269 resultados para ultrasound measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiological investigations using gadolinium or intravenous iodinated contrast products are used cautiously in patients suffering from chronic kidney disease because of their risk of acute kidney injury and systemic nephrogenic fibrosis. In this article, we review several radiological alternatives that can be useful to obtain renal anatomical and/or functional information in this patient population. The basic principles, indications, and advantages and limitations of Doppler ultrasound with measurement of the resistance index, contrast-enhanced ultrasound, and a technique called BOLD-MRI (blood-oxygenation level dependent-MRI) are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The primary aim of the study was to evaluate whether rheumatoid arthritis (RA) patients considered to be in remission according to clinical criteria sets still had persisting ultrasound (US) synovitis. We further intended to evaluate the capacity of our US score to discriminate between the patients with a clinically active disease versus those in remission. METHODS: This is an observational study nested within the Swiss Clinical Quality Management in Rheumatic Diseases (SCQM) rheumatoid arthritis cohort. A validated US score (SONAR score) based on a semi-quantitative B-mode and Doppler (PwD) score as part of the regular clinical workup by rheumatologists in different clinical settings was used. To define clinically relevant synovitis, the same score was applied to 38 healthy controls and the 90st percentile was used as cut-off for 'relevant' synovitis. RESULTS: Three hundred and seven patients had at least one US examination and concomitant clinical information on disease activity. More than a third of patients in both DAS28 and ACR/EULAR remission showed significant gray scale synovitis (P=0.01 and 0.0002, respectively) and PwD activity (P=0.005 and 0.0005, respectively) when compared to controls. The capacity of US to discriminate between the two clinical remission groups and patients with active disease was only moderate. CONCLUSION: This observational study confirms that many patients considered to be in clinical remission according the DAS and the ACR/EULAR definitions still have residual synovitis on US. The prognostic significance of US synovitis and the exact place of US in patients reaching clinical remission need to be further evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'activation des mastocytes se produit dans plusieurs conditions pathologiques et est principalement observée chez des patients développant une réaction anaphylactique. Dans la pratique clinique, la mesure de l'histamine et de ses métabolites dans le plasma et dans l'urine du patient peut être effectuée et montre parfois des résultats aussi précis que la mesure de la beta-tryptase dans le sang lorsqu'il est nécessaire de confirmer une activation mastocytaire. En revanche, la mesure de la beta tryptase dans l'urine dans un but diagnostic n'a que rarement été effectuée sur des personnes vivantes et a montré des résultats contradictoires. Dans le domaine de la médecine légale, la mesure de la beta-tryptase dans un but diagnostic est effectuée dans le sérum postmortem obtenu à partir de sang prélevé au niveau fémoral. Cependant, le sang peut être partiellement ou complètement indisponible dans certains cas spécifiques, dans les autopsies de nourrissons ou de corps sévèrement mutilés par exemple. Un des buts de notre étude est d'évaluer la pertinence de la mesure de la beta-tryptase dans des échantillons biologiques alternatifs, à savoir dans l'urine, l'humeur vitrée et le liquide péricardique. Pour cela nous avons sélectionné 94 cas d'autopsies comprenant 6 cas de réaction anaphylactique suite à l'administration de produits de contraste radiologique, 10 cas d'hypothermie, 10 cas d'acidocétose diabétique, 10 cas de suicide par arme à feu, 18 cas de décès consécutif à une injection d'héroïne, 10 cas de décès traumatiques, 10 cas de mort subite avec peu ou pas d'athérosclérose coronarienne, 10 cas de décès avec une athérosclérose coronarienne sévère mais sans signe d'infarctus du myocarde et 10 cas de décès consécutif à un infarctus du myocarde avec une athérosclérose coronarienne sévère. Dans tous les cas de réaction anaphylactique suite à l'administration de produit de contraste radiologique, les concentrations de beta-tryptase, mesurées dans le sérum postmortem et dans le liquide péricardique, ont montré des valeurs plus élevées que le seuil clinique de référence (11 ng/l) et le seuil postmortem de référence (45 ng/l). La concentration de beta-tryptase mesurée dans l'urine et l'humeur vitrée a montré des valeurs inférieures au seuil clinique dans tous les cas de notre étude. La mesure de la concentration de beta tryptase dans le liquide péricardique semble donc une alternative valable à la mesure dans le sérum postmortem, lorsque le sang fémoral n'est pas disponible durant l'autopsie, afin de poser un diagnostic de réaction anaphylactique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary points: - The bias introduced by random measurement error will be different depending on whether the error is in an exposure variable (risk factor) or outcome variable (disease) - Random measurement error in an exposure variable will bias the estimates of regression slope coefficients towards the null - Random measurement error in an outcome variable will instead increase the standard error of the estimates and widen the corresponding confidence intervals, making results less likely to be statistically significant - Increasing sample size will help minimise the impact of measurement error in an outcome variable but will only make estimates more precisely wrong when the error is in an exposure variable

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed Tomography (CT) represents the standard imaging modality for tumor volume delineation for radiotherapy treatment planning of retinoblastoma despite some inherent limitations. CT scan is very useful in providing information on physical density for dose calculation and morphological volumetric information but presents a low sensitivity in assessing the tumor viability. On the other hand, 3D ultrasound (US) allows a highly accurate definition of the tumor volume thanks to its high spatial resolution but it is not currently integrated in the treatment planning but used only for diagnosis and follow-up. Our ultimate goal is an automatic segmentation of gross tumor volume (GTV) in the 3D US, the segmentation of the organs at risk (OAR) in the CT and the registration of both modalities. In this paper, we present some preliminary results in this direction. We present 3D active contour-based segmentation of the eye ball and the lens in CT images; the presented approach incorporates the prior knowledge of the anatomy by using a 3D geometrical eye model. The automated segmentation results are validated by comparing with manual segmentations. Then, we present two approaches for the fusion of 3D CT and US images: (i) landmark-based transformation, and (ii) object-based transformation that makes use of eye ball contour information on CT and US images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.