116 resultados para Lecture Performance
Resumo:
The aim of this study was to examine the effect of an individualized overground walking interval training on gait performance [i.e., speed and energy cost (C(w))] in healthy elderly individuals. Twenty-two older adults were assigned to either a training group (TG; n=12, 73.4+/-3.9yr) or a non-training control group (CG; n=10, 70.9+/-9.6yr). TG participated in a 7-week individualized walking interval training at intensities progressing from 50 to 100% of ventilatory threshold (T (VE)). Aerobic fitness [maximal oxygen uptake (V O(2max)) and T (VE)], preferred walking speed (PWS), gross and net C(w) (GC(w) and NC(w), respectively) and relative effort (%V O(2max)) at PWS measured before training (PWS(1)) were assessed prior and following the intervention. All outcomes were measured on a treadmill. Significant improvements in GC(w) (-8%; P=0.007), NC(w) (-12%; P=0.003), relative effort (%V O(2max): -12%; P<0.001) and PWS (+12%; P<0.001) were observed in TG but not in CG (P>0.71). V O(2max) and T (VE) remained unchanged in both groups (P>0.57). Changes in GC(w) at PWS(1) (difference between GC(w) at PWS(1) measured pre and post intervention) were inversely correlated with changes in PWS (difference between pre and post PWS; r=-0.67; P=0.02). The decreased C(w) at PWS(1), with no concomitant improvement in aerobic fitness, represents the main contributing factor for the reduction of the relative effort at this speed. This also allows elderly people to increase their PWS post training. Therefore, the present walking training may be an effective way to improve walking performance and delay mobility impairment in older adults.
Resumo:
Several studies (on an inclined platform or with special shoes) have reported improved jump performance when the ankle was in a dorsiflexion (DF) position. The present study aims to test whether shoes inducing moderate DF modify vertical jump performance and energy cost. Twenty-one young, healthy female subjects (30 +/- 6 yr, 58 +/- 6 kg, O2max 45 +/- 3 mLxkg-1xmin-1, mean +/- SD) participated in the study. Jump performance was tested with subjects either wearing 4 degrees DF or standard (S) shoes. The jump tests (performed on a force platform) consisted of squat jump (SJ), countermovement jump (CMJ), and continuous jumps (CJ) during 15 seconds. Measured parameters were jump height, speed at take off, and maximal and average power. Oxygen uptake was measured on a treadmill while subjects ran at 95% of the anaerobic threshold during a 7-minute steady-state period. As compared with S shoes, DF shoes significantly improved the height of SJ (31 +/- 4 cm vs. 34 +/- 4 cm, p = 0.0001), CMJ (32 +/- 4 cm vs. 34 +/- 4 cm, p = 0.0004), and CJ (17.5 +/- 4.2 cm vs. 22.0 +/- 6.0 cm, p = 0.0001). Speed at take off was also significantly higher. Mean power significantly increased in SJ and CJ but not in CMJ. Oxygen uptake was not different between conditions (p = 0.40). Dorsiflexion shoes induce a significant increase in jump performance. These results are in accordance with the concept that a DF of the ankle may induce an increase of the length and strength of the triceps surae (higher torque). However, wearing DF shoes did not require more energy during running. Dorsiflexion shoes could be used to increase jump performance in several sports such as volleyball in which jump height is essential.
Resumo:
Many firms around the world are managed and partially owned by entrepreneurs. These entrepreneurs hold under diversified portfolios and, therefore, bear idiosyncratic risk in addition to systematic risk. To compensate the additional risk borne, they extract private benefits. In this paper, we analyse how an entrepreneur's overconfidence affects the market performance of the firm, through the channel of private benefits. We show that two dimensions of overconfidence, namely overestimation of future cash-flows and underestimation of idiosyncratic risk (called miscalibration), have opposite effects on the private benefits extracted by the entrepreneur. As a consequence, firms managed and partially owned by overconfident entrepreneurs can deliver overperformance or underperformance, depending on the prevalence of overestimation or miscalibration of the beliefs of the entrepreneur.
Resumo:
ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.
Resumo:
BACKGROUND: Surgeons' personalities have been described as different from those of the general population, but this was based on small descriptive studies limited by the choice of evaluation instrument. Furthermore, although the importance of the human factor in team performance has been recognized, the effect of personality traits on technical performance is unknown. This study aimed to compare surgical residents' personality traits with those of the general population and to evaluate whether an association exists between their personality traits and technical performance using a virtual reality (VR) laparoscopy simulator. METHODS: In this study, 95 participants (54 residents with basic, 29 with intermediate laparoscopic experience, and 12 students) underwent personality assessment using the NEO-Five Factor Inventory and performed five VR tasks of the Lap Mentor? basic tasks module. The residents' personality traits were compared with those of the general population, and the association between VR performance and personality traits was investigated. RESULTS: Surgical residents showed personality traits different from those of the general population, demonstrating lower neuroticism, higher extraversion and conscientiousness, and male residents showed greater openness. In the multivariable analysis, adjusted for gender and surgical experience, none of the personality traits was found to be an independent predictor of technical performance. CONCLUSIONS: Surgical residents present distinct personality traits that differ from those of the general population. These traits were not found to be associated with technical performance in a virtual environment. The traits may, however, play an important role in team performance, which in turn is highly relevant for optimal surgical performance.
Resumo:
The purpose of this study was to examine the relationship between skeletal muscle monocarboxylate transporters 1 and 4 (MCT1 and MCT4) expression, skeletal muscle oxidative capacity and endurance performance in trained cyclists. Ten well-trained cyclists (mean +/- SD; age 24.4 +/- 2.8 years, body mass 73.2 +/- 8.3 kg, VO(2max) 58 +/- 7 ml kg(-1) min(-1)) completed three endurance performance tasks [incremental exercise test to exhaustion, 2 and 10 min time trial (TT)]. In addition, a muscle biopsy sample from the vastus lateralis muscle was analysed for MCT1 and MCT4 expression levels together with the activity of citrate synthase (CS) and 3-hydroxyacyl-CoA dehydrogenase (HAD). There was a tendency for VO(2max) and peak power output obtained in the incremental exercise test to be correlated with MCT1 (r = -0.71 to -0.74; P < 0.06), but not MCT4. The average power output (P (average)) in the 2 min TT was significantly correlated with MCT4 (r = -0.74; P < 0.05) and HAD (r = -0.92; P < 0.01). The P (average) in the 10 min TT was only correlated with CS activity (r = 0.68; P < 0.05). These results indicate the relationship between MCT1 and MCT4 as well as cycle TT performance may be influenced by the length and intensity of the task.
Resumo:
A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.