaisten maakaapeleiden aiheuttamaa maasulkuvirran ja loistehon tuoton tasoa. Tulosten perusteel-la on tehty johtopäätökset mihin verkkoyhtiön on kiinnitettävä huomioita kaapelointeja suunnitellessa ja toteuttaessa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most common reason for a low-voltage induction motor breakdown is a bearing failure. Along with the increasing popularity of modern frequency converters, bearing failures have become the most important motor fault type. Conditions in which bearing currents are likely to occur are generated as a side effect of fast du/dt switching transients. Once present, different types of bearing currents can accelerate the mechanical wear of bearings by causing deformation of metal parts in the bearing and degradation of the lubricating oil properties.The bearing current phenomena are well known, and several bearing current measurement and mitigation methods have been proposed. Nevertheless, in order to develop more feasible methods to measure and mitigate bearing currents, better knowledge of the phenomena is required. When mechanical wear is caused by bearing currents, the resulting aging impact has to be monitored and dealt with. Moreover, because of the stepwise aging mechanism, periodically executed condition monitoring measurements have been found ineffective. Thus, there is a need for feasible bearing current measurement methods that can be applied in parallel with the normal operation of series production drive systems. In order to reach the objectives of feasibility and applicability, nonintrusive measurement methods are preferred. In this doctoral dissertation, the characteristics and conditions of bearings that are related to the occurrence of different kinds of bearing currents are studied. Further, the study introduces some nonintrusive radio-frequency-signal-based approaches to detect and measure parameters that are associated with the accelerated bearing wear caused by bearing currents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Korkealla virranvoimakkuudella tainnutettujen broilereiden rintafileen irroitushetken vaikutus lihaksen leikkausvoiman vastukseen, pH:hon, keittohävikkiin ja väriin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Maatalous- ja elintarviketieteiden www-pohjaiset viitetietokannat ja aihehakemistot - suomalaisen tiedonetsijän näkökulma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of condition monitoring of electric motors has been wide for several decades. The research and development at universities and in industry has provided means for the predictive condition monitoring. Many different devices and systems are developed and are widely used in industry, transportation and in civil engineering. In addition, many methods are developed and reported in scientific arenas in order to improve existing methods for the automatic analysis of faults. The methods, however, are not widely used as a part of condition monitoring systems. The main reasons are, firstly, that many methods are presented in scientific papers but their performance in different conditions is not evaluated, secondly, the methods include parameters that are so case specific that the implementation of a systemusing such methods would be far from straightforward. In this thesis, some of these methods are evaluated theoretically and tested with simulations and with a drive in a laboratory. A new automatic analysis method for the bearing fault detection is introduced. In the first part of this work the generation of the bearing fault originating signal is explained and its influence into the stator current is concerned with qualitative and quantitative estimation. The verification of the feasibility of the stator current measurement as a bearing fault indicatoris experimentally tested with the running 15 kW induction motor. The second part of this work concentrates on the bearing fault analysis using the vibration measurement signal. The performance of the micromachined silicon accelerometer chip in conjunction with the envelope spectrum analysis of the cyclic bearing faultis experimentally tested. Furthermore, different methods for the creation of feature extractors for the bearing fault classification are researched and an automatic fault classifier using multivariate statistical discrimination and fuzzy logic is introduced. It is often important that the on-line condition monitoring system is integrated with the industrial communications infrastructure. Two types of a sensor solutions are tested in the thesis: the first one is a sensor withcalculation capacity for example for the production of the envelope spectra; the other one can collect the measurement data in memory and another device can read the data via field bus. The data communications requirements highly depend onthe type of the sensor solution selected. If the data is already analysed in the sensor the data communications are needed only for the results but in the other case, all measurement data need to be transferred. The complexity of the classification method can be great if the data is analysed at the management level computer, but if the analysis is made in sensor itself, the analyses must be simple due to the restricted calculation and memory capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Virranmittausantureita tarvitaan monenlaisissa käyttökohteissa, joissa ne mittaavat sekä virran suuruuttaettä laatua ja toimivat osana niiden säätelyjärjestelmää. Virranmittausantureita tarvitaan myös vikatilanteiden määrittämiseen erilaisissa suojauspiireissä. Taajuusmuuttajissa virranmittaus on hyvin tärkeää ja suurista virroista sekä taajuuksista johtuen se täytyy suunnitella huolella. Tässä diplomityössä käsitellään ja tutkitaan eri virranmittausmenetelmiä, joiden avulla taajuusmuuttajan luotettava virranmittaus voidaan toteuttaa. Työssä tutkitaan eri menetelmiä virranmittauksen toteuttamiseksi, minkä jälkeen niistä valitaan sopiva menetelmä ja tutkitaan sen eri toteutusvaihtoehtoja. Sopivan toteutusvaihtoehdon valinnan jälkeen työssä suunnitellaan oma virranmittausanturi, joka sopii nimenomaisesti taajuusmuuttajakäyttöön. Suunnitellun anturin ominaisuuksia tutkitaan lopuksi simuloimalla, jonka jälkeen arvioidaan sen soveltumista käytännön sovelluksiin sekä arvioidaan erilaisia keinoja sen parantamiseksi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin sähkön laatua Suur-Savon Sähkön verkossa. Samalla perehdyttiin sähkönjakeluverkkojen aiheuttamiin ympäristövaikutuksiin ja näiden vähentämiseen. Työn aihealue on aika laaja kokonaisuus, eikä mihinkään perehdytä kovin yksityiskohtaisella tasolla, vaan käsitellään asiaa mahdollisimman laajasti monelta eri näkökantilta käytännönläheisesti. Mietittäessä keinoja parantaa sähkönlaatua alettiin yhtiössä pohtimaan keinoja vähentää 20 kV avojohtoverkon määrääja osana tätä keskustelua kehitettiin 1000 voltin jakelu-järjestelmä, jonka ensimmäiset koekohteet otettiin käyttöön vuonna 2001. Järjestelmä on osoittautunut käyttökelpoiseksi ja toimivaksi varsinkin vapaa-ajan asuntojen sähköistämisessä. Osana tulevaisuuden verkostostrategiaa joudutaan Suur-Savon Sähkössäkin pohtimaan maasulkuvirtojen kompensointia ja myös tätä aihealuetta onkäsitelty työn yhteydessä. Sähkön laatu on erittäin riippuvainen luonnon aiheuttamista vioista ja näiltä suojautuminen vaatii nykyisen avojohtoverkon korvaamista jollain muulla johtoratkaisulla, joka nostaa maasulkuvirran arvoa ja johtaa jossain vaiheessa kompensoinnin käyttöön.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On selvää, että tänä päivänä maailmankaupan painopiste on hiljalleen siirtymässä Aasiaan ja varsinkin Kiina on ollut huomion keskipisteessä. Erityisesti valmistavien yritysten perspektiivistä muutos on ollut merkittävä ja tämä tosiasia kasvattaa yrityksissä paineita luoda kustannustehokkaita toimitusketjuratkaisuja,joiden vasteaika on mahdollisimman lyhyt. Samaan aikaan kun tarkastellaan kuljetusvirtoja, huomattaan että maanosien välillä on suuri epätasapaino. Tämä on enimmäkseen seurausta suurten globaalisti toimivien yritysten toimitusketjustrategioista. Useimmat näistä toimijoista optimoivat verkostonsa turvautumalla 'paikalliseen hankintaan', jotta he voisivat paremmin hallita toimitusketjujaan ja saada näitä reagointiherkimmiksi. Valmistusyksiköillä onkin monesti Euroopassa pakko käyttää kalliita raaka-aineita ja puolivalmisteita. Kriittisiksi tekijöiksi osoittautuvat kuljetus- ja varastointikustannukset sekä näiden seurauksena hukka-aika, joka aiheutuu viivästyksistä. Voidakseen saavuttaa optimiratkaisun, on tehtävä päätös miten tuotteet varastoidaan: keskitetysti tai hajautetusti ja integroida tämä valinta sopivien kuljetusmuotojen kanssa. Aasiasta Pohjois-Eurooppaan on halpaa käyttää merikuljetusta, mutta operaatio kestää hyvin pitkään - joissain tapauksessa jopa kahdeksan viikkoa. Toisaalta lentokuljetus on sekä kallis että rajoittaa siirrettävien tuotteiden eräkokoa.On olemassa kolmaskin vaihtoehto, josta voisi olla ratkaisuksi: rautatiekuljetus on halvempi kuin lentokuljetus ja vasteajat ovat lyhyemmät kuin merikuljetuksissa. Tässä tutkimuksessa tilannetta selvitetään kyselyllä, joka suunnattiin Suomessa ja Ruotsissa toimiville yrityksille. Tuloksien perusteella teemme johtopäätökset siitä, mitkä kuljetusmuotojen markkinaosuudet tulevat olemaan tulevaisuudessa sekä luomme kuvan kuljetusvirroista Euroopan, Venäjän, Etelä-Korea, Intian, Kiinan ja Japanin välillä. Samalla on tarkoitus ennakoida sitä, miten tarkastelun kohteena olevat yritykset aikovat kehittää kuljetuksiaan ja varastointiaan tulevien vuosien aikana. Tulosten perusteella näyttää siltä, että seuraavan viiden vuoden kuluessa kuljetuskustannukset eivät merkittävissä määrin tule muuttuman ja meri- sekä kumipyöräkuljetukset pysyvät suosituimpina vaihtoehtoina.Kuitenkin lentokuljetusten osuus laskee hiukan, kun taas rautatiekuljetusten painotus kasvaa. Tulokset paljastavat, että Kiinassa ja Venäjällä kuljetettava konttimäärä kasvaa; Intiassa tulos on saman suuntainen, joskaan ei niin voimakas. Analyysimme mukaan kuljetusvirtoihin liittyvä epätasapaino säilyy Venäjän kuljetusten suhteen: yritykset jatkavat tulevaisuudessakin vientiperusteista strategiaansa. Varastoinnin puolella tunnistamme pienemmän muutoksen, jonka mukaan pienikokoisten varastojen määrät todennäköisesti vähenevät tulevaisuudessa ja kiinnostus isoja varastoja kohtaan lisääntyy. Tässä kohtaa on mainittava, että suomalaisilla yrityksillä on enemmän varastoja Keski- ja Itä-Euroopassa verrattuna ruotsalaisiin toimijoihin, jotka keskittyvät selkeämmin Länsi-Euroopan maihin. Varastoja yrityksillä on molemmissa tapaukissa paljolti kotimaassaan. Valitessaan varastojensa sijoituskohteita yritykset painottavat seuraavia kriteereitä: alhaiset jakelukustannukset, kokoamispaikan/valmistustehtaan läheisyys, saapuvan logistiikan integroitavuus ja saatavilla olevat logistiikkapalvelut. Tutkimuksemme lopussa päädymme siihen, että varastojen sijoituspaikat eivät muutu satamien rakenteen ja liikenneyhteyksien takia kovinkaan nopeasti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.