31 resultados para Lincoln Electric Light and Power Company


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this thesis was to identify the best grease removal technique with the application of low power of UV light to TiO2 coated grease filters. The treatment with various power series of ozone generating and ozone free lamps to normal grease filters and TiO2 coated grease filters were examined and the obtained results are compared to each other in this paper. The effect of ozone reaction was observed and compared with the effect of TiO2. The experiments were solely based on the photo oxidation and photo catalytic oxidation reactions. TiO2 is a green catalyst used in the photocatalytic reaction. Sunflower oil was used for grease production and tetracholoroethylene as a solvent. Grease samples were collected from the ventilation duct connected to the cooking hood system. Sample extraction was done in ultrasonic bath with the principle of sonication. The sample analysis was done by FTIR machine. The result determining the concentration of grease was the quantification of saturated C-H bonds in the chosen peak group of the spectrum. A very low power of UVC light functions perfectly with the Titanium dioxide. The experimental results have shown the combined treatment of titanium dioxide and UV light is an effective method in grease removal process. The photocatalytic reaction with titanium dioxide is better than photo oxidation reaction with ozone treatment. Photocatalytic reaction is environmentally friendly, energy efficient and economical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tutkimuksen päätavoite on arvioida, ovatko neljä ohjelmistovaihtoehtoa riittäviä tuotannon aikataulutuksen työkaluja ja mikä työkaluista sopii toimeksiantajayritykselle. Alatavoitteena on kuvata tuotannon aikataulutuksen nyky- ja tahtotila prosessimallinnuksen avulla, selvittää työkalun käyttäjätarpeet ja määritellä priorisoidut valintakriteerit työkalulle.Tutkimuksen teoriaosuudessa tutkitaan tuotannon aikataulutuksen logiikkaa ja haasteita. Työssä tarkastellaan aikataulutusohjelmiston valintaa rinnakkain prosessinmallinnuksen kanssa. Aikataulutusohjelmistovaihtoehdot ja metodit käyttäjätarpeiden selvittämiseksi käydään läpi. Empiriaosuudessa selvitetään tutkimuksen suhde toimeksiantajayrityksen strategiaan. Käyttäjätarpeet selvitetään haastattelujen avulla jaanalysoidaan QFD matriisin avulla. Toimeksiantajayrityksen tuotannon aikataulutuksen nyky- ja tahtotilaprosessit mallinnetaan, jotta ohjelmistojen sopivuutta, aikataulutusprosessia tukevana työkaluna voidaan arvioida.Tutkimustuloksena ovatpriorisoidut valintakriteerit aikataulutustyökalulle eli käyttäjätarpeista johdetut tärkeimmät toiminnalliset ominaisuudet, järjestelmätoimittaja-arvio sekä suositukset jatkotoimenpiteistä ja lisätutkimuksesta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Latinalaisen Amerikan osuus maailmantaloudesta on pieni verrattuna sen maantieteelliseen kokoon, väkilukuun ja luonnonvaroihin. Aluetta pidetään kuitenkin yhtenä tulevaisuuden merkittävistä kasvumarkkinoista. Useissa Latinalaisen Amerikan maissa on teollisuutta, joka hyödyntää luonnonvaroja ja tuottaa raaka-aineita sekä kotimaan että ulkomaiden markkinoille. Tällaisia tyypillisiä teollisuudenaloja Latinalaisessa Amerikassa ovat kaivos- ja metsäteollisuus sekä öljyn ja maakaasun tuotanto. Näiden teollisuudenalojen tuotantolaitteiden ja koneiden valmistusta ei Latinalaisessa Amerikassa juurikaan ole. Ne tuodaan yleensä Pohjois-Amerikasta ja Euroopasta. Tässä diplomityössä tutkitaan sähkömoottorien ja taajuusmuuttajien markkinapotentiaalia Latinalaisessa Amerikassa. Tutkimuksessa perehdytään Latinalaisen Amerikan maiden kansantalouksien tilaan sekä arvioidaan sähkömoottorien ja taajuusmuuttajien markkinoiden kokoa tullitilastojen avulla. Chilen kaivosteollisuudessa arvioidaan olevan erityistä potentiaalia. Diplomityössä selvitetään ostoprosessin kulkua Chilen kaivosteollisuudessa ja eri asiakastyyppien roolia siinä sekä tärkeimpiä päätöskriteerejä toimittaja- ja teknologiavalinnoissa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tutkimuksen tarkoituksena oli selvittää typenoksidien vähennysmahdollisuudet Stora Enson Varkauden tehtaiden sellutehtaalla ja voimalaitoksella. Tutkimuksessa käsiteltiin tehdasalueen suurimpia typenoksidien päästölähteitä: soodakattilaa, meesauunia, kuorikattilaa, öljykattilaa ja muovi-alumiinijakeen kaasutuslaitosta. Tutkimuksessa selvitettiin typenoksidipäästöjen syntymekanismit ja erilaisiin polttotekniikoihin soveltuvat typenoksidien vähennystekniikat. Varkauden tehtaiden typenoksidien vuosipäästö vuonna 2001 oli 836 tonnia. Kansallinen lainsäädäntö, kansainväliset sopimukset sekä paras käytettävissä oleva tekniikka (BAT) huomioiden selvitettiin kuhunkin kohteeseen parhaiten soveltuvat ratkaisut. Tutkimuksen perusteella laadittiin toimenpideohjelma, joka määrittelee suositeltavan toteutusjärjestyksen typenoksidien vähennystoimenpiteille. Toimenpideohjelman tärkeimpinä kriteereinä pidettiin vuonna 2004 tulevan uuden ympäristöluvan arvioituja luparajoja sekä toimenpiteiden kustannustehokkuutta. Toteutusjärjestyksessä ensimmäiseksi valittiin koeajojakson järjestäminen ajon optimoimiseksi kiertopetikattilalla ja toiseksi meesauunin ajon optimointi jatkuvatoimisen NOx-analysaattorin avulla. Seuraaviksi toimenpiteiksi ehdotettiin vertikaali-ilmajärjestelmän käyttöönottoa soodakattilalla sekä SNCR-järjestelmän asennusta kuorikattilalle. Saavutettava NOx-vähennys tulisi olemaan 10 – 45 % ja hinta 30 – 3573 EUR vähennettyä NOx-tonnia kohti. Tutkimuksen osana Ilmatieteen laitoksella teetetyn typenoksidien leviämisselvityksen mukaan Stora Enson tehtaiden NOx-päästöjen vaikutus Varkauden ilmanlaatuun on hyvin pieni. Suurin osa NOx-päästöistä aiheutuu liikenteestä.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reliable detection of intrapartum fetal acidosis is crucial for preventing morbidity. Hypoxia-related changes of fetal heart rate variability (FHRV) are controlled by the autonomic nervous system. Subtle changes in FHRV that cannot be identified by inspection can be detected and quantified by power spectral analysis. Sympathetic activity relates to low-frequency FHRV and parasympathetic activity to both low- and high-frequency FHRV. The aim was to study whether intra partum fetal acidosis can be detected by analyzing spectral powers of FHRV, and whether spectral powers associate with hypoxia-induced changes in the fetal electrocardiogram and with the pH of fetal blood samples taken intrapartum. The FHRV of 817 R-R interval recordings, collected as a part of European multicenter studies, were analyzed. Acidosis was defined as cord pH ≤ 7.05 or scalp pH ≤ 7.20, and metabolic acidosis as cord pH ≤ 7.05 and base deficit ≥ 12 mmol/l. Intrapartum hypoxia increased the spectral powers of FHRV. As fetal acidosis deepened, FHRV decreased: fetuses with significant birth acidosis had, after an initial increase, a drop in spectral powers near delivery, suggesting a breakdown of fetal compensation. Furthermore, a change in excess of 30% of the low-to-high frequency ratio of FHRV was associated with fetal metabolic acidosis. The results suggest that a decrease in the spectral powers of FHRV signals concern for fetal wellbeing. A single measure alone cannot be used to reveal fetal hypoxia since the spectral powers vary widely intra-individually. With technical developments, continuous assessment of intra-individual changes in spectral powers of FHRV might aid in the detection of fetal compromise due to hypoxia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Då aktivister i den sydafrikanska organisationen Treatment Action Campaign - TAC- demonstrerar för tillgång till bromsmediciner för den fattiga delen av världen, iklädda T-skjortor med texten "HIV-POSITIV", är de offer samtidigt som de är globala aktörer för en rättvisare värld. Denna typ av aktivism, och särskilt mobiliseringen av kvinnor som lever med hiv och kämpar för tillgång till bromsmediciner, utmanar aktuell, hälso- och hiv-forskning. Vidare kastar hiv-aktivismen ljus på globaliseringens effekter på sjukdom och hälsa. TAC är en hälsorörelse som fokuserar på hiv på såväl ett personligt, nationellt som globalt plan. Genom sitt breda perspektiv förskjuter TAC frågan om hiv från att handla om individuell sjukdom till att beröra ett brett spektrum av politiska frågor. Studien "Long Live! HIV-aktivism, knowledge and power", som grundar sig på ett rikt etnografisk material insamlat i Sydafrika under åren 200-2006, visar hur hiv-aktivisterna utmanar dikotomier mellan socialt och medicinskt, mellan behandling och prevention samt mellan aktör och offer. I TAC:s arbete dekonstrueras också de ofta skarpa konstrasterna mellan expert- och lekmannakunskap, eftersom organisationen belyser hur läkare, patienter och aktivister kan samarbeta för en fungerande hälsovård. Studien granskar hur TAC-aktivister, som lever med hiv, agerar som globala aktörer i sitt arbete för förändring. Studien visar vidare hur TAC-aktivister utmanar hur hiv-prevention och -behandling sätts i motsatsförhållande till varandra och hävdar att man inte kan ha det ena utan det andra. Man kan säga att aktivisternas kritik av hälsopolitik synliggör hur teorier om hälsa och sjukdom, måste ta i beaktande det komplexa förhållandet mellan kön, ras, klass och globala maktstrukturer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This master’s thesis was done for a small company, Vipetec Oy, which offers specialized technological services for companies mainly in forest industry. The study was initiated partly because the company wants to expand its customer base to a new industry. There were two goals connected to each other. First was to find out how much and what kind of value current customers have realized from ATA Process Event Library, one of the products that the company offers. Second was to determine the best way to present this value and its implications for future value potential to both current and potential customers. ATA helps to make grade and product changes, starting after machine downtime, and recovery from production break faster for customers. All three events sometimes occur in production line. The faster operation results to savings in time and material. In addition to ATA Vipetec also offers other services related to development of automation and optimization of controls. Theoretical part concentrates on the concept of value, how it can be delivered to customers, and what kind of risk customer faces in industrial purchasing. Also the function of reference marketing towards customers is discussed. In the empirical part the realized value for existing customers is evaluated based on both numerical data and interviews. There’s also a brief case study about one customer. After that the value-based reference marketing for a target industry is examined through interviews of these potential customers. Finally answers to the research questions are stated and compared also to the theoretical knowledge about the subject. Results show that those customers’ machines which use the full service concept of ATA usually are able to save more time and material than the machines which use only some features of the product. Interviews indicated that sales arguments which focus on improved competitive status are not as effective as current arguments which focus on numerical improvements. In the case of potential customers in the new industry, current sales arguments likely work best for those whose irregular production situations are caused mainly by fault situations. When the actions of Vipetec were compared to ten key elements of creating customer references, it was seen that many of them the company has either already included in its strategy or has good chances to include them with the help of the results of this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Data transmission between an electric motor and a frequency converter is required in variablespeed electric drives because of sensors installed at the motor. Sensor information can be used for various useful applications to improve the system reliability and its properties. Traditionally, the communication medium is implemented by an additional cabling. However, the costs of the traditional method may be an obstacle to the wider application of data transmission between a motor and a frequency converter. In any case, a power cable is always installed between a motor and a frequency converter for power supply, and hence it may be applied as a communication medium for sensor level data. This thesis considers power line communication (PLC) in inverter-fed motor power cables. The motor cable is studied as a communication channel in the frequency band of 100 kHz−30 MHz. The communication channel and noise characteristics are described. All the individual components included in a variable-speed electric drive are presented in detail. A channel model is developed, and it is verified by measurements. A theoretical channel information capacity analysis is carried out to estimate the opportunities of a communication medium. Suitable communication and forward error correction (FEC) methods are suggested. A general method to implement a broadband and Ethernet-based communication medium between a motor and a frequency converter is proposed. A coupling interface is also developed that allows to install the communication device safely to a three-phase inverter-fed motor power cable. Practical tests are carried out, and the results are analyzed. Possible applications for the proposed method are presented. A speed feedback motor control application is verified in detail by simulations and laboratory tests because of restrictions for the delay in the feedback loop caused by PLC. Other possible applications are discussed at a more general level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In liberalized electricity markets, which have taken place in many countries over the world, the electricity distribution companies operate in the competitive conditions. Therefore, accurate information about the customers’ energy consumption plays an essential role for the budget keeping of the distribution company and for correct planning and operation of the distribution network. This master’s thesis is focused on the description of the possible benefits for the electric utilities and residential customers from the automatic meter reading system usage. Major benefits of the AMR, illustrated in the thesis, are distribution network management, power quality monitoring, load modelling, and detection of the illegal usage of the electricity. By the example of the power system state estimation, it was illustrated that even the partial installation of the AMR in the customer side leads to more accurate data about the voltage and power levels in the whole network. The thesis also contains the description of the present situation of the AMR integration in Russia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electric energy demand has been growing constantly as the global population increases. To avoid electric energy shortage, renewable energy sources and energy conservation are emphasized all over the world. The role of power electronics in energy saving and development of renewable energy systems is significant. Power electronics is applied in wind, solar, fuel cell, and micro turbine energy systems for the energy conversion and control. The use of power electronics introduces an energy saving potential in such applications as motors, lighting, home appliances, and consumer electronics. Despite the advantages of power converters, their penetration into the market requires that they have a set of characteristics such as high reliability and power density, cost effectiveness, and low weight, which are dictated by the emerging applications. In association with the increasing requirements, the design of the power converter is becoming more complicated, and thus, a multidisciplinary approach to the modelling of the converter is required. In this doctoral dissertation, methods and models are developed for the design of a multilevel power converter and the analysis of the related electromagnetic, thermal, and reliability issues. The focus is on the design of the main circuit. The electromagnetic model of the laminated busbar system and the IGBT modules is established with the aim of minimizing the stray inductance of the commutation loops that degrade the converter power capability. The circular busbar system is proposed to achieve equal current sharing among parallel-connected devices and implemented in the non-destructive test set-up. In addition to the electromagnetic model, a thermal model of the laminated busbar system is developed based on a lumped parameter thermal model. The temperature and temperature-dependent power losses of the busbars are estimated by the proposed algorithm. The Joule losses produced by non-sinusoidal currents flowing through the busbars in the converter are estimated taking into account the skin and proximity effects, which have a strong influence on the AC resistance of the busbars. The lifetime estimation algorithm was implemented to investigate the influence of the cooling solution on the reliability of the IGBT modules. As efficient cooling solutions have a low thermal inertia, they cause excessive temperature cycling of the IGBTs. Thus, a reliability analysis is required when selecting the cooling solutions for a particular application. The control of the cooling solution based on the use of a heat flux sensor is proposed to reduce the amplitude of the temperature cycles. The developed methods and models are verified experimentally by a laboratory prototype.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of VSC-HVDC technology throughout the world has turned out to be an efficient solution regarding a large share of wind power in different power systems. This technology enhances the overall reliability of the grid by utilization of the active and reactive power control schemes which allows to maintain frequency and voltage on busbars of the end-consumers at the required level stated by the network operator. This master’s thesis is focused on the existing and planned wind farms as well as electric power system of the Åland Islands. The goal is to analyze the wind conditions of the islands and appropriately predict a possible production of the existing and planned wind farms with a help of WAsP software program. Further, to investigate the influence of increased wind power it is necessary to develop a simulation model of the electric grid and VSC-HVDC system in PSCAD and examine grid response to different wind power production cases with respect to the grid code requirements and ensure the stability of the power system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reformation of power sector is still in the process of development. The present day situation in Russian electricity power market ischaracterized as transitional period: competitive electricity market is forming, new companies are being created and the power of government regulation is decreasing. The main aim of the reformation is to attract much-needed private investments to the power sector. The electricity consumption increases very rapidly and power sector has to cope with high demand. The goal of this master's thesis is to analyze the nowadays situation in Russian power sector, such as generation structure, condition of electricity networks, electricity price formation for end-users, shape of fuel sector and investments risks and attraction.The final result of this work is creation of scenario of Russian power sector future shape and analysis of the present day situation.