Decreased compliance on arterial anastomoses.
Data(s) |
2000
|
---|---|
Resumo |
The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery. |
Identificador |
http://serval.unil.ch/?id=serval:BIB_13FBBEC3AC80 isbn:1023-9332 pmid:10786109 |
Idioma(s) |
en |
Fonte |
Swiss surgery = Schweizer Chirurgie = Chirurgie suisse = Chirurgia svizzera, vol. 6, no. 2, pp. 77-9 |
Palavras-Chave | #Anastomosis, Surgical; Animals; Blood Pressure; Carotid Arteries; Compliance; Muscle, Smooth, Vascular; Postoperative Complications; Pulsatile Flow; Swine |
Tipo |
info:eu-repo/semantics/article article |