Resumo |
The aim of the thesis is to design a suitable thermal model that can be used as a tool for constructing the TEFC squirrel cage induction machine in addition to the electromagnetic model. A lumped-parameter thermal model is developed. The related problems and aspects of implementation are discussed in details. Losses are calculated analytically and the loss values are used in the thermal model. The sensitivity analysis is introduced to determine the most critical parameters of the model. |
Identificador |
http://www.doria.fi/handle/10024/63035 URN:NBN:fi-fe201006091991 |
Idioma(s) |
en |
Palavras-Chave | #Totally Enclosed Fan Cooled (TEFC) induction machine #lumped-parameter thermal model #Thermal analysis |