69 resultados para Spring Mill
Resumo:
Main objective of this research was to find suitable polymeric ultrafiltration membranes with high retentions, good capacities and low fouling tendencies for the E2- and EP-effluent ultrafiltration. Purpose was to treat alkaline bleaching effluents with ultrafiltration in a way that permeates of the filtrations could be recycled back to process and the consumption of fresh water in the pulp mill could be reduced significantly. In the theoretical part of this work the challenges set by the pulp and paper indus-try processes for membranes were examined. An overview of the membrane tech-nology in the pulp industry was also provided. In addition process conditions in the chemical pulp bleaching and properties of bleaching effluents were discussed in literature study. In experimental part the E2- and EP-stage bleaching effluents from Stora Enso Imatra kraft pulp mill were ultrafiltered with CR250- and CR200-filters. Suitable membranes for ultrafiltration were chosen after screening experiments. Concentra-tion experiment was made for the E2-effluent in order to estimate water saving potential. The E2-effluent was finally ultrafiltered in the pulp mill in order to test the feasibility of ultrafiltration in a real industrial environment. Good membrane for the EP-effluent ultrafiltration based on the EP-screening ex-periments was polyethersulfone membrane UP020 with cut-off value of 20 000 Da. Polysulfone membrane UFX05 with cut-off value of 5 000 Da was promising membrane for the ultrafiltration of the E2-effluent. Based on the concentration filtration of the E2-effluent with UFX05 membrane the water saving potential could be 2.2 m3/Adt for the industrial scale ultrafiltration process. Retention re-sults, such as average COD retention of 60 %, from the trial filtration at the pulp mill with UFX05 membrane were modest compared to the screening experiments, where average COD retention was 75 %. Therefore tighter ultrafiltration mem-branes should be tested for the ultrafiltration of the E2-effluent. The UP020 mem-brane seemed to be suitable for the ultrafiltration of the EP-effluent however con-centration and pilot scale ultrafiltration experiments are needed to verify this.
Resumo:
14 x 23 cm
Resumo:
Tämän työn tavoitteena on antaa kuvaus riskinhallintamenetelmistä viidelle välituotekemikaalille, joita käytetään Stora Enson Imatran tehtailla. Välituotekemikaalit ovat mustalipeä, viherlipeä, valkolipeä, natriumbisulfiitti ja natriumsulfiitti. Nämä kemikaalit ovat jo rekisteröityjä ECHA:an ja rekisteröintiin liittyen ECHA:an on toimitettava myös kuvaus riskinhallintamenetelmistä. Työn alussa kuvaillaan työn kannalta olennaiset säädökset ja viranomaiset, jotka valvovat kemikaalien käyttöä ja valmistusta Euroopan Unionin alueella. Tämän jälkeen kerrotaan yleisesti välituotekemikaalien rekisteröintikriteereistä. Työn loppuosa käsittää kuvauksen riskinhallintamenetelmistä jokaiselle kemikaalille. Riskinhallintamenetelmät sisältävät eristyksen teknisin keinoin, menettelytapa- ja valvontatekniikat, johtamistavat ja henkilökunnan koulutuksen ja välituotekemikaalien kuljetuksen. Myös jokaisen kemikaalin ominaisuudet on kuvattu ja lyhyt prosessikuvaus kemikaalien valmistuksesta ja käytöstä on esitetty helpottamaan ymmärtämistä.
Resumo:
Interest in water treatment by electrochemical methods has grown in recent years. Electrochemical oxidation has been applied particularly successfully to degrade different organic pollutants and disinfect drinking water. This study summarizes the effectiveness of the electrochemical oxidation technique in inactivating different primary biofilm forming paper mill bacteria as well as sulphide and organic material in pulp and paper mill wastewater in laboratory scale batch experiments. Three different electrodes, borondoped diamond (BDD), mixed metal oxide (MMO) and PbO2, were employed as anodes. The impact on inactivation efficiency of parameters such as current density and initial pH or chloride concentration of synthetic paper machine water was studied. The electrochemical behaviour of the electrodes was investigated by cyclic voltammetry with MMO, BDD and PbO2 electrodes in synthetic paper mill water as also with MMO and stainless steel electrodes with biocides. Some suggestions on the formation of different oxidants and oxidation mechanisms were also presented during the treatment. Aerobic paper mill bacteria species (Deinococcus geothermalis, Pseudoxanthomonas taiwanensis and Meiothermus silvanus) were inactivated effectively (>2 log) at MMO electrodes by current density of 50 mA/cm2 and the time taken three minutes. Increasing current density and initial chloride concentration of paper mill water increased the inactivation rate of Deinococcus geothermalis. The inactivation order of different bacteria species was Meiothermus silvanus > Pseudoxanthomonas taiwanensis > Deinococcus geothermalis. It was observed that inactivation was mainly due to the electrochemically generated chlorine/hypochlorite from chloride present in the water and also residual disinfection by chlorine/hypochlorite occurred. In real paper mill effluent treatment sulphide oxidation was effective with all the different initial concentrations (almost 100% reduction, current density 42.9 mA/cm2) and also anaerobic bacteria inactivation was observed (almost 90% reduction by chloride concentration of 164 mg/L and current density of 42.9 mA/cm2 in five minutes). Organic material removal was not as effective when comparing with other tested techniques, probably due to the relatively low treatment times. Cyclic voltammograms in synthetic paper mill water with stainless steel electrode showed that H2O2 could be degraded to radicals during the cathodic runs. This emphasises strong potential of combined electrochemical treatment with this biocide in bacteria inactivation in paper mill environments.
Resumo:
The efficient use of materials and natural recourses, for ecological and economic reasons, has become more and more important in all industries. In the forest industries this means higher levels of closure in the material circulations of the mills. One possibility to reduce wastewater discharge is to re-use part of the 2nd clarifier effluent as process water. The main target of this thesis was to evaluate the technical suitability of several mechanical and chemical tertiary treatment methods for water re-use. Some of the tested methods seemed to have high potential for the removal of some specific constituents from the wastewater. Tertiary treatment is needed because higher levels of closure may cause problems with increasing amounts of non-process elements in different points of kraft pulp process. The aspect of sustainable development was taken into account by evaluating positive and negative environmental effects of the treatment processes. Environmental benefits can be gained by using some of the tertiary treatment methods tested. These methods should still be researched more for system optimization.
Resumo:
This Master’s Thesis studies performance management system and its benefits, risks and costs. Objective of the thesis is to describe and evaluate currently used supply chain performance management system (SCPMS) in a Finnish paper mill and its interfaces with its business unit’s SCPMS. As a result, the host company has improvement road map for improving its SCPMS. Used SCPMS in the host company and its interfaces to business unit’s SCPMS are described based on interviews held in the host company and the business unit. Evaluation of the host company’s SCPMS is based on literature study. For improvement road map, three areas in need of improvements are chosen. The study shows the need of high level top management commitment in successful performance management system implementation and usage, especially when the system is deployed to lower levels in the organization.
Resumo:
The objective of this project was to introduce a new software product to pulp industry, a new market for case company. An optimization based scheduling tool has been developed to allow pulp operations to better control their production processes and improve both production efficiency and stability. Both the work here and earlier research indicates that there is a potential for savings around 1-5%. All the supporting data is available today coming from distributed control systems, data historians and other existing sources. The pulp mill model together with the scheduler, allows what-if analyses of the impacts and timely feasibility of various external actions such as planned maintenance of any particular mill operation. The visibility gained from the model proves also to be a real benefit. The aim is to satisfy demand and gain extra profit, while achieving the required customer service level. Research effort has been put both in understanding the minimum features needed to satisfy the scheduling requirements in the industry and the overall existence of the market. A qualitative study was constructed to both identify competitive situation and the requirements vs. gaps on the market. It becomes clear that there is no such system on the marketplace today and also that there is room to improve target market overall process efficiency through such planning tool. This thesis also provides better overall understanding of the different processes in this particular industry for the case company.
Resumo:
The aim of this thesis is to define effects of lignin separation process on Pulp mill chemical balance especially on sodium/sulphur-balance. The objective is to develop a simulation model with WinGEMS Process Simulator and use that model to simulate the chemical balances and process changes. The literature part explains what lignin is and how kraft pulp is produced. It also introduces to the methods that can be used to extract lignin from black liquor stream and how those methods affect the pulping process. In experimental part seven different cases are simulated with the created simulation model. The simulations are based on selected reference mill that produces 500 000 tons of bleached air-dried (90 %) pulp per year. The simulations include the chemical balance calculation and the estimated production increase. Based on the simulations the heat load of the recovery boiler can be reduced and the pulp production increased when lignin is extracted. The simulations showed that decreasing the waste acid stream intake from the chlorine dioxide plant is an effective method to control the sulphidity level when about 10 % of lignin is extracted. With higher lignin removal rates the in-mill sulphuric acid production has been discovered to be a better alternative to the sulphidity control.