150 resultados para BFB-boiler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The made research is focused on possibility of application of non ferrous metals in boiler pressure parts as a substitute of currently used ferrous-base alloys. The main issue was to define resistive ability of some perspective non ferrous metals to chlorine induced corrosion. Experimental study was performed using simultaneous thermal analysis (STA) in the temperature range of 400-700 °C. The chloride induced corrosion was simulated by mixtures of metal samples with potassium chloride treated by synthetic air. The advantage of synergetic effect of non ferrous alloys compare to single metals is shown due to the obtained data from conducted thermal balance tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä selvitetään kiertolaskennan periaatteita kuplapetikattilassa, esitetään lyhyesti kattilan toimintaperiaate ja paneudutaan alan laskentaohjelmistoihin. Luonnonkierto kattilan vesihöyrypiirissä on seurausta hydrostaattisesta paineesta, joka aiheutuu tiheyserosta nousu- ja laskuputkien välillä. Kiertolaskennassa on huomioitava kaksifaasivirtauksen ominaispiirteet. Höyry ja neste virtaavat putkistossa eri nopeuksilla, jolloin esimerkiksi painehäviön määrityksessä käytetään erilaisia korrelaatioita ja käyrästöjä. Kaksifaasivirtauksen laskennassa tarvitaan kolmea eri taseyhtälöä: energiatasetta, massatasetta ja liikemäärätasetta. Luonnonkiertokattiloissa höyrykierron suunnittelussa on kaksi pääasiallista ehtoa. Ensimmäiseksi tulee varmistaa riittävä kiertoveden massavirta, jotta vältetään höyrystinputkien puhki palaminen. Toiseksi tulee välttää höyrystinputken pinnan lämpötilavaihteluita ja värähtelyitä. Alustavassa luonnonkierron mitoituksessa turvaudutaan kokemusperäiseen tietoon. Myöhemmässä tarkemmassa mitoituksessa käytettäviä ohjelmistoja ovat NOWA sekä kaupalliset PPSD ja Apros. Laskenta lähtee liikkeelle siitä, että lasketaan ensin vesihöyrykierron massavirrat erilaisilla lämpökuormilla ja höyryntuotanto määritellään painehäviöiden perusteella. NOWA- ja PPSD- ohjelmistoilla tehtyjen esimerkkilaskelmien perusteella voidaan sanoa, että tulokset riippuvat käytetystä laskentamallista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxy-fuel combustion in a circulating fluidized bed (CFB) boiler appears to be a promising option for capturing CO2 in power plants. Oxy-fuel combustion is based on burning of fuel in the mixture of oxygen and re-circulated flue gas instead of air. Limestone (CaCO3) is typically used for capturing of SO2 in CFB boilers where limestone calcines to calcium oxide (CaO). Because of high CO2 concentration in oxy-fuel combustion, calcination reaction may be hindered or carbonation, the reverse reaction of calcination, may occur. Carbonation of CaO particles can cause problems especially in the circulation loop of a CFB boiler where temperature level is lower than in the furnace. The aim of the thesis was to examine carbonation of CaO in a fluidized bed heat exchanger of a CFB boiler featuring oxy-fuel combustion. The calculations and analyzing were based on measurement data from an oxy-fuel pilot plant and on 0-dimensional (0D) gas balance of a fluidized bed heat exchanger. Additionally, the objective was to develop a 1-dimensional (1D) model of a fluidized bed heat exchanger by searching a suitable pre-exponential factor for a carbonation rate constant. On the basis of gas measurement data and the 0D gas balance, it was found that the amount of fluidization gas decreased as it flew through the fluidized bed heat exchanger. Most likely the reason for this was carbonation of CaO. It was discovered that temperature has a promoting effect on the reaction rate of carbonation. With the 1D model, a suitable pre-exponential factor for the equation of carbonation rate constant was found. However, during measurements there were several uncertainties, and in the calculations plenty of assumptions were made. Besides, the temperature level in the fluidized bed heat exchanger was relatively low during the measurements. Carbonation should be considered when fluidized bed heat exchangers and the capacity of related fans are designed for a CFB boiler with oxy-fuel combustion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work is mainly focused on the technology of bubbling fluidized bed combustion. Heat transfer and hydrodynamics of the process were examined in the work in detail. Special emphasis was placed on the process of heat exchange in a freeboard zone of bubbling fluidized bed boiler. Operating mode of bubbling fluidized bed boiler depends on many parameters. To assess the influence of some parameters on a temperature regime inside the furnace a simplified method of zonal modeling was used in the work. Thus, effects of bed material fineness, excess air ratio and changes in boiler load were studied. Besides the technology of combustion in bubbling fluidized bed, other common technologies of solid fuels combustion were reviewed. In addition, brief survey of most widely used types of solid fuel was performed in the work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Remote monitoring of a power boiler allows the supplying company to make sure that equipment is used as supposed to and gives a good chance for process optimization. This improves co-operation between the supplier and the customer and creates an aura of trust that helps securing future contracts. Remote monitoring is already in use with recovery boilers but the goal is to expand especially to biomass-fired BFB-boilers. To make remote monitoring possible, data has to be measured reliably on site and the link between the power plant and supplying company’s server has to work reliably. Data can be gathered either with the supplier’s sensors or with measurements originally installed in the power plant if the plant in question is not originally built by the supplying company. Main goal in remote monitoring is process optimization and avoiding unnecessary accidents. This can be achieved for instance by following the efficiency curves and fouling in different parts of the process and comparing them to past values. The final amount of calculations depends on the amount of data gathered. Sudden changes in efficiency or fouling require further notice and in such a case it’s important that dialogue toward the power plant in question also works.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alfa Laval Aalborg Oy designs and manufactures waste heat recovery systems utilizing extended surfaces. The waste heat recovery boiler considered in this thesis is a water-tube boiler where exhaust gas is used as the convective heat transfer medium and water or steam flowing inside the tubes is subject to cross-flow. This thesis aims to contribute to the design of waste heat recovery boiler unit by developing a numerical model of the H-type finned tube bundle currently used by Alfa Laval Aalborg Oy to evaluate the gas-side heat transfer performance. The main objective is to identify weaknesses and potential areas of development in the current H-type finned tube design. In addition, numerical simulations for a total of 15 cases with varying geometric parameters are conducted to investigate the heat transfer and pressure drop performance dependent on H-type fin geometry. The investigated geometric parameters include fin width and height, fin spacing, and fin thickness. Comparison between single and double tube type configuration is also conducted. Based on the simulation results, the local heat transfer and flow behaviour of the H-type finned tube is presented including boundary layer development between the fins, the formation of recirculation zone behind the tubes, and the local variations of flow velocity and temperature within the tube bundle and on the fin surface. Moreover, an evaluation of the effects of various fin parameters on heat transfer and pressure drop performance of H-type finned tube bundle has been provided. It was concluded that from the studied parameters fin spacing and fin width had the most significant effect on tube bundle performance and the effect of fin thickness was the least important. Furthermore, the results suggested that the heat transfer performance would increase due to enhanced turbulence if the current double tube configuration is replaced with single tube configuration, but further investigation and experimental measurements are required in order to validate the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to find and analyze different methods which reduce fluid bed boilers’ auxiliary power consumption. The objective is to examine the effects and feasibility of these methods. The literature part explains how fluid bed boilers work and what are the main sources of auxiliary power consumption. Designs and operation of these equipment are presented. The literature part also discusses the basics of auxiliary power consumption reduction and introduces four low pressure drop constructions. The experimental part inspects six different methods. Effects of these methods on the auxiliary power consumption are calculated and their impacts on the operation of the boiler are modeled. Calculations show that reasonable changes can reduce fluid bed boiler’s auxiliary power consumption by 2,1-10,2 %. Biggest reductions come from lower air coefficients, smaller bed a-level pressures and lower primary/secondary air –ratios. Models showed no problems with the smaller bed a-level pressures. With the lower air coefficients and smaller primary/secondary air –ratios the models showed a significant increase in the carbon monoxide levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy generation industry is very capital-intensive industry. Productivity and availability requirements have increased while competition and quality requirement have increased. Maintenance has a significant role that these requirements can be reached. Even maintenance is much more than repairing faults nowadays, spare parts are important part of maintenance. Large power boilers are user-specific therefore features of boilers vary from project to project. Equipment have been designed to follow the customer’s requirements therefore spare parts are mainly user-specific also. The study starts with literature review introducing maintenance, failure mechanisms, and systems and equipment of bubbling fluidized bed boiler. At the final part spare part management is discussed from boiler technology point of view. For this part of the study science publications about spare part management are utilized also some specialist from a boiler technology company and other original equipment manufacturers were interviewed. Spare part management is challenging from the boiler supplier point of view and the end user of spare parts has a responsibility of stocking items. Criticality analysis can be used for finding most critical devices of the process and spare part management shall focus to those items. Spare parts are part of risk management. Stocking spare parts is increasing costs but then high spare part availability is decreasing delay time caused by fault of item.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compared to the use of traditional fossil fuels (coal, oil, natural gas), combustion of biomass and waste fuels has several environmental and economic advantages for heat and power generation. However, biomass and waste fuels might contain halogens (Cl, Br, F), alkali metals (Na, K) and heavy metals (Zn, Pb), which may cause harmful emissions and corrosion problems. Hightemperature corrosion occurs typically on furnace waterwalls and superheaters. The corrosion of the boiler tube materials limits the increase of thermal efficiency of steam boilers and leads to costly shutdowns and repairs. In recent years, some concerns have been raised about halogen (Cl, Br, and F)-related hightemperature corrosion in biomass- and waste-fired boilers. Chlorine-related high-temperature corrosion has been studied extensively. The presence of alkali chlorides in the deposits is believed to play a major role in the corrosion observed in biomass and waste fired boilers. However, there is much less information found in literature on the corrosion effect of bromine and fluorine. According to the literature, bromine is only assumed to play a role similar to chlorine; the role of fluorine is even less understood. In this work, a series of bubbling fluidized bed (BFB) bench-scale tests were carried out to characterize the formation and sulfation behaviors of KCl and KBr in BFB combustion conditions. Furthermore, a series of laboratory tests were carried out to investigate the hightemperature corrosion behaviors of three different superheater steels (10CrMo9-10, AISI 347 and Sanicro 28) exposed to potassium halides in ambient air and wet air (containing 30% H2O). The influence of H2O and O2 on the high-temperature corrosion of steels both with and without a salt (KCl) in three gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2) was also studied. From the bench-scale BFB combustion tests, it was found that HBr has a clearly higher affinity for the available K forming KBr than HCl forming KCl. The tests also indicated that KCl has a higher tendency for sulfation than KBr. From the laboratory corrosion tests in ambient air (also called “dry air” in Paper III and Paper IV), it was found that at relatively low temperatures (≤ 550 °C) the corrosivity of KBr and KF are similar to KCl. At 600 °C, KF showed much stronger corrosivity than KBr and KCl, especially for 10CrMo9-10 and AISI 347. When exposed to KBr or KF, 10CrMo9-10 was durable at least up to 450 °C, while AISI 347 and Sanicro 28 were durable at least up to 550 °C. From the laboratory corrosion tests in wet air (30% H2O), no obvious effect of water vapor was detected at 450 °C. At 550 °C, the influence of water vapor became significant in some cases, but the trend was not consistent. At 550 °C, after exposure with KBr, 10CrMo9-10 suffered from extreme corrosion; after exposure with KF and KCl, the corrosion was less severe, but still high. At 550 °C, local deep pitting corrosion occurred on AISI 347 and Sanicro 28 after exposure with KF. Some formation of K2CrO4 was observed in the oxide layer. At 550 °C, AISI 347 and Sanicro 28 suffered from low corrosion (oxide layer thickness of < 10 μm) after exposure with KBr and KCl. No formation of K2CrO4 was observed. Internal oxidation occurred in the cases of AISI 347 with KBr and KCl. From the laboratory corrosion tests in three different gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2), it was found that in tests with no salt, no corrosion occurred on AISI 347 and Sanicro 28 up to 600 °C in both the “O2-rich” (2% H2O-30% O2-N2) and “H2O-rich” (30% H2O-2% O2-N2) gas atmospheres; only 10CrMo9-10 showed increased corrosion with increasing temperature. For 10CrMo9-10 in the “O2-rich” atmosphere, the presence of KCl significantly increased the corrosion compared to the “no salt” cases. For 10CrMo9-10 in the “H2O-rich” atmosphere, the presence or absence of KCl did not show any big influence on corrosion. The formation of K2CrO4 was observed only in the case with the “O2-rich” atmosphere. Considering both the results from the BFB tests and the laboratory corrosion tests, if fuels containing Br were to be combusted, the corrosion damage of superheaters would be expected to be higher than if the fuels contain only Cl. Information generated from these studies can be used to help the boiler manufacturers in selecting materials for the most demanding combustion systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Suurten polttolaitosten päästöjen tarkkailu- ja raportointivaatimukset ovat uudistuneet viime vuosina paljon. Suurimpia muutosten aiheuttajia ovat Valtioneuvoston asetus 1017/2002 ja standardi EN-14181. Tässä työssä kuvataan uudet vaatimukset täyttävän päästöjen tarkkailu- ja raportointijärjestelmän rakentaminen monipolttoainekattilalle. Aluksi esitellään mitä uusia vaatimuksia päästöjen tarkkailulle ja raportoinnille on tullut viime aikoina. Lisäksi selvitetään vaatimusten mahdolliset ristiriidat ja ristiriitatilanteiden ratkaisutavat. Seuraavaksi esitellään vaatimukset täyttävän järjestelmän määritelmät. Erityisestiselvitetään kattilan erityispiirteiden vaatimia ratkaisuja. Lopuksi esitellään päästöjen tarkkailu- ja raportointijärjestelmän käyttökokemuksia ja parantamismahdollisuuksia. Kaikki tarkastelut tehdään ensisijaisesti toiminnanharjoittajan näkökulmasta. Järjestelmä toteutettiin Stora Enso Oyj:n Heinolan Flutingtehtaan voimalaitoksen pääkattilalle, jossa käytetään laajaa polttoainevalikoimaa. Toteutuspaikan valinta tehtiin sillä perusteella, että uudet päästöjen tarkkailu- ja raportointivaatimukset ovat erityisen haasteellisia monipolttoainekattiloiden tapauksessa. Työssä selvitetään järjestelmän soveltamismahdollisuuksia myös kahdella muulla Stora Enson tehtaalla. Käyttöönottovaiheen johtopäätöksenä todettiin päästöjen tarkkailu- ja raportointijärjestelmän täyttävän sille asetetut vaatimukset. Lisäksi havaittiin, että toiminnanharjoittajan kannattaa panostaa erityisesti järjestelmän joustavuuteen, luotettavuuteen, helppokäyttöisyyteen ja vikasietoisuuteen. Toiminnanharjoittaja pystyy määrittelyvaiheessa vaikuttamaan järjestelmän ominaisuuksiin helpommin ja edullisemmin kuin käyttöönoton jälkeen. Toiminnanharjoittajalta vaadittu työtuntimäärä arvioitiin Heinolan Flutingtehtaan tapauksen perusteella. Lopuksi selvitettiin mahdollisia tulevaisuuden kehityskohteita vastaavissa järjestelmissä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssäon tarkasteltu yleisesti höyrykattiloiden säilöntää. Erilaisten säilöntämenetelmien perustietojen lisäksi työssä on pyritty selvittämään eri kattilatyypeille ominaiset säilöntätavat. Märkäsäilönnän jälkeistä käyttöönottoa on pohdittu selvittämällä laskennallisesti, onko tarpeen vaihtaa kattilaan vahvasti kemikaloidun säilöntäliuoksen tilalle puhtaampaa syöttövettä. Esimerkkinä on käytetty Voikkaan paperitehtaan höyryvoimalaitoksen kattila K13:ta. Työtä tehdessä on käytetty apuna aihetta käsittelevää kirjallisuutta, jota on saatu höyrykattiloita säilöviltä voimalaitoksilta, kemikaalitoimittajilta sekä asiantuntijoiden tekemistä luentomonisteista. Lieriökattiloiden höyrypuoli säilötään lähes poikkeuksetta märkänä, sillä se on vaikea tyhjentää täysin kosteudesta. Läpivirtauskattilalaitoksella käytetään usein sekä kuiva- että märkäsäilöntää. Savukaasupuolen korroosio ehkäistään useinmiten pitämällä kattila niin lämpimänä, että kastepistealituksia ei tapahdu.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä on tehtyylläpitosuunnitelma Oulun Energian Toppila 1 - voimalaitokselle, jota on tavoitteena käyttää vuoteen 2015. Työssä on tarkasteltu aluksi voimalaitoksen tulevaisuuden käytön näkymiä ja tärkeimpien järjestelmien käyttökuntoa. Kattilalaitoksenkriittisille komponenteille on suoritettu ylläpito- ja epäkäytettävyyskustannusten vertailu sekä pyritty selvittämään komponenteille paras ylläpitomalli. Turbiinille on analysoitu erilaisia revisio- ja tarkastusmahdollisuuksia, ja vertailtu niistä muodostuvia kustannuksia. Tulosten perusteella voidaan sanoa, että tehostetut ylläpitotoimenpiteet ovat jatkossa kriittisille komponenteille taloudellisin ylläpitomalli, koska riittävällä määrällä tarkastuksia jakorjauksia voidaan hallita ongelmallisimpien komponenttien vaurioitumiskäyttäytymistä. Jos voimalaitosta käytetään vuoteen 2015, saattavat uusia investointeja olla eko I, eko II ja tertiääritulistin. Tämän työn perusteella investointeja eikannata tehdä, mutta komponenttien kuntoa sen sijaan on syytä arvioida vuosittain. Turbiinin kriittiset komponentit vaikuttaisivat olevan suhteellisen hyvässä kunnossa. Suurimmat vaurioitumismahdollisuudet liittyvät juoksusiipien väsymisvaurioihin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

 Diplomityön tarkoituksena on kehittää kolmiulotteinen malli kerrosleijupoltolle. Työn kirjallisuusosa sisältää seuraavat perusteet kerrosleijupolton tekniikasta: yleistiedot, leijutus- ja palamisilmiöt, kiinteän aineen ja kaasun sekoittuminen, päästöt ja lämmönsiirto. Lisäksi palamissysteemin mallinnuksen perusteet ja ratkaisumenetelmät ovat esitelty. Työn mallinnusosassa kehitetty koodi on ohjelmoitu Fortran-ohjelmointikielellä. Kehitetty malli perustuu olemassa olevaan malliin kiertoleijupoltosta. Yhtälö kiintoainekonsentraatioprofiilille on vaihdettu ja kiertovirta on poistettu koodista. Mallilla on tehty herkkyystarkasteluja polttoaineen ja kaasun sekoittumisen sekä reaktiokertoimen vaikutukselle. Visualisointi on tehty ohjelmassa Tecplot 360 ja mallinnustuloksia on vertailtu mitattuihin tuloksiin. Mallin laskemattulokset vastaavat hyvin mittaustuloksia ja kokemusperäisiä tietoja; monissa tapauksissa malli pystyy kvantitatiivisesti kuvaamaan parametrien variointia ja kaikissa tapauksissa malli antaa ainakin kvalitatiivisesti oikeita tuloksia. Työhön liittyvän kehityksen ja mallinnuskokemuksen perusteella on tehty ehdotukset mallin tulevaa kehitystä ja mittauksia varten.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kioton pöytäkirja velvoittaa teollisuusmaita vähentämään hiilidioksidipäästöjään. Energiantuotantolaitosten on vähennettävä tuotantoaan tai siirryttävä käyttämään vähäpäästöisempiä polttoaineita vähennystavoitteiden saavuttamiseksi. Etelä-Savon Energia Oy Mikkelissä rakentaa uuden kattilalaitoksen, joka soveltuu hiilidioksidivapaiden puupolttoaineiden polttoon. Kun uusi kattilalaitos otetaan käyttöön, kasvaa voimalaitoksen polttoaineiden kulutus 1,7 -kertaiseksi. Tämä merkitsee laitokselle tulevien polttoainekuljetusten määrän kasvamista kylmimpinä aikoina yli 70:neen autoon vuorokaudessa. Työssä on tarkasteltu nykyisen polttoaineiden vastaanoton ja kuljettimien kykyä ottaa vastaan kasvavat polttoainevirrat. Vastaanoton sujuvuus on polttoaineiden laadunhallinnan lisäksi edellytys laitoksen käytölle. Työn tavoitteena on ollut kartoittaa vastaanoton ongelmakohtia ja löytää näihin parannusmahdollisuuksia. Vastaanottokapasiteetti tulee venymään äärimmilleen tulevaisuudessa. Jotta määrällisesti riittävä ja laadullisesti sopiva polttoaineseos saadaan vastaanotettua nykyisenä vastaanottoaikana, tulee autojen saapua entistä tasaisemmin laitokselle. Tasainen saapuminen on mahdollista aikatauluttamalla sopivasti polttoainekuljetusten saapumisajat laitokselle. Vastaanoton kapasiteettia voitaisiin nostaa kasvattamalla kenttävaraston kokoa ja pienillä muutoksilla vastaanottoasemissa. Polttoaineen laadun ja vastaanoton tarkastelun lisäksi työssä on tarkasteltu polttoaineen saatavuutta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämän diplomityön oleellisempana tavoitteena oli tutkia ioninvaihtohartsien pitkäaikaista toiminnallista lämpötilakestävyyttä kirjallisuustutkimuksin ja kuormituskokein. Lisaksi työssä optimoitiin taloudellisesti ja teknisesti paras kytkentävaihtoehto soodakattilan lauhteenpuhdistuslaitokselle. Tässä diplomityössä selvitettiin myös soodakattilan ulospuhallusveden sisältämien veden jälkiannostelukemikaalien ja epäpuhtauksien vaikutusta ioninvaihtohartsien vanhenemiseen.; Ioninvaihtohartsien lämpötilakestävyyteen liittyvät koeajot suoritettiin Stora Enso Laminating Papers Oy Kotkan tehtaalla. Koeajoja varten oli erikseen suunniteltu koeajolaitteisto, jossa lauhdenäytettä puhdistettiin patruunasuotimella ja sekavaihtimella. Sekavaihtimessa käytettiin vahvoja anioni- ja kationihartseja. Koeajoja oli yhteensä neljäkappaletta ja niissä tutkittiin hartsien lämpötilakestävyyttä ja anionihartsin silikaatti-vuodon riippuvuutta lämpötilasta. Lämpötilakestävyyskoeajoissa käytetyt hartsit lähetettiin Rohm and Haasille analysoitavaksi. Lopulta koeajojen tuloksia verrattiin kirjallisuudessa esitettyihin aikaisempiin tutkimuksiin. Lauhteenpuhdistuslaitoksen kytkentävaihtoehtojen optimoinnissa käytettiin apuna Kotkan ja UPM-Kymmene Oyj Pietarsaaren tehtaiden kokemuksia. Kytkentävaihtoehtojen energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 -180 kg/s. Lisaksi selvitettiin kytkentävaihtoehtojen investointikustannukset ja kertakäyttöhartsien vuotuiset kustannukset laitokselle, jossa syöttöveden virtaus oli 67 kg/s. Ulospuhalluksen talteenottojärjestelmän energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 - 180 kg/s. Laskelmien lähtökohtana käytettiin kunkin soodakattilan ulospuhallusveden määriä, jotka selvitettiin tehdasvierailujen yhteydessä. Ulospuhallusveden epäpuhtauksien ja jälkiannostelukemikaalien pitoisuudet arvioitiin kattilaveden perusteella. Aikaisempien kokemusten perusteella arvioitiin, että ulospuhallusvesi johdettaisiin lisäveden valmistukseen ennen suolanpoistosarjoja. loninvaihtohartsien kuormituskokeiden ja kirjallisuustutkimusten perusteella oli selkeästi nähtävissä, että etenkin anionihartsin kapasiteetti heikkeni nopeasti lämpötilan ollessa yli 60 °C. Kationihartsin suolanpoistolle kriittinen lämpötilaraja on 100 °C.Lisäksi yli 60 °C:ssa anionihartsi ei pysty poistamaan silikaattia lauhteesta. Seuraavaksi on esitelty lauhteenpuhdistuslaitoksen optimikytkentävaihtoehdot sekä vanhoille että uusille laitoksille. Vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa on käytetty sekavaihdinta, paras kytkentävaihto on erilliset sekavaihtimet lauhteelle ja lisävedelle. Uudelle ja vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa ei ole käytetty sekavaihdinta, paras kytkentävaihto on yhteiset sekavaihtimet lauhteelle ja lisävedelle. Lauhteen puhdistuksessa käytetyt sekavaihtimen toimintalämpötila on 45 °C molemmissa kytkentävaihtoehdoissa. Kertakäyttöhartsien käyttö osoittautui suuressa mittakaavassa kannattamattomaksi. Tämä asia tarvinnee kuitenkin jatkotutkimuksia. Ulospuhallusveden talteenotolla saadaan energiasäästöä 6-53 k¤/a riippuenlaitoksesta. Etenkin soodakattilalaitoksissa, joissa soodakattila ja vedenkäsittelylaitos sijaitsevat lähellä toisiaan, kannattaa ulospuhallusvesi johtaa lisäveden valmistukseen. Jos edellä mainittujen laitosten etäisyydet kasvavat, saattavat ulospuhallusjärjestelmän investointi-kustannukset nousta kohtuuttoman suureksi. Tämä työ osoitti myös, että ulospuhallusveden epäpuhtauksilla ei ole merkittävää vaikutusta kemiallisesti puhdistetun veden laatuun ennen suolanpoistolaitosta ja ioninvaihtohartsien vanhenemiseen.