77 resultados para swine effluent
em Université de Lausanne, Switzerland
Resumo:
Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.
Resumo:
Doxorubicin is an antineoplasic agent active against sarcoma pulmonary metastasis, but its clinical use is hampered by its myelotoxicity and its cumulative cardiotoxicity, when administered systemically. This limitation may be circumvented using the isolated lung perfusion (ILP) approach, wherein a therapeutic agent is infused locoregionally after vascular isolation of the lung. The influence of the mode of infusion (anterograde (AG): through the pulmonary artery (PA); retrograde (RG): through the pulmonary vein (PV)) on doxorubicin pharmacokinetics and lung distribution was unknown. Therefore, a simple, rapid and sensitive high-performance liquid chromatography method has been developed to quantify doxorubicin in four different biological matrices (infusion effluent, serum, tissues with low or high levels of doxorubicin). The related compound daunorubicin was used as internal standard (I.S.). Following a single-step protein precipitation of 500 microl samples with 250 microl acetone and 50 microl zinc sulfate 70% aqueous solution, the obtained supernatant was evaporated to dryness at 60 degrees C for exactly 45 min under a stream of nitrogen and the solid residue was solubilized in 200 microl of purified water. A 100 microl-volume was subjected to HPLC analysis onto a Nucleosil 100-5 microm C18 AB column equipped with a guard column (Nucleosil 100-5 microm C(6)H(5) (phenyl) end-capped) using a gradient elution of acetonitrile and 1-heptanesulfonic acid 0.2% pH 4: 15/85 at 0 min-->50/50 at 20 min-->100/0 at 22 min-->15/85 at 24 min-->15/85 at 26 min, delivered at 1 ml/min. The analytes were detected by fluorescence detection with excitation and emission wavelength set at 480 and 550 nm, respectively. The calibration curves were linear over the range of 2-1000 ng/ml for effluent and plasma matrices, and 0.1 microg/g-750 microg/g for tissues matrices. The method is precise with inter-day and intra-day relative standard deviation within 0.5 and 6.7% and accurate with inter-day and intra-day deviations between -5.4 and +7.7%. The in vitro stability in all matrices and in processed samples has been studied at -80 degrees C for 1 month, and at 4 degrees C for 48 h, respectively. During initial studies, heparin used as anticoagulant was found to profoundly influence the measurements of doxorubicin in effluents collected from animals under ILP. Moreover, the strong matrix effect observed with tissues samples indicate that it is mandatory to prepare doxorubicin calibration standard samples in biological matrices which would reflect at best the composition of samples to be analyzed. This method was successfully applied in animal studies for the analysis of effluent, serum and tissue samples collected from pigs and rats undergoing ILP.
Resumo:
Application of wild-type or genetically-modified bacteria to the soil environment entails the risk of dissemination of these organisms to the groundwater. To measure vertical transport of bacteria under natural climatic conditions, Pseudomonas fluorescens strain CHA0 was released together with bromide as a mobile tracer at the surface of large outdoor lysimeters. Two experiments, one starting in autumn 1993 and the other in spring 1994 were performed. Shortly after a heavy rainfall in late spring 1994, the released bacteria were detected for the first time in effluent water from the 2.5-m-deep lysimeters in both experiments, i.e. 210 d and 21 d, respectively, after inoculation. Only a 10−9 to 10−8 fraction of the inoculum was recovered as culturable cells in the effluent water, but a larger fraction of the CHA0 cells was in a non-culturable state as detected with immunofluorescence microscopy. As much as 50% of the mobile tracer percolated through the lysimeters, indicating that, compared with bromide, bacterial cells were retained in soil. In the second part of this study, persistence of CHA0 in groundwater microcosms consisting of lysimeter effluent water was studied for 380 d. Survival of the inoculant as culturable cells was better under anaerobic than under aerobic conditions. However, a large fraction of the cells became non-culturable in both cases. When the experiment was performed with filter-sterilized effluent water, the total count of introduced bacteria did not decline with time. In conclusion, the biocontrol strain was transported in low numbers to a potential groundwater level under natural climatic conditions, but could persist for an extended period in groundwater microcosms.
Resumo:
To avoid the exclusive use of rodent monoclonal antibodies (MAbs) in patients for the detection of tumors by immunoscintigraphy and for radioimmunotherapy, swine MAbs were produced that are directed against carcinoembryonic antigen (CEA). Spleen cells from 2 pigs immunized with purified colon carcinoma CEA were fused with a nonsecreting mouse myeloma cell line by conventional methods, except that a particularly long immunization protocol and large amounts of spleen and myeloma cells were used. Of 1,200 growing hybrids tested, 20 were found initially to produce antibodies binding to radiolabeled CEA. Seven stable clones producing anti-CEA MAbs for more than 6 months were derived from these hybrids by repeated subcloning. The pig origin of the seven MAbs was demonstrated in a solid-phase CEA enzyme immunoassay where anti-pig immunoglobin (Ig) antibodies coupled to peroxidase gave a positive reaction while anti-mouse Ig antibodies were entirely negative. All swine MAbs were of the IgG isotype. Three anti-CEA MAbs showed no cross-reactivity with granulocytes, while four others gave various degrees of reactivity with different granulocyte glycoproteins. Competitive binding to CEA performed for two purified swine MAbs showed that they recognized two different epitopes. The affinity constants measured for these two MAbs by Scatchard plot on purified CEA were high (1.2 X 10(9) and 1.2 X 10(10) liter/mol). One of the MAbs was tested in vivo for tumor localization by injection, after radiolabeling, in nude mice bearing human colon carcinoma xenograft. High ratios of tumor to normal tissue were obtained with mean values of 10.5 for intact MAbs and of 26.8 for F(ab')2 fragments of the porcine MAb. The results showed that heterofusion with this particular protocol can be used to produce swine MAbs of high affinity and specificity for a well-defined tumor marker. These reagents may have an important clinical utility, particularly in patients who became sensitized to mouse immunoglobulins.
Resumo:
Feelings of invulnerability, seen in judgments of 0% risk, can reflect misunderstandings of risk and risk behaviors, suggesting increased need for risk communication. However, judgments of 0% risk may be given by individuals who feel invulnerable, and by individuals who are rounding from small non-zero probabilities. We examined the effect of allowing participants to give more precise responses in the 0-1% range on the validity of reported probability judgments. Participants assessed probabilities for getting H1N1 influenza and dying from it conditional on infection, using a 0-100% visual linear scale. Those responding in the 0-1% range received a follow-up question with more options in that range. This two-step procedure reduced the use of 0% and increased the resolution of responses in the 0-1% range. Moreover, revised probability responses improved predictions of attitudes and self-reported behaviors. Hence, our two-step procedure allows for more precise and more valid measurement of perceived invulnerability. [Authors]
Resumo:
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Augmentation cystoplasty using pedicled and de-epithelialized gastric patches in the mini-pig model.
Resumo:
PURPOSE: The most common methods of bladder augmentation are gastrocystoplasty and enterocystoplasty. Gastrocystoplasty is advantageous due to minimal mucous secretion and a well developed muscular wall as well as good urodynamic properties of the patch. However, the permanent contact of urine with the gastric mucosa is not free of complications. We report the urodynamic, macroscopic and histological outcomes of a pedicled de-epithelialized gastric patch incorporated in the bladder. We compared the results to those of our previous study, which sought to analyze these techniques of patch coverage using sigmoid patches. MATERIALS AND METHODS: We performed 20 augmentation cystoplasties in the mini-pig model using a pedicled de-epithelialized gastric patch and 5 techniques of patch coverage. RESULTS: Three months after surgery all bladders had an increase in volume except those in which the auto-augmentation technique was used. However, all gastric patches were smaller compared to preoperative size. Many had irregular fibrosed inner surfaces and histological evaluation revealed a fibrosed newly formed submucosal layer with a complete urothelial coverage in every patch. No gastric mucosal remnant was found. CONCLUSIONS: De-epithelialized gastrocystoplasty is an attractive procedure that can increase bladder capacity as well as provide a complete urothelial lining without mucosal remnants. However, the success of this procedure seems to be limited by increased morbidity and fibrotic changes, and decreased surface of the patch.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Resumo:
Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.
Resumo:
The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.
Resumo:
In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.
Resumo:
Dynamic assembly and disassembly of microtubules is essential for cell division, cell movements, and intracellular transport. In the developing nervous system, microtubule dynamics play a fundamental role during neurite outgrowth, elongation, and branching, but the molecular mechanisms involved are unknown. SCG10 is a neuron-specific protein that is membrane-associated and highly enriched in growth cones. Here we show that SCG10 binds to microtubules, inhibits their assembly, and can induce microtubule disassembly. We also show that SCG10 overexpression enhances neurite outgrowth in a stably transfected neuronal cell line. These data identify SCG10 as a key regulator of neurite extension through regulation of microtubule instability.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.