16 resultados para Sewage treatment and disposal
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
The problem concerning livestock waste handling in the Leningrad region has been subjected to a number of research works. However, the requirements for use of manure and sewage sludge as well as for treatment processes are not certain. So, this problem remains relevant and, therefore, further investigation ought to be made. Currently a large amount of sewage sludge and manure is generated in the Leningrad region. These livestock wastes have to be obligatory treated. The most common methods for treatment in the region, such as anaerobic digestion, composting and aging as well as the most potential methods are described in the thesis. The most potential methods for the Leningrad region are anaerobic digestion, composting and combustion. Each method has strengths and weaknesses, which are also considered in the paper. Aging was not considered as potential treatment method because it does not meet the sanitary and epidemiological requirements. Furthermore, the work gives an overview and comparison of Finnish and Russian legislative and normative acts concerning livestock wastes handling. On the whole the requirements of the Russian Federation concerning sewage sludge and manure are not much different from the Finnish ones.
Resumo:
In Finland the thermal treatment of sewage sludge has been moderate in 21th century. The reason has been the high moisture content of sludge. During 2005-2008, 97-99% of sewage sludge was utilized in landscaping and agriculture. However agricultural use has been during 2005-2007 less than 3 %. The aim of national waste management plan is that by 2016 100% of sludge is used either as soil amendment or energy. The most popular utilization method for manure is spreading it on arable land. The dry manures such as poultry manure and horse manure could also be used in incineration. The ashes could be used as fertilizers and while it is not suitable as a starter fertilizer, it is suitable in maintaining P levels in the soil. One of the main drivers for more efficient nutrient management is the eutrophication in lakes and the Baltic See. ASH DEC process can be used in concentrating phosphorus rich ashes while separating the heavy metals that could be included. ASH DEC process uses thermochemical treatment to produce renewable phosphate for fertilizer production. The process includes mixing of ashes and chlorine donors and subsequent treatment in rotary kiln for 20 min in temperature of 900 – 1 050 oC. The heavy metals evaporate and P-rich product is obtained. The toxic substances are retained in air pollution control system in form of mixed metal hydroxides. The aim of conducting this study is to estimate the potential of ASH DEC process in treating phosphorus rich ashes in Finland. The masses considered in are sewage sludge, dry manure from horses, and poultry and liquid pig manure. To date the usual treatment method for sewage sludge in Finland is composting or anaerobic digestion. Part of the amount of produced sewage sludge (800 kt/a fresh mass and 160 kt/a TS) could also be incinerated and the residual ashes used in ASH DEC process. Incinerating only manure can be economically difficult to manage because the incineration of manure is in Finland considered as waste incineration. Getting a permit for waste incineration is difficult and also small scale waste incineration is too expensive. The manure could act as an additional feedstock in counties with high density of animal husbandry where the land area might not be enough for spreading of manure. Now when the manure acts as a supplementary feedstock beside sludge, the ash can’t be used directly as fertilizer. Then it could be used in ASH DEC process. The perquisite is that the manure producers could pay for the incineration, which might prove problematic.
Resumo:
Background: The burden of influenza on children is substantial. Although mortality rates are low, the incidence of influenza is highest in children, among whom also complications are frequent. A more accurate recognition of influenza in children could enable the rational use of antiviral drugs and help to avoid unnecessary courses of antibiotics. Limited data exists on the efficacy of oseltamivir treatment and the trivalent inactivated influenza vaccine (TIV) in children. Aims and methods: We sought for signs and symptoms that could help clinicians to diagnose influenza on clinical grounds in a case-control study in children <13 years of age. We further assessed the feasibility of different diagnostics methods during the early stage of the illness in children aged 1-3 years. The efficacy of early oseltamivir treatment (started <24h from the onset of symptoms) was evaluated in a randomized controlled trial (RCT) conducted in children 1-3 years of age, and the effectiveness of TIV to prevent laboratory-confirmed influenza was determined in a prospective, observational cohort study conducted among children aged 9 months to 3 years of age. Results: Fever was the only symptom predicting influenza in children. The sensitivity of conventionally used laboratory methods to detect influenza during the first 24h of illness was 92%. The sensitivity of the influenza rapid test in the same setting was 90% for influenza A and 25% for influenza B. Early oseltamivir treatment shortened the duration of the illness in children with influenza A by 3.5-4.0 days, but no efficacy was observed against influenza B. The effectiveness of TIV was 84% against the wellmatched influenza A, while no effectiveness against the mismatched influenza B was observed. Conclusions: Laboratory diagnostics are needed for a reliable diagnosis of influenza in children and were found sensitive already during the early stage of the illness. Early oseltamivir treatment was highly effective against influenza A, but no efficacy was seen against influenza B. TIV is effective also in young children if a good match between the vaccine and circulating strain is achieved.
Resumo:
The efficient use of materials and natural recourses, for ecological and economic reasons, has become more and more important in all industries. In the forest industries this means higher levels of closure in the material circulations of the mills. One possibility to reduce wastewater discharge is to re-use part of the 2nd clarifier effluent as process water. The main target of this thesis was to evaluate the technical suitability of several mechanical and chemical tertiary treatment methods for water re-use. Some of the tested methods seemed to have high potential for the removal of some specific constituents from the wastewater. Tertiary treatment is needed because higher levels of closure may cause problems with increasing amounts of non-process elements in different points of kraft pulp process. The aspect of sustainable development was taken into account by evaluating positive and negative environmental effects of the treatment processes. Environmental benefits can be gained by using some of the tertiary treatment methods tested. These methods should still be researched more for system optimization.
Resumo:
Operation of pulp and paper mills generates waste including wastewater treatment sludge and deinking sludge. Both sludge types are generated in large amounts and are mainly disposed of in landfills in the Leningrad Region resulting in environmental degradation. The thesis was aimed at seeking new sustainable ways of sludge utilization. Two paper mills operating in the Leningrad Region and landfilling their sludge were identified: “SCA Hygiene Products Russia” and “Knauf”. The former generates 150 t/day of deinking sludge, the latter – 145 t/day of secondary sludge. Chemical analyses of deinking sludge were performed to assess applicability of sludge in construction materials production processes. Higher heating value on dry basis of both sludge types was determined to evaluate energy potential of sludge generated in the Leningrad Region. Total energy output from sludge incineration was calculated. Deinking sludge could be utilized in the production process of “LSR-Cement” or “Slantsy Cement Plant Cesla” factories, and “Pobeda” and “Nikolsky” brick mills without exceeding current sludge management costs.
Resumo:
Intrahepatic cholestasis of pregnancy (ICP) is a pregnancy-specific disorder characterized by maternal pruritus and elevated liver enzymes. It usually begins in the third trimester of pregnancy and resolves spontaneously after delivery. ICP is considered benign for the pregnant woman, but it is associated with an increased risk for unexplained term stillbirth and preterm delivery. There are no specific laboratory markers to diagnose ICP. The diagnosis is currently based on the presence of maternal pruritus and elevated values of alanine aminotransaminases (ALT) and serum bile acids (BA). Recently, ursodeoxycholic acid (UDCA) has been used for treatment. Mechanisms leading to intrauterine fetal death (IUFD) may be multifactorial and are unknown at present. For this thesis, 415 pregnant women with ICP were studied. The aim was to evaluate the value of the liver enzyme glutathione S-transferase alpha (GSTA) as a specific marker of ICP and to assess the effect of maternal UDCA therapy on maternal laboratory values and fetal outcome. The specific markers predisposing the fetus to heart arrhythmia were studied by comparing waveform analysis of fetal electrocardiograms (FECG) during labor in pregnancies complicated by ICP with controls. The levels of maternal GSTA were high and the values correlated with the value of ALT in patients with ICP. UDCA therapy reduced the values of the liver enzymes and alleviated maternal pruritus, but it did not influence maternal hormonal values. Although the newborns experienced an uneventful perinatal outcome, severe ICP was still associated with preterm birth and admission to the neonatal intensive care unit (NICU). There were no significant differences in intrapartum FECG findings between fetuses born to ICP women and controls.
Resumo:
The nutrient load to the Gulf of Finland has started to increase as a result of the strong economic recovery in agriculture and livestock farming in the Leningrad region. Also sludge produced from municipal wastewater treatment plant of the Leningrad region causes the great impact on the environment, but still the main options for its treatment is disposal on the sludge beds or Landfills. The aim of this study was to evaluate the implementation of possible joint treatment methods of manure form livestock and poultry enterprises and sewage sludge produced from municipal wastewater treatment plants in the Leningrad region. The study is based on published data. The most attention was put on the anaerobic digestion and incineration methods. The manure and sewage sludge generation for the whole Leningrad region and energy potential produced from their treatment were estimated. The calculations showed that total amount of sewage sludge generation is 1 348 000 t/a calculated on wet matter and manure generation is 3 445 000 t/a calculated on wet matter. The potential heat release from anaerobic digestion process and incineration process is 4 880 000 GJ/a and 5 950 000 GJ/a, respectively. Furthermore, the work gives the overview of the general Russian and Finnish legislation concerning manure and sewage sludge treatment. In the Gatchina district it was chosen the WWTP and livestock and poultry enterprises for evaluation of the centralized treatment plant implementation based on anaerobic digestion and incineration methods. The electricity and heat power of plant based on biogas combustion process is 4.3 MW and 7.8 MW, respectively. The electricity and heat power of plant based on manure and sewage sludge incineration process is 3.0 MW and 6.1 MW, respectively.
Resumo:
Rising population, rapid urbanisation and growing industrialisation have severely stressed water quality and its availability in Malawi. In addition, financial and institutional problems and the expanding agro industry have aggravated this problem. The situation is worsened by depleting water resources and pollution from untreated sewage and industrial effluent. The increasing scarcity of clean water calls for the need for appropriate management of available water resources. There is also demand for a training system for conceptual design and evaluation for wastewater treatment in order to build the capacity for technical service providers and environmental practitioners in the country. It is predicted that Malawi will face a water stress situation by 2025. In the city of Blantyre, this situation is aggravated by the serious pollution threat from the grossly inadequate sewage treatment capacity. This capacity is only 23.5% of the wastewater being generated presently. In addition, limited or non-existent industrial effluent treatment has contributed to the severe water quality degradation. This situation poses a threat to the ecologically fragile and sensitive receiving water courses within the city. This water is used for domestic purposes further downstream. This manuscript outlines the legal and policy framework for wastewater treatment in Malawi. The manuscript also evaluates the existing wastewater treatment systems in Blantyre. This evaluation aims at determining if the effluent levels at the municipal plants conform to existing standards and guidelines and other associated policy and regulatory frameworks. The raw material at all the three municipal plants is sewage. The typical wastewater parameters are Biochemical Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), and Total Suspended Solids (TSS). The treatment target is BOD5, COD, and TSS reduction. Typical wastewater parameters at the wastewater treatment plant at MDW&S textile and garments factory are BOD5 and COD. The treatment target is to reduce BOD5 and COD. The manuscript further evaluates a design approach of the three municipal wastewater treatment plants in the city and the wastewater treatment plant at Mapeto David Whitehead & Sons (MDW&S) textile and garments factory. This evaluation utilises case-based design and case-based reasoning principles in the ED-WAVE tool to determine if there is potential for the tool in Blantyre. The manuscript finally evaluates the technology selection process for appropriate wastewater treatment systems for the city of Blantyre. The criteria for selection of appropriate wastewater treatment systems are discussed. Decision support tools and the decision tree making process for technology selection are also discussed. Based on the treatment targets and design criteria at the eight cases evaluated in this manuscript in reference to similar cases in the ED-WAVE tool, this work confirms the practical use of case-based design and case-based reasoning principles in the ED-WAVE tool in the design and evaluation of wastewater treatment 6 systems in sub-Sahara Africa, using Blantyre, Malawi, as the case study area. After encountering a new situation, already collected decision scenarios (cases) are invoked and modified in order to arrive at a particular design alternative. What is necessary, however, is to appropriately modify the case arrived at through the Case Study Manager in order to come up with a design appropriate to the local situation taking into account technical, socio-economic and environmental aspects. This work provides a training system for conceptual design and evaluation for wastewater treatment.
Resumo:
Original sludge from wastewater treatment plants (WWTPs) usually has a poor dewaterability. Conventionally, mechanical dewatering methods are used to increase the dry solids (DS) content of the sludge. However, sludge dewatering is an important economic factor in the operation of WWTPs, high water content in the final sludge cake is commonly related to an increase in transport and disposal costs. Electro‐dewatering could be a potential technique to reduce the water content of the final sludge cake, but the parameters affecting the performance of electro‐dewatering and the quality of the resulting sludge cake, as well as removed water, are not sufficiently well known. In this research, non‐pressure and pressure‐driven experiments were set up to investigate the effect of various parameters and experimental strategies on electro‐dewatering. Migration behaviour of organic compounds and metals was also studied. Application of electrical field significantly improved the dewatering performance in comparison to experiments without electric field. Electro‐dewatering increased the DS content of the sludge from 15% to 40 % in non‐pressure applications and from 8% to 41% in pressure‐driven applications. DS contents were significantly higher than typically obtained with mechanical dewatering techniques in wastewater treatment plant. The better performance of the pressure‐driven dewatering was associated to a higher current density at the beginning and higher electric field strength later on in the experiments. The applied voltage was one of the major parameters affecting dewatering time, water removal rate and DS content of the sludge cake. By decreasing the sludge loading rate, higher electrical field strength was established between the electrodes, which has a positive effect on an increase in DS content of the final sludge cake. However interrupted voltage application had anegative impact on dewatering in this study, probably because the off‐times were too long. Other factors affecting dewatering performance were associated to the original sludge characteristics and sludge conditioning. Anaerobic digestion of the sludge with high pH buffering capacity, polymer addition and freeze/thaw conditioning had a positive impact on dewatering. The impact of pH on electro‐dewatering was related to the surface charge of the particles measured as zeta‐potential. One of the differences between electro‐dewatering and mechanical dewatering technologies is that electro‐dewatering actively removes ionic compounds from the sludge. In this study, dissolution and migration of organic compounds (such as shortchain fatty acids), macro metals (Na, K, Ca, Mg, Fe) and trace metals (Ni, Mn, Zn, Cr) was investigated. The migration of the metals depended on the fractionation and electrical field strength. These compounds may have both negative and positive impacts on the reuse and recycling of the sludge and removed water. Based on the experimental results of this study, electro‐dewatering process can be optimized in terms of dewatering time, desired DS content, power consumption and chemical usage.
Resumo:
Surgery is the cornerstone of ovarian cancer treatment and maximal cytoreduction is important. In the early 1980’s primary surgical treatment of ovarian cancer was performed in over 80 hospitals in Finland. The significance of the operative volume of the hospital, of the training of the surgeons and of centralization of surgical treatment has been widely discussed. The aim of the present study was to evaluate the outcome of surgical treatment of ovarian cancer in different hospital categories retrospectively and prospectively, and to analyze if any differences are reflected in survival. The retrospective study included 3851 ovarian cancer patients operated between 1983 and 1994 in Finland. The data was analyzed according to hospital category (university, central, and other) and by quartiles of the hospital operative volume. The results showed that patients operated in the highest operative volume hospitals had the best relative survival. When stratifying the analysis by the period of diagnosis (1983-1988 and 1989-1994), the university hospitals improved their performance the most. The prospective part of the thesis was initiated in 1999 and included 307 patients with invasive ovarian cancer and 65 patients with an ovarian borderline tumor. The baseline and 5-year surveys used a questionnaire that was filled in by the operating surgeons. For analysis of the 5-year followup data, the hospitals were divided into three categories (<10, 10-20, or >20 patients operated in 1999). The effect of the surgical volume was analyzed also as a continuous variable (1-47 operations per year). In university hospitals, pelvic lymphadenectomy was performed in 88 %, and para-aortic lymphadenectomy in 73 %, of the patients with stage I disease. The corresponding figures ranged from 11 % to 21 % in the other hospitals. For stage III ovarian cancer patients operated by gynecological oncologists, the estimated odds ratio for no macroscopic residual tumor was 3.0 times higher (95 % CI 1.2-7.5) than for those operated by general gynecologists. In the university and other hospitals 82% of the patients received platinum-based chemotherapy. Platinum + taxane combination was given to 63 % of the patients in the university and in 49 % in the other hospitals (p = 0.0763). Only a minority of the patients with tumors of borderline malignancy were staged according to recommendations, most often multiple peritoneal biopsies and omentectomy were neglected. FIGO stage, patient age, and residual tumor were independent prognostic factors of cancer-specific 5-year survival. A higher hospital operative volume was also a significant prognostic factor for better cancer-specific survival (p = 0.036) and disease-free survival (p = 0.048). In conclusion, ovarian cancer patients operated in high-volume university hospitals were more often optimally debulked and had a significantly better cancer-specific survival than patients operated in other hospitals. These results favor centralization of primary surgical treatment of ovarian cancer.
Resumo:
Pumppauksessa arvioidaan olevan niin teknisesti kuin taloudellisestikin huomattavia mahdollisuuksia säästää energiaa. Maailmanlaajuisesti pumppaus kuluttaa lähes 22 % sähkö-moottorien energiantarpeesta. Tietyillä teollisuudenaloilla jopa yli 50 % moottorien käyttämästä sähköenergiasta voi kulua pumppaukseen. Jäteveden pumppauksessa pumppujen toiminta perustuu tyypillisesti on-off käyntiin, jolloin pumpun ollessa päällä se käy täydellä teholla. Monissa tapauksissa pumput ovat myös ylimitoitettuja. Yhdessä nämä seikat johtavat kasvaneeseen energian kulutukseen. Työn teoriaosassa esitellään perusteet jätevesihuollosta ja jäteveden käsittelystä sekä pumppaussysteemin pääkomponentit: pumppu, putkisto, moottori ja taajuusmuuttaja. Työn empiirisessä osassa esitellään työn aikana kehitetty laskuri, jonka avulla voidaan arvioida energiansäästöpotentiaalia jäteveden pumppaussysteemeissä. Laskurilla on mandollista laskea energiansäästöpotentiaali käytettäessä pumpun tuoton ohjaustapana pyörimisnopeuden säätöä taajuusmuuttajalla on-off säädön sijasta. Laskuri ilmoittaa optimaalisimmanpumpun pyörimisnopeuden sekä ominaisenergiankulutuksen. Perustuen laskuriin, kolme kunnallista jätevedenpumppaamoa tutkittiin. Myös laboratorio-testitsuoritettiin laskurin simuloimiseksi sekä energiansäästöpotentiaalin arvioimiseksi. Tutkimukset osoittavat, että jätevedenpumppauksessa on huomattavia mandollisuuksia säästää energiaa pumpun pyörimisnopeutta pienentämällä. Geodeettisen nostokorkeuden ollessa pieni, voidaan energiaa säästää jopa 50 % ja pitkällä aikavälillä säästö voi olla merkittävä. Tulokset vahvistavat myös tarpeen jätevedenpumppaussysteemien toiminnan optimoimiseksi.
Resumo:
Tällä hetkellä suuri osa esikäsiteltyjen jätevesilietteiden loppusijoitusvaihtoehdoista ei pysty kattamaan lopullisesti kasvavien lietemäärien loppusijoitustarvetta, mikä lisää lietteen loppusijoitusta kaatopaikoille. Kuitenkin EU:n tiukentuneen jätehuoltolainsäädännön sekä ilmastonlämpenemisen suurien haasteiden vuoksi, kaatopaikoille sijoitettavien jätteiden määrää täytyy pyrkiä vähentämään. Tämän työn tavoitteena on tutkia jätevedenpuhdistamoilta tulevan lietteen termistä kuivausta yhtenä lietteenkäsittely vaihtoehtona. Tavoitteena on selvittää voidaanko lietettä kuivaamalla saada liete paremmin hyödynnetyksi. Työssä tarkasteltiin yleisesti yhdyskuntalietteen termisessä kuivaamisessa nykyisin käytettäviä menetelmiä, sen ympäristövaikutuksia, energian tarvetta ja kustannuksia sekä siitä saatavaa hyötyä lietteen loppusijoittamisessa. Lisäksi arvioitiin kuinka kaatopaikkakaasun hyödyntäminen soveltuisi lietteen kuivauksessa tarvittavan energian tuotantoon. Työssä tehdyn selvityksen mukaan kaatopaikkakaasua voidaan hyödyntää suhteellisen helposti lämmöntuotannossa ilman merkittäviä laitosmuutoksia tai kaasun puhdistusta. Ongelmana pidettiin kaatopaikkakaasun kuljetuksia, joka on suhteellisen vaikeaa ja taloudellisesti kannattamatonta. Kuitenkin noin 10 km välimatkan säteellä kaatopaikasta sen hyödyntäminen olisi mahdollista. Työn laskelmien mukaan Suomessa hukkaan poltetulla kaatopaikkakaasulla voitaisiin kuivata noin 250 tuhatta tonnia lietettä vuosittain.
Resumo:
Chemical coagulation is commonly used in raw water and wastewater treatment plants for the destabilisation of pollutants so that they can be removed in the subsequent separation processes. The most commonly used coagulation chemicals are aluminium and iron metal salts. Electrocoagulation technology has also been proposed for the treatment of raw waters and wastewaters. With this technology, metal cations are produced on the electrodes via electrolysis and these cations form various hydroxides in the water depending on the water pH. In addition to this main reaction, several side reactions, such as hydrogen bubble formation and the reduction of metals on cathodes, also take place in the cell. In this research, the applications of electrocoagulation were investigated in raw water treatment and wastewater applications. The surface water used in this research contained high concentrations of natural organic matter (NOM). The effect of the main parameters – current density, initial pH, electric charge per volume, temperature and electrolysis cell construction – on NOM removal were investigated. In the wastewater treatment studies, the removal of malodorous sulphides and toxic compounds from the wastewaters and debarking effluents were studied. Also, the main parameters of the treatment, such as initial pH and current density, were investigated. Aluminium electrodes were selected for the raw water treatment, whereas wastewaters and debarking effluent were treated with iron electrodes. According to results of this study, aluminium is more suitable electrode material for electrocoagulation applications because it produces Al(III) species. Metal ions and hydroxides produced by iron electrodes are less effective in the destabilisation of pollutants because iron electrodes produce more soluble and less charged Fe(II) species. However, Fe(II) can be effective in some special applications, such as sulphide removal. The resulting metal concentration is the main parameter affecting destabilisation of pollutants. Current density, treatment time, temperature and electrolysis cell construction affect the dissolution of electrodes and hence also the removal of pollutants. However, it seems that these parameters have minimal significance in the destabilization of the pollutants besides this effect (in the studied range of parameters). Initial pH and final pH have an effect on the dissolution of electrodes, but they also define what aluminium or iron species are formed in the solution and have an effect on the ζ-potential of all charged species in the solution. According to the results of this study, destabilisation mechanisms of pollutants by electrocoagulation and chemical coagulation are similar. Optimum DOC removal and low residual aluminium can be obtained simultaneously with electrocoagulation, which may be a significant benefit of electrocoagulation in surface water treatment compared to chemical coagulation. Surface water treatment with electrocoagulation can produce high quality water, which could be used as potable water or fresh water for industrial applications. In wastewater treatment applications, electrocoagulation can be used to precipitate malodorous sulphides to prevent their release into air. Technology seems to be able to remove some toxic pollutants from wastewater and could be used as pretreatment prior to treatment at a biological wastewater treatment plant. However, a thorough economic and ecological comparison of chemical coagulation and electrocoagulation is recommended, because these methods seem to be similar in pollutant destabilisation mechanisms, metal consumption and removal efficiency in most applications.