28 resultados para Local blood flow measurement

em Doria (National Library of Finland DSpace Services) - National Library of Finland, Finland


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous studies have demonstrated that clinical pulpal pain can induce the expression of pro-inflammatory neuropeptides in the adjacent gingival crevice fluid (GCF). Vasoactive agents such as substance P (SP) are known to contribute to the inflammatory type of pain and are associated with increased blood flow. More recent animal studies have shown that application of capsaicin on alveolar mucosa provokes pain and neurogenic vasodilatation in the adjacent gingiva. Pain-associated inflammatory reactions may initiate expression of several pro- and anti-inflammatory mediators. Collagenase-2 (MMP-8) has been considered to be the major destructive protease, especially in the periodontitis-affected gingival crevice fluid (GCF). MMP-8 originates mostly from neutrophil leukocytes, the first line of defence cells that exist abundantly in GCF, especially in inflammation. With this background, we wished to clarify the spatial extensions and differences between tooth-pain stimulation and capsaicin-induced neurogenic vasodilatation in human gingiva. Experiments were carried out to study whether tooth stimulation and capsaicin stimulation of alveolar mucosa would induce changes in GCF MMP-8 levels and whether tooth stimulation would release neuropeptide SP in GCF. The experiments were carried out on healthy human volunteers. During the experiments, moderate and high intensity painful tooth stimulation was performed by a constant current tooth stimulator. Moderate tooth stimulation activates A-delta fibres, while high stimulation also activates C-fibres. Painful stimulation of the gingiva was achieved by topical application of capsaicin-moistened filter paper on the mucosal surface. Capsaicin is known to activate selectively nociceptive C-fibres of stimulated tissue. Pain-evoked vasoactive changes in gingivomucosal tissues were mapped by laser Doppler imaging (LDI), which is a sophisticated and non-invasive method for studying e.g. spatial and temporal characteristics of pain- and inflammation-evoked blood flow changes in gingivomucosal tissues. Pain-evoked release of MMP-8 in GCF samples was studied by immunofluorometric assay (IFMA) and Western immunoblotting. The SP levels in GCF were analysed by Enzyme immunoassay (EIA). During the experiments, subjective stimulus-evoked pain responses were determined by a visual analogue pain scale. Unilateral stimulation of alveolar mucosa and attached gingiva by capsaicin evoked a distinct neurogenic vasodilatation in the ipsilateral gingiva, which attenuated rapidly at the midline. Capsaicin stimulation of alveolar mucosa provoked clear inflammatory reactions. In contrast to capsaicin stimuli, tooth stimulation produced symmetrical vasodilatations bilaterally in the gingiva. The ipsilateral responses were significantly smaller during tooth stimulation than during capsaicin stimuli. The current finding – that tooth stimulation evokes bilateral vasodilatation while capsaicin stimulation of the gingiva mainly produces unilateral vasodilatation – emphasises the usefulness of LDI in clarifying spatial features of neurogenic vasoactive changes in the intra-oral tissues. Capsaicin stimulation of the alveolar mucosa induced significant elevations in MMP-8 levels and activation in GCF of the adjacent teeth. During the experiments, no marked changes occurred in MMP-8 levels in the GCF of distantly located teeth. Painful stimulation of the upper incisor provoked elevations in GCF MMP-8 and SP levels of the stimulated tooth. The GCF MMP-8 and SP levels of the non-stimulated teeth were not changed. These results suggest that capsaicin-induced inflammatory reactions in gingivomucosal tissues do not cross the midline in the anterior maxilla. The enhanced reaction found during stimulation of alveolar mucosa indicates that alveolar mucosa is more sensitive to chemical irritants than the attached gingiva. Analysis of these data suggests that capsaicin-evoked neurogenic inflammation in the gingiva can trigger the expression and activation of MMP-8 in GCF of the adjacent teeth. In this study, it is concluded that experimental tooth pain at C-fibre intensity can induce local elevations in MMP-8 and SP levels in GCF. Depending on the role of MMP-8 in inflammation, in addition to surrogated tissue destruction, the elevated MMP-8 in GCF may also reflect accelerated local defensive and anti-inflammatory reactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Virtually every cell and organ in the human body is dependent on a proper oxygen supply. This is taken care of by the cardiovascular system that supplies tissues with oxygen precisely according to their metabolic needs. Physical exercise is one of the most demanding challenges the human circulatory system can face. During exercise skeletal muscle blood flow can easily increase some 20-fold and its proper distribution to and within muscles is of importance for optimal oxygen delivery. The local regulation of skeletal muscle blood flow during exercise remains little understood, but adenosine and nitric oxide may take part in this process. In addition to acute exercise, long-term vigorous physical conditioning also induces changes in the cardiovasculature, which leads to improved maximal physical performance. The changes are largely central, such as structural and functional changes in the heart. The function and reserve of the heart’s own vasculature can be studied by adenosine infusion, which according to animal studies evokes vasodilation via it’s a2A receptors. This has, however, never been addressed in humans in vivo and also studies in endurance athletes have shown inconsistent results regarding the effects of sport training on myocardial blood flow. This study was performed on healthy young adults and endurance athletes and local skeletal and cardiac muscle blod flow was measured by positron emission tomography. In the heart, myocardial blood flow reserve and adenosine A2A receptor density, and in skeletal muscle, oxygen extraction and consumption was also measured. The role of adenosine in the control of skeletal muscle blood flow during exercise, and its vasodilator effects, were addressed by infusing competitive inhibitors and adenosine into the femoral artery. The formation of skeletal muscle nitric oxide was also inhibited by a drug, with and without prostanoid blockade. As a result and conclusion, it can be said that skeletal muscle blood flow heterogeneity decreases with increasing exercise intensity most likely due to increased vascular unit recruitment, but exercise hyperemia is a very complex phenomenon that cannot be mimicked by pharmacological infusions, and no single regulator factor (e.g. adenosine or nitric oxide) accounts for a significant part of exercise-induced muscle hyperemia. However, in the present study it was observed for the first time in humans that nitric oxide is not only important regulator of the basal level of muscle blood flow, but also oxygen consumption, and together with prostanoids affects muscle blood flow and oxygen consumption during exercise. Finally, even vigorous endurance training does not seem to lead to supranormal myocardial blood flow reserve, and also other receptors than A2A mediate the vasodilator effects of adenosine. In respect to cardiac work, atheletes heart seems to be luxuriously perfused at rest, which may result from reduced oxygen extraction or impaired efficiency due to pronouncedly enhanced myocardial mass developed to excel in strenuous exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Verenpaineen kotimittaus − epidemiologia ja kliininen käyttö Kohonnutta verenpainetta, maailmanlaajuisesti merkittävintä ennenaikaiselle kuolemalle altistavaa riskitekijää, ei voida tunnistaa tai hoitaa ilman tarkkoja ja käytännöllisiä verenpaineen mittausmenetelmiä. Verenpaineen kotimittaus on saavuttanut suuren suosion potilaiden keskuudessa. Lääkärit eivät ole kuitenkaan vielä täysin hyväksyneet verenpaineen kotimittausta, sillä riittävä todistusaineisto sen toimivuudesta ja eduista on puuttunut. Tämän tutkimuksen tarkoituksena oli osoittaa, että kotona mitattu verenpaine (kotipaine) on perinteistä vastaanotolla mitattua verenpainetta (vastaanottopaine) tarkempi, ja että se on tehokas myös kliinisessä käytössä. Tutkimme kotipaineen käyttöä verenpainetaudin diagnosoinnissa ja hoidossa. Lisäksi tarkastelimme kotipaineen yhteyttä verenpainetaudin aiheuttamiin kohde-elinvaurioihin. Ensimmäinen aineisto, joka oli edustava otos Suomen aikuisväestöstä, koostui 2 120 45–74-vuotiaasta tutkimushenkilöstä. Tutkittavat mittasivat kotipainettaan viikon ajan ja osallistuivat terveystarkastukseen, johon sisältyi kliinisen tutkimuksen ja haastattelun lisäksi sydänfilmin otto ja vastaanottopaineen mittaus. 758 tutkittavalle suoritettiin lisäksi kaulavaltimon seinämän intima-mediakerroksen paksuuden (valtimonkovettumataudin mittari) mittaus ja 237:lle valtimon pulssiaallon nopeuden (valtimojäykkyyden mittari) mittaus. Toisessa aineistossa, joka koostui 98 verenpainetautia sairastavasta potilaasta, hoitoa ohjattiin satunnaistamisesta riippuen joko ambulatorisen eli vuorokausirekisteröinnillä mitatun verenpaineen tai kotipaineen perusteella. Vastaanottopaine oli kotipainetta merkittävästi korkeampi (systolisen/diastolisen paineen keskiarvoero oli 8/3 mmHg) ja yksimielisyys verenpainetaudin diagnoosissa kahden menetelmän välillä oli korkeintaan kohtalainen (75 %). 593 tutkittavasta, joilla oli kohonnut verenpaine vastaanotolla, 38 %:lla oli normaali verenpaine kotona eli ns. valkotakkiverenpaine. Verenpainetauti voidaan siis ylidiagnosoida joka kolmannella potilaalla seulontatilanteessa. Valkotakkiverenpaine oli yhteydessä lievästi kohonneeseen verenpaineeseen, matalaan painoindeksiin ja tupakoimattomuuteen, muttei psykiatriseen sairastavuuteen. Valkotakkiverenpaine ei kuitenkaan vaikuttaisi olevan täysin vaaraton ilmiö ja voi ennustaa tulevaa verenpainetautia, sillä siitä kärsivien sydän- ja verisuonitautien riskitekijäprofiili oli normaalipaineisten ja todellisten verenpainetautisten riskitekijäprofiilien välissä. Kotipaineella oli vastaanottopainetta vahvempi yhteys verenpainetaudin aiheuttamiin kohde-elinvaurioihin (intima-mediakerroksen paksuus, pulssiaallon nopeus ja sydänfilmistä todettu vasemman kammion suureneminen). Kotipaine oli tehokas verenpainetaudin hoidon ohjaaja, sillä kotipaineeseen ja ambulatoriseen paineeseen, jota on pidetty verenpainemittauksen ”kultaisena standardina”, perustuva lääkehoidon ohjaus johti yhtä hyvään verenpaineen hallintaan. Tämän ja aikaisempien tutkimusten tulosten pohjalta voidaan todeta, että verenpaineen kotimittaus on selkeä parannus perinteiseen vastaanotolla tapahtuvaan verenpainemittaukseen verrattuna. Verenpaineen kotimittaus on käytännöllinen, tarkka ja laajasti saatavilla oleva menetelmä, josta voi tulla jopa ensisijainen vaihtoehto verenpainetautia diagnosoitaessa ja hoitaessa. Verenpaineen mittauskäytäntöön tarvitaan muutos, sillä näyttöön perustuvan lääketieteen perusteella vaikuttaa, että vastaanotolla tapahtuvaa verenpainemittausta tulisi käyttää vain seulontatarkoitukseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood flow in human aorta is an unsteady and complex phenomenon. The complex patterns are related to the geometrical features like curvature, bends, and branching and pulsatile nature of flow from left ventricle of heart. The aim of this work was to understand the effect of aorta geometry on the flow dynamics. To achieve this, 3D realistic and idealized models of descending aorta were reconstructed from Computed Tomography (CT) images of a female patient. The geometries were reconstructed using medical image processing code. The blood flow in aorta was assumed to be laminar and incompressible and the blood was assumed to be Newtonian fluid. A time dependent pulsatile and parabolic boundary condition was deployed at inlet. Steady and unsteady blood flow simulations were performed in real and idealized geometries of descending aorta using a Finite Volume Method (FVM) code. Analysis of Wall Shear Stress (WSS) distribution, pressure distribution, and axial velocity profiles were carried out in both geometries at steady and unsteady state conditions. The results obtained in thesis work reveal that the idealization of geometry underestimates the values of WSS especially near the region with sudden change of diameter. However, the resultant pressure and velocity in idealized geometry are close to those in real geometry

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to simulate blood flow in thoracic human aorta and understand the role of flow dynamics in the initialization and localization of atherosclerotic plaque in human thoracic aorta. The blood flow dynamics in idealized and realistic models of human thoracic aorta were numerically simulated in three idealized and two realistic thoracic aorta models. The idealized models of thoracic aorta were reconstructed with measurements available from literature, and the realistic models of thoracic aorta were constructed by image processing Computed Tomographic (CT) images. The CT images were made available by South Karelia Central Hospital in Lappeenranta. The reconstruction of thoracic aorta consisted of operations, such as contrast adjustment, image segmentations, and 3D surface rendering. Additional design operations were performed to make the aorta model compatible for the numerical method based computer code. The image processing and design operations were performed with specialized medical image processing software. Pulsatile pressure and velocity boundary conditions were deployed as inlet boundary conditions. The blood flow was assumed homogeneous and incompressible. The blood was assumed to be a Newtonian fluid. The simulations with idealized models of thoracic aorta were carried out with Finite Element Method based computer code, while the simulations with realistic models of thoracic aorta were carried out with Finite Volume Method based computer code. Simulations were carried out for four cardiac cycles. The distribution of flow, pressure and Wall Shear Stress (WSS) observed during the fourth cardiac cycle were extensively analyzed. The aim of carrying out the simulations with idealized model was to get an estimate of flow dynamics in a realistic aorta model. The motive behind the choice of three aorta models with distinct features was to understand the dependence of flow dynamics on aorta anatomy. Highly disturbed and nonuniform distribution of velocity and WSS was observed in aortic arch, near brachiocephalic, left common artery, and left subclavian artery. On the other hand, the WSS profiles at the roots of branches show significant differences with geometry variation of aorta and branches. The comparison of instantaneous WSS profiles revealed that the model with straight branching arteries had relatively lower WSS compared to that in the aorta model with curved branches. In addition to this, significant differences were observed in the spatial and temporal profiles of WSS, flow, and pressure. The study with idealized model was extended to study blood flow in thoracic aorta under the effects of hypertension and hypotension. One of the idealized aorta models was modified along with the boundary conditions to mimic the thoracic aorta under the effects of hypertension and hypotension. The results of simulations with realistic models extracted from CT scans demonstrated more realistic flow dynamics than that in the idealized models. During systole, the velocity in ascending aorta was skewed towards the outer wall of aortic arch. The flow develops secondary flow patterns as it moves downstream towards aortic arch. Unlike idealized models, the distribution of flow was nonplanar and heavily guided by the artery anatomy. Flow cavitation was observed in the aorta model which was imaged giving longer branches. This could not be properly observed in the model with imaging containing a shorter length for aortic branches. The flow circulation was also observed in the inner wall of the aortic arch. However, during the diastole, the flow profiles were almost flat and regular due the acceleration of flow at the inlet. The flow profiles were weakly turbulent during the flow reversal. The complex flow patterns caused a non-uniform distribution of WSS. High WSS was distributed at the junction of branches and aortic arch. Low WSS was distributed at the proximal part of the junction, while intermedium WSS was distributed in the distal part of the junction. The pulsatile nature of the inflow caused oscillating WSS at the branch entry region and inner curvature of aortic arch. Based on the WSS distribution in the realistic model, one of the aorta models was altered to induce artificial atherosclerotic plaque at the branch entry region and inner curvature of aortic arch. Atherosclerotic plaque causing 50% blockage of lumen was introduced in brachiocephalic artery, common carotid artery, left subclavian artery, and aortic arch. The aim of this part of the study was first to study the effect of stenosis on flow and WSS distribution, understand the effect of shape of atherosclerotic plaque on flow and WSS distribution, and finally to investigate the effect of lumen blockage severity on flow and WSS distributions. The results revealed that the distribution of WSS is significantly affected by plaque with mere 50% stenosis. The asymmetric shape of stenosis causes higher WSS in branching arteries than in the cases with symmetric plaque. The flow dynamics within thoracic aorta models has been extensively studied and reported here. The effects of pressure and arterial anatomy on the flow dynamic were investigated. The distribution of complex flow and WSS is correlated with the localization of atherosclerosis. With the available results we can conclude that the thoracic aorta, with complex anatomy is the most vulnerable artery for the localization and development of atherosclerosis. The flow dynamics and arterial anatomy play a role in the localization of atherosclerosis. The patient specific image based models can be used to diagnose the locations in the aorta vulnerable to the development of arterial diseases such as atherosclerosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an increasing reliance on computers to solve complex engineering problems. This is because computers, in addition to supporting the development and implementation of adequate and clear models, can especially minimize the financial support required. The ability of computers to perform complex calculations at high speed has enabled the creation of highly complex systems to model real-world phenomena. The complexity of the fluid dynamics problem makes it difficult or impossible to solve equations of an object in a flow exactly. Approximate solutions can be obtained by construction and measurement of prototypes placed in a flow, or by use of a numerical simulation. Since usage of prototypes can be prohibitively time-consuming and expensive, many have turned to simulations to provide insight during the engineering process. In this case the simulation setup and parameters can be altered much more easily than one could with a real-world experiment. The objective of this research work is to develop numerical models for different suspensions (fiber suspensions, blood flow through microvessels and branching geometries, and magnetic fluids), and also fluid flow through porous media. The models will have merit as a scientific tool and will also have practical application in industries. Most of the numerical simulations were done by the commercial software, Fluent, and user defined functions were added to apply a multiscale method and magnetic field. The results from simulation of fiber suspension can elucidate the physics behind the break up of a fiber floc, opening the possibility for developing a meaningful numerical model of the fiber flow. The simulation of blood movement from an arteriole through a venule via a capillary showed that the model based on VOF can successfully predict the deformation and flow of RBCs in an arteriole. Furthermore, the result corresponds to the experimental observation illustrates that the RBC is deformed during the movement. The concluding remarks presented, provide a correct methodology and a mathematical and numerical framework for the simulation of blood flows in branching. Analysis of ferrofluids simulations indicate that the magnetic Soret effect can be even higher than the conventional one and its strength depends on the strength of magnetic field, confirmed experimentally by Völker and Odenbach. It was also shown that when a magnetic field is perpendicular to the temperature gradient, there will be additional increase in the heat transfer compared to the cases where the magnetic field is parallel to the temperature gradient. In addition, the statistical evaluation (Taguchi technique) on magnetic fluids showed that the temperature and initial concentration of the magnetic phase exert the maximum and minimum contribution to the thermodiffusion, respectively. In the simulation of flow through porous media, dimensionless pressure drop was studied at different Reynolds numbers, based on pore permeability and interstitial fluid velocity. The obtained results agreed well with the correlation of Macdonald et al. (1979) for the range of actual flow Reynolds studied. Furthermore, calculated results for the dispersion coefficients in the cylinder geometry were found to be in agreement with those of Seymour and Callaghan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alpha2-Adrenoceptors are cell-surface G protein coupled receptors that mediate many of the effects of the catecholamines noradrenaline and adrenaline. The three human α2-adrenoceptor subtypes are widely expressed in different tissues and organs, and they mediate many different physiological and pharmacological effects in the central and peripheral nervous system and as postsynaptic receptors in target organs. Previous studies have demonstrated that α2-adrenoceptors mediate both vascular constriction and dilatation in humans. Large inter-individual variation has been observed in the vascular responses to α2-adrenoceptor activation in clinical studies. All three receptor subtypes are potential drug targets. It was therefore considered important to further elucidate the details of adrenergic vascular regulation and its genetic variation, since such knowledge may help to improve the development of future cardiovascular drugs and intensive care therapies. Dexmedetomidine is the most selective and potent α2-adrenoceptor agonist currently available for clinical use. When given systemically, dexmedetomidine induces nearly complete sympatholysis already at low concentrations, and postsynaptic effects, such vasoconstriction, can be observed with increasing concentrations. Thus, local infusions of small doses of dexmedetomidine into dorsal hand veins and the application of pharmacological sympathectomy with brachial plexus block provide a means to assess drug-induced peripheral vascular responses without interference from systemic pharmacological effects and autonomic nervous system regulation. Dexmedetomidine was observed to have biphasic effects on haemodynamics, with an initial decrease in blood pressure at low concentrations followed by substantial increases in blood pressure and coronary vascular resistance at high concentrations. Plasma concentrations of dexmedetomidine that significantly exceeded the recommended therapeutic level did not reduce myocardial blood flow below the level that is observed with the usual therapeutic concentrations and did not induce any evident myocardial ischaemia in healthy subjects. Further, it was demonstrated that dexmedetomidine also had significant vasodilatory effects through activation of endothelial nitric oxide synthesis, and thus when the endothelial component of the blood vessel response to dexmedetomidine was inhibited, peripheral vasoconstriction was augmented. Hand vein constriction responses to α2-adrenoceptor activation by dexmedetomidine were only weakly associated with the constriction responses to α1-adrenoceptor activation, pointing to independent cellular regulation by these two adrenoceptor classes. Substantial inter-individual variation was noted in the venous constriction elicited by activation of α2-adrenoceptors by dexmedetomidine. In two study populations from two different continents, a single nucleotide polymorphism in the PRKCB gene was found to be associated with the dorsal hand vein constriction response to dexmedetomidine, suggesting that protein kinase C beta may have an important role in the vascular α2-adrenoceptor signalling pathways activated by dexmedetomidine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate the possibility to enhance certain qualities of facial prostheses. Polymethyl methacrylate is still being used as base mate¬rial or clip carrier material, but it is hard and heavy, and debonding of the silicone from the acrylic base material is a frequent problem. This thesis aims to evaluate the use of fiber-reinforced composite (FRC) as framework material for maxillofacial silicone prostheses. FRC has been used as reinforcement in removable and fixed partial dentures since the 1990s. This material is lightweight and can be fabricated to compress the margins of the prosthesis slightly, to keep it tightly against the skin during jaw movements and facial expressions. Additionally, the use of a thermochromic pigment, colorless in room temperature and red in a cold environment, was studied in order to evaluate the possibility of using this color changing pigment in facial prostheses to mimic the color change of facial skin in cold weather. The tensile bond strength between pre-impregnated, unidirectional FRC and maxillofacial silicone elastomer was studied. Three different bonding agents or primers were compared. Bond strength was improved by one of the primers and by roughening the surface. The effect of a skin compressing glass fiber-reinforced composite framework on facial skin blood flow was studied by using a face mask, constructed with a compression pad corresponding to the outer margin of a glass fiber-reinforced framework beam of a facial prosthesis. The skin blood flow of ten healthy volunteers, aged 23-25 years, was measured during touch, light, and moderate compression of the skin, by using laser Doppler imaging technique. None of the compressions showed any marked effects on local skin blood flow. There were no significant differences between blood flow during compression and at baseline. Maxillofacial silicone elastomer was colored intrinsically with conventional color pigments: a control group containing only conventional pigments was compared to two test groups with 0.2 wt% and 0.6 wt% thermochromic pigment added. The color of the material was measured with a spectrophotometer in room temperature and after storage in a freezer. The color stability of the maxillofacial silicone elastomer colored with thermo¬chromic pigment was evaluated by artificial aging. The color dif¬ference of the L* (lightness) and a* values (redness), comparing color after the samples were stored at room temperature and in a freezer (-19°C), was statistically significant for both 0.2 wt% and 0.6 wt% thermo¬chromic pigment groups. The differences in the b* values (yellowness) were statistically significant for the 0.6 wt% group. Exposure to ultraviolet (UV) radiation led to visually noticeable and statistically signifi¬cant color changes (ΔE) in all color values in both test groups. The specimens containing thermochromic pigment were very sensitive to UV radiation. In conclusion, a framework of fiber-reinforced composite can successfully be bonded to maxillofacial silicone elastomer, and a framework beam, compressing the facial skin, did not remarkably alter the skin blood flow on healthy, young adults. The thermochromic pigment showed color change in maxillofacial silicone elastomer. However, artificial aging showed that it was too sensitive to UV radiation to be used, as such, in maxillofacial prostheses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary artery disease is an atherosclerotic disease, which leads to narrowing of coronary arteries, deteriorated myocardial blood flow and myocardial ischaemia. In acute myocardial infarction, a prolonged period of myocardial ischaemia leads to myocardial necrosis. Necrotic myocardium is replaced with scar tissue. Myocardial infarction results in various changes in cardiac structure and function over time that results in “adverse remodelling”. This remodelling may result in a progressive worsening of cardiac function and development of chronic heart failure. In this thesis, we developed and validated three different large animal models of coronary artery disease, myocardial ischaemia and infarction for translational studies. In the first study the coronary artery disease model had both induced diabetes and hypercholesterolemia. In the second study myocardial ischaemia and infarction were caused by a surgical method and in the third study by catheterisation. For model characterisation, we used non-invasive positron emission tomography (PET) methods for measurement of myocardial perfusion, oxidative metabolism and glucose utilisation. Additionally, cardiac function was measured by echocardiography and computed tomography. To study the metabolic changes that occur during atherosclerosis, a hypercholesterolemic and diabetic model was used with [18F] fluorodeoxyglucose ([18F]FDG) PET-imaging technology. Coronary occlusion models were used to evaluate metabolic and structural changes in the heart and the cardioprotective effects of levosimendan during post-infarction cardiac remodelling. Large animal models were used in testing of novel radiopharmaceuticals for myocardial perfusion imaging. In the coronary artery disease model, we observed atherosclerotic lesions that were associated with focally increased [18F]FDG uptake. In heart failure models, chronic myocardial infarction led to the worsening of systolic function, cardiac remodelling and decreased efficiency of cardiac pumping function. Levosimendan therapy reduced post-infarction myocardial infarct size and improved cardiac function. The novel 68Ga-labeled radiopharmaceuticals tested in this study were not successful for the determination of myocardial blood flow. In conclusion, diabetes and hypercholesterolemia lead to the development of early phase atherosclerotic lesions. Coronary artery occlusion produced considerable myocardial ischaemia and later infarction following myocardial remodelling. The experimental models evaluated in these studies will enable further studies concerning disease mechanisms, new radiopharmaceuticals and interventions in coronary artery disease and heart failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new approach to the determination of the thermal parameters of high-power batteries is introduced here. Application of local heat flux measurement with a gradient heat flux sensor (GHFS) allows determination of the cell thermal parameters in di_erent surface points of the cell. The suggested methodology is not cell destructive as it does not require deep discharge of the cell or application of any charge/discharge cycles during measurements of the thermal parameters of the cell. The complete procedure is demonstrated on a high-power Li-ion pouch cell, and it is verified on a sample with well-known thermal parameters. A comparison of the experimental results with conventional thermal characterization methods shows an acceptably low error. The dependence of the cell thermal parameters on state of charge (SoC) and measurement points on the surface was studied by the proposed measurement approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Työn tavoitteena on Stora Enso Oyj:n Imatran tehtaiden energiaraportoinnin luotettavuuden parantaminen. Raportoinnissa esiintyvää tase-eroa lämmön tuotannon ja kulutuksen välillä on erilaisten selvitysten perusteella pyritty pienentämään. Höyryn ja lauhteen mittausten virheellisyyttä on tutkittu erilaisten osasto- ja höyrylinja- kohtaisten lämpötaseiden avulla. Taseiden lisäksi mittauksen oikeellisuutta selvitettäessä on käytetty tunnuslukuina lämmön ominaiskulutuksia, joita on verrattu Suomen metsäteollisuuden keskimääräisiin arvoihin. Työssä on tarkistettu myös raportointijärjestelmän laskenta ja päivitetty tarvittavat muutokset. Osa raportoinnin tase-erosta johtuu höyryn virtausmittauksen epävarmuudesta. Tässä työssä on esitetty erilaisia vaihtoehtoja sille, mistä mittauksen epävarmuus johtuu. Samalla on selvitetty virtausmittauksen periaatetta ja siihen tarvittavaa laitteistoa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tässä diplomityössä suunniteltiin ja rakennettiin kaasuturbiinin kaasusuuttimien virtausmittauslaitteisto. Suuttimien epätasainen toiminta kasvattaa kaasuturbiinin poistolämpötilahajontaa. Virtausmittauksien perusteella voidaan määrittää suuttimien efektiivinen virtauspoikkipinta-ala. Suuttimien asennusjärjestys opti-moidaan suuttimien välisten pinta-alaerojen mukaisesti, jolloin polttoainevirtaus polttokammioihin on mahdollisimman tasainen ja poistolämpötilahajonta pienenee. Kaasuturbiinin MS6001 esittelyssä keskityttiin tärkeimpiin komponentteihin sekä polttoainesuuttimien testauksen kannalta oleellisiin osiin ja niiden toimintaan. Teoriaosuudessa tarkasteltiin tilavuusvirran sekä suutinvirtauksen laskennassa käytettäviä yhtälöitä. Mittalaitteiston suunnittelu ja toteutus olivat tämän työn laajin osa-alue. Laitteiston keskeiset osat ovat kuristuselin ja suutintestausosa. Kuristuselintyypiksi valittiin rengaskammiollinen kuristuslaippa, joka suun-niteltiin standardin SFS-EN ISO 5167:2003 mukaisesti. Standardissa annettujen yhtälöiden antamia tuloksia verrattiin numeerisella virtauslaskentamallilla lasket-tuihin tuloksiin. Suutinrunkojen ja -kärkien mittauksien suunnittelussa sovellettiin samaa standardia sekä numeerista virtauslaskentaa optimaalisen sijainnin löytämiseksi paineyhteelle. Mittauksissa syntyvien epävarmuuksien arviointiin kiinnitettiin erityistä huomiota. Kokeellisessa osuudessa mitattiin yhden kunnostetun suuttimen, käytetyn suut-timen ja suutinrungon virtausta. Tuloksien perusteella laskettiin efektiiviset pinta-alat, joita verrattiin turbiinivalmistajan ilmoittamiin pinta-aloihin. Lopuksi arvioitiin mittaustulosten perusteella laitteiston toimivuutta. Virhe-arvioinnin ja mittaustulosten perusteella laadittiin teknisiä parannusehdotuksia suutintestauslaitteiston luotettavan toiminnan varmistamiseksi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The transport of macromolecules, such as low-density lipoprotein (LDL), and their accumulation in the layers of the arterial wall play a critical role in the creation and development of atherosclerosis. Atherosclerosis is a disease of large arteries e.g., the aorta, coronary, carotid, and other proximal arteries that involves a distinctive accumulation of LDL and other lipid-bearing materials in the arterial wall. Over time, plaque hardens and narrows the arteries. The flow of oxygen-rich blood to organs and other parts of the body is reduced. This can lead to serious problems, including heart attack, stroke, or even death. It has been proven that the accumulation of macromolecules in the arterial wall depends not only on the ease with which materials enter the wall, but also on the hindrance to the passage of materials out of the wall posed by underlying layers. Therefore, attention was drawn to the fact that the wall structure of large arteries is different than other vessels which are disease-resistant. Atherosclerosis tends to be localized in regions of curvature and branching in arteries where fluid shear stress (shear rate) and other fluid mechanical characteristics deviate from their normal spatial and temporal distribution patterns in straight vessels. On the other hand, the smooth muscle cells (SMCs) residing in the media layer of the arterial wall respond to mechanical stimuli, such as shear stress. Shear stress may affect SMC proliferation and migration from the media layer to intima. This occurs in atherosclerosis and intimal hyperplasia. The study of blood flow and other body fluids and of heat transport through the arterial wall is one of the advanced applications of porous media in recent years. The arterial wall may be modeled in both macroscopic (as a continuous porous medium) and microscopic scales (as a heterogeneous porous medium). In the present study, the governing equations of mass, heat and momentum transport have been solved for different species and interstitial fluid within the arterial wall by means of computational fluid dynamics (CFD). Simulation models are based on the finite element (FE) and finite volume (FV) methods. The wall structure has been modeled by assuming the wall layers as porous media with different properties. In order to study the heat transport through human tissues, the simulations have been carried out for a non-homogeneous model of porous media. The tissue is composed of blood vessels, cells, and an interstitium. The interstitium consists of interstitial fluid and extracellular fibers. Numerical simulations are performed in a two-dimensional (2D) model to realize the effect of the shape and configuration of the discrete phase on the convective and conductive features of heat transfer, e.g. the interstitium of biological tissues. On the other hand, the governing equations of momentum and mass transport have been solved in the heterogeneous porous media model of the media layer, which has a major role in the transport and accumulation of solutes across the arterial wall. The transport of Adenosine 5´-triphosphate (ATP) is simulated across the media layer as a benchmark to observe how SMCs affect on the species mass transport. In addition, the transport of interstitial fluid has been simulated while the deformation of the media layer (due to high blood pressure) and its constituents such as SMCs are also involved in the model. In this context, the effect of pressure variation on shear stress is investigated over SMCs induced by the interstitial flow both in 2D and three-dimensional (3D) geometries for the media layer. The influence of hypertension (high pressure) on the transport of lowdensity lipoprotein (LDL) through deformable arterial wall layers is also studied. This is due to the pressure-driven convective flow across the arterial wall. The intima and media layers are assumed as homogeneous porous media. The results of the present study reveal that ATP concentration over the surface of SMCs and within the bulk of the media layer is significantly dependent on the distribution of cells. Moreover, the shear stress magnitude and distribution over the SMC surface are affected by transmural pressure and the deformation of the media layer of the aorta wall. This work reflects the fact that the second or even subsequent layers of SMCs may bear shear stresses of the same order of magnitude as the first layer does if cells are arranged in an arbitrary manner. This study has brought new insights into the simulation of the arterial wall, as the previous simplifications have been ignored. The configurations of SMCs used here with elliptic cross sections of SMCs closely resemble the physiological conditions of cells. Moreover, the deformation of SMCs with high transmural pressure which follows the media layer compaction has been studied for the first time. On the other hand, results demonstrate that LDL concentration through the intima and media layers changes significantly as wall layers compress with transmural pressure. It was also noticed that the fraction of leaky junctions across the endothelial cells and the area fraction of fenestral pores over the internal elastic lamina affect the LDL distribution dramatically through the thoracic aorta wall. The simulation techniques introduced in this work can also trigger new ideas for simulating porous media involved in any biomedical, biomechanical, chemical, and environmental engineering applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL, OMIM #125310) is an inherited vascular disease. The main symptoms include migraineous headache, recurrent strokes and progressive cognitive impairment. CADASIL is caused by mutations in the NOTCH3 gene which result in degeneration of vascular smooth muscle cells, arteriolar stenosis and impaired cerebral blood flow. The aims of this study were assessment of the genetic background of Finnish and Swedish CADASIL patients, analysis of genetic and environmental factors that may influence the phenotype, and identification of the optimal diagnostic strategy. The majority of Finnish CADASIL patients carry the p.Arg133Cys mutation. Haplotype analysis of 18 families revealed a region of linkage disequilibrium around the NOTCH3 locus, which is evidence for a founder effect and a common ancestral mutation. Despite the same mutational background, the clinical course of CADASIL is highly variable between and even within families. The association of several genetic factors with the phenotypic variation was investigated in 120 CADASIL patients. Apolipoprotein E allele 4 was associated with earlier occurrence of strokes, especially in younger patients. Study of a pair of monozygotic twins with CADASIL revealed environmental factors which may influence the phenotype, i.e. smoking, statin medication and physical activity. Knowledge of these factors is useful, since life-style choices may influence the disease progression. The clinical CADASIL diagnosis can be confirmed by detection of either the NOTCH3 mutation or granular osmiophilic material by electron microscopy in skin biopsy, although the sensitivity estimates have been contradictory. Comparison of these two methods in a group of 131 diagnostic cases from Finland, Sweden and France demonstrated that both methods are highly sensitive and reliable.