193 resultados para Measurement uncertainty


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Alcohol is a major risk factor for burden of disease and injuries globally. This paper presents a systematic method to compute the 95% confidence intervals of alcohol-attributable fractions (AAFs) with exposure and risk relations stemming from different sources.Methods: The computation was based on previous work done on modelling drinking prevalence using the gamma distribution and the inherent properties of this distribution. The Monte Carlo approach was applied to derive the variance for each AAF by generating random sets of all the parameters. A large number of random samples were thus created for each AAF to estimate variances. The derivation of the distributions of the different parameters is presented as well as sensitivity analyses which give an estimation of the number of samples required to determine the variance with predetermined precision, and to determine which parameter had the most impact on the variance of the AAFs.Results: The analysis of the five Asian regions showed that 150 000 samples gave a sufficiently accurate estimation of the 95% confidence intervals for each disease. The relative risk functions accounted for most of the variance in the majority of cases.Conclusions: Within reasonable computation time, the method yielded very accurate values for variances of AAFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'activation des mastocytes se produit dans plusieurs conditions pathologiques et est principalement observée chez des patients développant une réaction anaphylactique. Dans la pratique clinique, la mesure de l'histamine et de ses métabolites dans le plasma et dans l'urine du patient peut être effectuée et montre parfois des résultats aussi précis que la mesure de la beta-tryptase dans le sang lorsqu'il est nécessaire de confirmer une activation mastocytaire. En revanche, la mesure de la beta tryptase dans l'urine dans un but diagnostic n'a que rarement été effectuée sur des personnes vivantes et a montré des résultats contradictoires. Dans le domaine de la médecine légale, la mesure de la beta-tryptase dans un but diagnostic est effectuée dans le sérum postmortem obtenu à partir de sang prélevé au niveau fémoral. Cependant, le sang peut être partiellement ou complètement indisponible dans certains cas spécifiques, dans les autopsies de nourrissons ou de corps sévèrement mutilés par exemple. Un des buts de notre étude est d'évaluer la pertinence de la mesure de la beta-tryptase dans des échantillons biologiques alternatifs, à savoir dans l'urine, l'humeur vitrée et le liquide péricardique. Pour cela nous avons sélectionné 94 cas d'autopsies comprenant 6 cas de réaction anaphylactique suite à l'administration de produits de contraste radiologique, 10 cas d'hypothermie, 10 cas d'acidocétose diabétique, 10 cas de suicide par arme à feu, 18 cas de décès consécutif à une injection d'héroïne, 10 cas de décès traumatiques, 10 cas de mort subite avec peu ou pas d'athérosclérose coronarienne, 10 cas de décès avec une athérosclérose coronarienne sévère mais sans signe d'infarctus du myocarde et 10 cas de décès consécutif à un infarctus du myocarde avec une athérosclérose coronarienne sévère. Dans tous les cas de réaction anaphylactique suite à l'administration de produit de contraste radiologique, les concentrations de beta-tryptase, mesurées dans le sérum postmortem et dans le liquide péricardique, ont montré des valeurs plus élevées que le seuil clinique de référence (11 ng/l) et le seuil postmortem de référence (45 ng/l). La concentration de beta-tryptase mesurée dans l'urine et l'humeur vitrée a montré des valeurs inférieures au seuil clinique dans tous les cas de notre étude. La mesure de la concentration de beta tryptase dans le liquide péricardique semble donc une alternative valable à la mesure dans le sérum postmortem, lorsque le sang fémoral n'est pas disponible durant l'autopsie, afin de poser un diagnostic de réaction anaphylactique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary points: - The bias introduced by random measurement error will be different depending on whether the error is in an exposure variable (risk factor) or outcome variable (disease) - Random measurement error in an exposure variable will bias the estimates of regression slope coefficients towards the null - Random measurement error in an outcome variable will instead increase the standard error of the estimates and widen the corresponding confidence intervals, making results less likely to be statistically significant - Increasing sample size will help minimise the impact of measurement error in an outcome variable but will only make estimates more precisely wrong when the error is in an exposure variable

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10-12% increase in the number of IR examinations every year (UNSCEAR, 2010). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed.The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncertainty quantification of petroleum reservoir models is one of the present challenges, which is usually approached with a wide range of geostatistical tools linked with statistical optimisation or/and inference algorithms. The paper considers a data driven approach in modelling uncertainty in spatial predictions. Proposed semi-supervised Support Vector Regression (SVR) model has demonstrated its capability to represent realistic features and describe stochastic variability and non-uniqueness of spatial properties. It is able to capture and preserve key spatial dependencies such as connectivity, which is often difficult to achieve with two-point geostatistical models. Semi-supervised SVR is designed to integrate various kinds of conditioning data and learn dependences from them. A stochastic semi-supervised SVR model is integrated into a Bayesian framework to quantify uncertainty with multiple models fitted to dynamic observations. The developed approach is illustrated with a reservoir case study. The resulting probabilistic production forecasts are described by uncertainty envelopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relationships between porosity and hydraulic conductivity tend to be strongly scale- and site-dependent and are thus very difficult to establish. As a result, hydraulic conductivity distributions inferred from geophysically derived porosity models must be calibrated using some measurement of aquifer response. This type of calibration is potentially very valuable as it may allow for transport predictions within the considered hydrological unit at locations where only geophysical measurements are available, thus reducing the number of well tests required and thereby the costs of management and remediation. Here, we explore this concept through a series of numerical experiments. Considering the case of porosity characterization in saturated heterogeneous aquifers using crosshole ground-penetrating radar and borehole porosity log data, we use tracer test measurements to calibrate a relationship between porosity and hydraulic conductivity that allows the best prediction of the observed hydrological behavior. To examine the validity and effectiveness of the obtained relationship, we examine its performance at alternate locations not used in the calibration procedure. Our results indicate that this methodology allows us to obtain remarkably reliable hydrological predictions throughout the considered hydrological unit based on the geophysical data only. This was also found to be the case when significant uncertainty was considered in the underlying relationship between porosity and hydraulic conductivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strong platelet activation results in a redistribution of negatively charged phospholipids from the cytosolic to the outer leaflet of the cellular membrane. Annexin V has a high affinity to negatively charged phospholipids and can be used to identify procoagulant platelets. Formaldehyde fixation can cause factitious Annexin V binding. Our aim was to evaluate a method for fixing platelets avoiding additional Annexin V binding. We induced expression of negatively charged phospholipids on the surface of a fraction of platelets by combined activation with convulxin and thrombin in the presence of Annexin V-fluorescein isothiocyanate and calcium. Aliquots of resting and activated platelets were fixed with a low concentration, calcium-free formaldehyde solution. Both native platelets and fixed platelets were analyzed by flow cytometry immediately and after a 24-h storage at 4°C. We observed that the percentage of Annexin V positive resting platelets ranged from 1.5 to 9.3% for the native samples and from 0.4 to 12.8% for the fixed samples (P=0.706, paired t-test). The amount of Annexin V positive convulxin/thrombin activated platelets varied from 12.9 to 35.4% without fixation and from 15.3 to 36.3% after formalin fixation (P=0.450). After a 24-h storage at 4°C, Annexin V positive platelets significantly increased both in the resting and in the convulxin/thrombin activated samples of native platelets (both P<0.001), while results for formalin fixed platelets did not differ from baseline values (P=0.318 for resting fixed platelets; P=0.673 for activated fixed platelets). We conclude that platelet fixation with a low concentration, calcium-free formaldehyde solution does not alter the proportion of Annexin V positive platelets. This method can be used to investigate properties of procoagulant platelets by multicolor flow-cytometric analysis requiring fixation steps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.