54 resultados para Thermal modeling
Resumo:
Over the last decades, calibration techniques have been widely used to improve the accuracy of robots and machine tools since they only involve software modification instead of changing the design and manufacture of the hardware. Traditionally, there are four steps are required for a calibration, i.e. error modeling, measurement, parameter identification and compensation. The objective of this thesis is to propose a method for the kinematics analysis and error modeling of a newly developed hybrid redundant robot IWR (Intersector Welding Robot), which possesses ten degrees of freedom (DOF) where 6-DOF in parallel and additional 4-DOF in serial. In this article, the problem of kinematics modeling and error modeling of the proposed IWR robot are discussed. Based on the vector arithmetic method, the kinematics model and the sensitivity model of the end-effector subject to the structure parameters is derived and analyzed. The relations between the pose (position and orientation) accuracy and manufacturing tolerances, actuation errors, and connection errors are formulated. Computer simulation is performed to examine the validity and effectiveness of the proposed method.
Resumo:
The goal of this thesis is to implement software for creating 3D models from point clouds. Point clouds are acquired with stereo cameras, monocular systems or laser scanners. The created 3D models are triangular models or NURBS (Non-Uniform Rational B-Splines) models. Triangular models are constructed from selected areas from the point clouds and resulted triangular models are translated into a set of quads. The quads are further translated into an estimated grid structure and used for NURBS surface approximation. Finally, we have a set of NURBS surfaces which represent the whole model. The problem wasn’t so easy to solve. The selected triangular surface reconstruction algorithm did not deal well with noise in point clouds. To handle this problem, a clustering method is introduced for simplificating the model and removing noise. As we had better results with the smaller point clouds produced by clustering, we used points in clusters to better estimate the grids for NURBS models. The overall results were good when the point cloud did not have much noise. The point clouds with small amount of error had good results as the triangular model was solid. NURBS surface reconstruction performed well on solid models.
Resumo:
Neste Oil has introduced plant oils and animal fats for the production of NExBTL renewable diesel, and these raw materials differ from the conventional mineral based oils. One subject of new raw materials study is thermal degradation, or in another name pyrolysis, of these organic oils and fats. The aim of this master’s thesis is to increase knowledge on thermal degradation of these new raw materials, and to identify possible gaseous harmful thermal degradation compounds. Another aim is to de-termine the health and environmental hazards of identified compounds. One objective is also to examine the formation possibilities of hazardous compounds in the produc-tion of NExBTL-diesel. Plant oils and animal fats consist mostly of triglycerides. Pyrolysis of triglycerides is a complex phenomenon, and many degradation products can be formed. Based on the literature studies, 13 hazardous degradation products were identified, one of which was acrolein. This compound is very toxic and dangerous to the environment. Own pyrolysis experiments were carried out with rapeseed and palm oils, and with a mix-ture of palm oil and animal fat. At least 12 hazardous compounds, including acrolein, were analysed from the gas phase. According to the experiments, the factors which influence on acrolein formation are the time of the experiment, the sphere (air/hydrogen) in which the experiment is carried out, and the characteristics of the used oil. The production of NExBTL-diesel is not based on pyrolysis. This is why thermal degradation is possible only when abnormal process conditions prevail.
Resumo:
This thesis includes several thermal hydraulic analyses related to the Loviisa WER 440 nuclear power plant units. The work consists of experimental studies, analysis of the experiments, analysis of some plant transits and development of a calculational model for calculation of boric acid concentrations in the reactor. In the first part of the thesis, in the case of won of boric acid solution behaviour during long term cooling period of LOCAs, experiments were performed in scaled down test facilities. The experimental data together with the results of RELAPS/MOD3 simulations were used to develop a model for calculations of boric acid concentrations in the reactor during LOCAs. The results of calculations showed that margins to critical concentrations that would lead to boric acid crystallization were large, both in the reactor core and in the lower plenum. This was mainly caused by the fact that water in the primary cooling circuit includes borax (Na)BsO,.IOHZO), which enters the reactor when ECC water is taken from the sump and greatly increases boric acid solubility in water. In the second part, in the case of simulation of horizontal steam generators, experiments were performed with PACTEL integral test loop to simulate loss of feedwater transients. The PACTEL experiments, as well as earlier REWET III natural circulation tests, were analyzed with RELAPS/MOD3 Version Sm5 code. The analysis showed that the code was capable of simulating the main events during the experiments. However, in the case of loss of secondary side feedwater the code was not completely capable to simulate steam superheating in the secondary side of the steam generators. The third part of the work consists of simulations of Loviisa VVER reactor pump trip transients with RELAPSlMODI Eur, RELAPS/MOD3 and CATHARE codes. All three codes were capable to simulate the two selected pump trip transients and no significant differences were found between the results of different codes. Comparison of the calculated results with the data measured in the Loviisa plant also showed good agreement.
Resumo:
The aim of this thesis is to investigate the thermal loading of medium voltage three-level NPC inverter’s semiconductor IGCT switches in different operation points. The objective is to reach both a fairly accurate off-line simulation program and also so simple a simulation model that its implementation into an embedded system could be reasonable in practice and a real time use should become feasible. Active loading limitation of the inverter can be realized with a thermal model which is practical in a real time use. Determining of the component heating has been divided into two parts; defining of component losses and establishing the structure of a thermal network. Basics of both parts are clarified. The simulation environment is Matlab-Simulink. Two different models are constructed – a more accurate one and a simplified one. Potential simplifications are clarified with the help of the first one. Simplifications are included in the latter model and the functionalities of both models are compared. When increasing the calculation time step a decreased number of considered components and time constants of the thermal network can be used in the simplified model. Heating of a switching component is dependent on its topological position and inverter’s operation point. The output frequency of the converter defines mainly which one of the switching components is – because of its losses and heating – the performance limiting component of the converter. Comparison of results given by different thermal models demonstrates that with larger time steps, describing of fast occurring switching losses becomes difficult. Generally articles and papers dealing with this subject are written for two-level inverters. Also inverters which apply direct torque control (DTC) are investigated rarely from the heating point of view. Hence, this thesis completes the former material.
Resumo:
A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:
Resumo:
The aim of the thesis is to design a suitable thermal model that can be used as a tool for constructing the TEFC squirrel cage induction machine in addition to the electromagnetic model. A lumped-parameter thermal model is developed. The related problems and aspects of implementation are discussed in details. Losses are calculated analytically and the loss values are used in the thermal model. The sensitivity analysis is introduced to determine the most critical parameters of the model.