10 resultados para Low-rise Residential Buildings
em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland
Resumo:
In this bachelor’s thesis are examined the benefits of current distortion detection device application in customer premises low voltage networks. The purpose of this study was to find out if there are benefits for measuring current distortion in low-voltage residential networks. Concluding into who can benefit from measuring the power quality. The research focuses on benefits based on the standardization in Europe and United States of America. In this research, were also given examples of appliances in which current distortion detection device could be used. Along with possible illustration of user interface for the device. The research was conducted as an analysis of the benefits of current distortion detection device in residential low voltage networks. The research was based on literature review. The study was divided to three sections. The first explain the reasons for benefitting from usage of the device and the second portrays the low-cost device, which could detect one-phase current distortion, in theory. The last section discuss of the benefits of usage of current distortion detection device while focusing on the beneficiaries. Based on the result of this research, there are benefits from usage to the current distortion detection device. The main benefitting party of the current distortion detection device was found to be manufactures, as they are held responsible of limiting the current distortion on behalf of consumers. Manufactures could adjust equipment to respond better to the distortion by having access to on-going current distortion in network. The other benefitting party are system operators, who would better locate distortion issues in low-voltage residential network to start prevention of long-term problems caused by current distortion early on.
Resumo:
Tämän diplomityön tavoitteena oli vertailla paikallisia energiantuotantovaihtoehtoja eri-tyisesti lämmöntuotantoon painottuen. Tarkastelu sovitettiin uuden matalaenergiarakentamista vastaavan kerrostaloasuinalueen tarpeisiin. Näkökulmana olivat sekä taloudellisuus että hiilidioksidipäästöt. Yksityiskohtaisemman tarkastelun kohteena olivat maalämpö, alueellinen biolämpölaitos sekö alueellinen pien-CHP-laitos. Perusvaihtoehtona tutkittiin kaukolämpöä. Kaikkiin vaihtoehtoihin kuului myös kapasiteetiltaan rajoitettu jäähdytys. Tulosten mukaan kokonaistaloudellisin vaihtoehto oli maalämpö yhdistettynä kaukolämpöön. Tässä vaihtoehdossa peruslämpö tuotetaan maalämmöllä, mutta huippu-lämpöön sekä käyttöveden lämmitykseen käytetään kaukolämpöä. Ratkaisulla saadaan aikaan myös päästövähennyksiä kaukolämpöön verrattuna. Tulosten mukaan pienimmät päästöt olivat pien-CHP-biovoimalaitoksella. Toisaalta nykyisillä sähkön myyntihinnoilla pienimuotoinen yhdistetty sähkön ja lämmön tuotanto ei pysty kilpailemaan kustannusrakenteensa puolesta muiden tutkittujen vaihtoehtojen kanssa.
Resumo:
Työn tavoitteena oli saada selville ketkä ovat uuden tuotteen, eli kotihissin asiakkaat. Mitkä ovat tuotteen mahdollisuudet Suomen markkinoilla ja onko markkinoilla odotettavissa kasvua, sekä miten tähän mahdolliseen kasvuun päästäisiin käsiksi. Kotihissin ominaisuudet vaikuttavat siihen, että se on tarkoitettu asennettavaksi yksityisiin pientaloihin. Uuden tuotteen ansiosta KONE voi liittää nykyiseen vahvaan toimialaansa, eli kerrostaloihin, uuden aluevaltauksen; Pientalot. Tämä 'laajentuminen' tuo mukanaan kuluttajamarkkinoiden haasteet. Markkinatilanteen selvittämiseen käyttin jo olemassa olevaa tietoa hyväkseni; sanomalehdistä markkinatutkimuksiin. Asiakasryhmät kartoitin tutustumalla messutapahtumissa saatuihin kontakteihin. Päätutkimusmenetelmänä käytin haastatteluja. Niihin osallistui kaikkiaan 14 vastaajaa. He vasatsivat kysymyksiin ostomotiiveista ja tuotteesta. Eräs haastattelujen tärkeimmistä teemoista liittyi yhteydenpito- ja jakelukanaviin, joista 12 vastaajaa antoivat mielipiteitään. Työni tulokset viittaavat siihen, että markkinatilanne näyttää positiiviselta KONEen kannalta. Tutkimuksesta sain selville kotihissin asiakassegmentit ja myös miten nämä potentiaaliset asiakkaat saadaan tehokkaimmin tavoitettua.
Resumo:
Mitoitukseen on olemassa standardoitu laskentamenetelmä, mutta se ei yksistään ole riittävä jäähdytettävän lattiarakenteen suunnitteluun. Rakenteen lämpötilajakaumaa jäähdytystilanteessa tutkittiin lisäksi FDM-ohjelmistolla tehdyillä simuloinneilla. Lattiajäähdytyksessä kosteuden tiivistymisen riski ja mukavuustekijät rajoittavat käytettävissä olevaa lämpötilaa. Saavutettavissa olevan teho on puolestaan suoraan riippuvainen jäähdytettävän tilan ja jäähdyttävän pinnan välisestä lämpötilaerosta. Kirjallisuudesta, standardeista ja aiemmasta tutkimuksesta etsittiin tietoa jäähdytetyn lattian vaikutuksesta asumismukavuuteen sekä kosteusteknisessä mielessä käytettävissä oleva lämpötila-alue. Asuintiloissa lattiapinnan minimilämpötila on 19 °C, millä lattiarakenteesta ja materiaaleista riippuen päästään 20 - 30 W/m2 jäähdytystehoihin. Järjestelmän säätömahdollisuuksia selvitettiin kirjallisuudesta ja vaihtoehtoisia toteutustapoja, sekä niihin tarvittavia komponentteja on esitelty työn loppuosassa.
Resumo:
Matalaenergiarakentaminen asettaa uudenlaisia haasteita ja mahdollisuuksia lämpöenergian tuotannolle. Lämmitysjärjestelmien mitoitustehot eivät laske samassa suhteessa kuin lämmitysenergiankulutus, mikä suosii alhaisia investointeja muuttuvien kulujen kustannuksella. Työssä tutkittiin viittä vaihtoehtoista tapaa tuottaa kohdealueen rakennuskannan vuotuinen lämpöenergiantarve. Kohdealue koostui pääasiallisesti matalaenergiakerrostaloista. Neljä vaihtoehtoa perustui kaukolämpöön ja yksi matalaenergiaverkkoon varustettuna kiinteistökohtaisilla lämpöpumpuilla. Lähialueen jätevedenpuhdistamolle sijoitettu keskitetty lämpöpumppuratkaisu muodostui kokonaiskustannuksiltaan edullisimmaksi vaihtoehdoksi tuottaa kohdealueen rakennuskannan lämpöenergiantarve. Haketta polttoaineenaan käyttävä pien-CHPlaitos omasi vastaavasti pienimmän hiilijalanjäljen, mutta oli kustannusrakenteeltaan epäedullinen. Kohdealue ja vaihtoehtoiset lämmitysjärjestelmät mallinnettiin GaBi 4.3 elinkaarimallinnusohjelmistolla vaihtoehtojen hiilijalanjälkien selvittämiseksi.
Resumo:
Tässä työssä tutkittiin lämpöpumppujärjestelmiä, joilla tuotetaan samaan aikaan kylmä- ja lämpötehoa. Höyryn puristus lämpöpumppu on yleisimmin käytetty lämpöpumpputyyppi ja sen pääkomponentit ovat kompressori, lauhdutin, paisuntaventtiili ja höyrystin. Lämpöpumppu tuottaa samaan aikaan kylmätehoa höyrystimellä ja lämpötehoa lauhduttimella. Lämpöpumpun toiminta-arvoihin vaikuttaa valittujen lämpötilatasojen lisäksi voimakkaasti valitun kiertoaineen termodynaamiset ominaisuudet sekä kompressorin painesuhteeseen verrannollinen isentrooppihyötysuhde. Uusissa lämpöpumpuissa käytetään HFC yhdisteitä sekä sekoituksia kiertoaineina, mutta myös luonnolliset aineet, kuten ammoniakki, ovat lupaavia korvikkeita CFC yhdisteille. Sopivia sovelluskohteita kylmä- ja lämpötehon yhteistuotannolle ovat kauppa- ja asuinrakennukset, hotellit, toimistot, elintarviketeollisuus ja -myymälät sekä vierekkäiset jää- ja uimahallit ja hiihtoputket. Kylmä- ja lämpötehon yhteistuotannolla voitaisiin saavuttaa merkittäviä säästöjä ja päästövähennyksiä. Esimerkiksi jäähallien kylmäkoneiden lauhdelämmön hyödyntämisessä olisi Suomessa potentiaalia 6-10 miljoonan euron vuotuisiin säästöihin. Kylmä- ja lämpötehon yhteistuotanto voidaan toteuttaa hyödyntämällä kylmäkoneen lauhdelämpöä toisella lämpöpumpulla. Toinen vaihtoehto on käyttää eri tilojen samanaikaiseen lämmittämiseen ja jäähdyttämiseen HPS lämpöpumppua tai moniyksikköistä lämpöpumppua.
Resumo:
This thesis was carried out as a case study of a company YIT in order to clarify the sev-erest risks for the company and to build a method for project portfolio evaluation. The target organization creates new living environment by constructing residential buildings, business premises, infrastructure and entire areas worth for EUR 1.9 billion in the year 2013. Company has noted project portfolio management needs more information about the structure of project portfolio and possible influences of market shock situation. With interviews have been evaluated risks with biggest influence and most appropriate metrics to examine. The major risks for the company were evaluated by interviewing the executive staff. At the same time, the most appropriate risk metrics were considered. At the moment sales risk was estimated to have biggest impact on company‟s business. Therefore project port-folio evaluation model was created and three different scenarios for company‟s future were created in order to identify the scale of possible market shock situation. The created model is tested with public and descriptive figures of YIT in a one-year-long market shock and the impact on different metrics was evaluated. Study was conducted using con-structive research methodology. Results indicate that company has notable sales risk in certain sections of business portfolio.
Resumo:
Smart home implementation in residential buildings promises to optimize energy usage and save significant amount of energy simply due to a better understanding of user's energy usage profile. Apart from the energy optimisation prospects of this technology, it also aims to guarantee occupants significant amount of comfort and remote control over home appliances both at home locations and at remote places. However, smart home investment just like any other kind of investment requires an adequate measurement and justification of the economic gains it could proffer before its realization. These economic gains could differ for different occupants due to their inherent behaviours and tendencies. Thus it is pertinent to investigate the various behaviours and tendencies of occupants in different domain of interests and to measure the value of the energy savings accrued by smart home implementations in these domains of interest in order to justify such economic gains. This thesis investigates two domains of interests (the rented apartment and owned apartment) for primarily two behavioural tendencies (Finland and Germany) obtained from observation and corroborated by conducted interviews to measure the payback time and Return on Investment (ROI) of their smart home implementations. Also, similar measures are obtained for identified Australian use case. The research finding reveals that building automation for the Finnish behavioural tendencies seems to proffers a better ROI and payback time for smart home implementations.
Resumo:
The growing population in cities increases the energy demand and affects the environment by increasing carbon emissions. Information and communications technology solutions which enable energy optimization are needed to address this growing energy demand in cities and to reduce carbon emissions. District heating systems optimize the energy production by reusing waste energy with combined heat and power plants. Forecasting the heat load demand in residential buildings assists in optimizing energy production and consumption in a district heating system. However, the presence of a large number of factors such as weather forecast, district heating operational parameters and user behavioural parameters, make heat load forecasting a challenging task. This thesis proposes a probabilistic machine learning model using a Naive Bayes classifier, to forecast the hourly heat load demand for three residential buildings in the city of Skellefteå, Sweden over a period of winter and spring seasons. The district heating data collected from the sensors equipped at the residential buildings in Skellefteå, is utilized to build the Bayesian network to forecast the heat load demand for horizons of 1, 2, 3, 6 and 24 hours. The proposed model is validated by using four cases to study the influence of various parameters on the heat load forecast by carrying out trace driven analysis in Weka and GeNIe. Results show that current heat load consumption and outdoor temperature forecast are the two parameters with most influence on the heat load forecast. The proposed model achieves average accuracies of 81.23 % and 76.74 % for a forecast horizon of 1 hour in the three buildings for winter and spring seasons respectively. The model also achieves an average accuracy of 77.97 % for three buildings across both seasons for the forecast horizon of 1 hour by utilizing only 10 % of the training data. The results indicate that even a simple model like Naive Bayes classifier can forecast the heat load demand by utilizing less training data.
Resumo:
Permanent magnet generators (PMG) represent the cutting edge technology in modern wind mills. The efficiency remains high (over 90%) at partial loads. To improve the machine efficiency even further, every aspect of machine losses has to be analyzed. Additional losses are often given as a certain percentage without providing any detailed information about the actual calculation process; meanwhile, there are many design-dependent losses that have an effect on the total amount of additional losses and that have to be taken into consideration. Additional losses are most often eddy current losses in different parts of the machine. These losses are usually difficult to calculate in the design process. In this doctoral thesis, some additional losses are identified and modeled. Further, suggestions on how to minimize the losses are given. Iron losses can differ significantly between the measured no-load values and the loss values under load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction adds losses to the stator iron by manipulating the harmonic content of the flux. It was, therefore, re-evaluated that in salient pole machines, to minimize the losses and the loss difference between the no-load and load operation, the flux density has to be kept below 1.5 T in the stator yoke, which is the traditional guideline for machine designers. Eddy current losses may occur in the end-winding area and in the support structure of the machine, that is, in the finger plate and the clamping ring. With construction steel, these losses account for 0.08% of the input power of the machine. These losses can be reduced almost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be subjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. Winding losses can rise rapidly when high frequencies and 10–15 mm high conductors are used. In general, minimizing the winding losses is simple. For example, it can be done by dividing the conductor into transposed subconductors. However, this comes with the expense of an increase in the DC resistance. In the doctoral thesis, a new method is presented to minimize the winding losses by applying a litz wire with noninsulated strands. The construction is the same as in a normal litz wire but the insulation between the subconductors has been left out. The idea is that the connection is kept weak to prevent harmful eddy currents from flowing. Moreover, the analytical solution for calculating the AC resistance factor of the litz-wire is supplemented by including an end-winding resistance in the analytical solution. A simple measurement device is developed to measure the AC resistance in the windings. In the case of a litz-wire with originally noninsulated strands, vacuum pressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases studied, the VPI affected the AC resistance factor, but in the other case, it did not have any effect. However, more research is needed to determine the effect of the VPI on litz-wire with noninsulated strands. An empirical model is developed to calculate the AC resistance factor of a single-layer formwound winding. The model includes the end-winding length and the number of strands and turns. The end winding includes the circulating current (eddy currents that are traveling through the whole winding between parallel strands) and the main current. The end-winding length also affects the total AC resistance factor.