46 resultados para Altman, Ida


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Much biomedical research is observational. The reporting of such research is often inadequate, which hampers the assessment of its strengths and weaknesses and of a study's generalisability. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Initiative developed recommendations on what should be included in an accurate and complete report of an observational study. We defined the scope of the recommendations to cover three main study designs: cohort, case-control, and cross-sectional studies. We convened a 2-day workshop in September 2004, with methodologists, researchers, and journal editors to draft a checklist of items. This list was subsequently revised during several meetings of the coordinating group and in e-mail discussions with the larger group of STROBE contributors, taking into account empirical evidence and methodological considerations. The workshop and the subsequent iterative process of consultation and revision resulted in a checklist of 22 items (the STROBE Statement) that relate to the title, abstract, introduction, methods, results, and discussion sections of articles. 18 items are common to all three study designs and four are specific for cohort, case-control, or cross-sectional studies. A detailed Explanation and Elaboration document is published separately and is freely available on the Web sites of PLoS Medicine, Annals of Internal Medicine, and Epidemiology. We hope that the STROBE Statement will contribute to improving the quality of reporting of observational studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Colonoscopy is usually proposed for the evaluation of lower gastrointestinal blood loss (hematochezia) or iron deficiency anemia (IDA). Clinical practice guidelines support this approach but formal evidence is lacking. Real clinical scenarios made available on the web would be of great help in decision-making in clinical practice as to whether colonoscopy is appropriate for a given patient. Method: A multidisciplinary multinational expert panel (EPAGE II) developed appropriateness criteria based on best published evidence (systematic reviews, clinical trials, guidelines) and experts' judgement. Using the explicit RAND Appropriateness Method (3 round of experts' votes and a panel meeting) 102 clinical scenarios were judged inappropriate, uncertain, appropriate, or necessary. Results: In IDA, colonoscopy was appropriate in patients >50 years and necessary in the presence of lower abdominal symptoms. In both men and women aged <50 years, colonoscopy was appropriate if prior sigmoidoscopy and/or gastroscopy did not explain the IDA, and necessary if lower gastrointestinal symptoms were present. In women <50 years with a potential gynecological cause, additional lower gastrointestinal symptoms rendered colonoscopy appropriate. In patients >50 years with hematochezia, colonoscopy was always appropriate and mostly necessary, except if a prior colonoscopy was normal within the previous 5 years. Under age 50 years, the presence of any risk factor for colorectal cancer (CRC) and no previous normal colonoscopy (within the last 5 years) made this procedure appropriate and necessary. Conclusion: Colonoscopy is appropriate and even necessary for many indications related to iron deficiency anemia or hematochezia, in particular in patients aged >50 years. The main factors influencing appropriateness are age, results of prior investigations (sigmoidoscopy, gastroscopy, previous colonoscopy), CRC risk and sex. EPAGE II appropriateness criteria are available on www.epage.ch

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: To summarize the published literature on assessment of appropriateness of colonoscopy for the investigation of iron-deficiency anemia (IDA) and hematochezia, and report appropriateness criteria developed by an expert panel, the 2008 European Panel on the Appropriateness of Gastrointestinal Endoscopy, EPAGE II. METHODS: A systematic search of guidelines, systematic reviews and primary studies regarding the evaluation and management of IDA and hematochezia was performed. The RAND/UCLA Appropriateness Method was applied to develop appropriateness criteria for colonoscopy for these conditions. RESULTS: IDA occurs in 2 %-5 % of adult men and postmenopausal women. Examination of both the upper and lower gastrointestinal tract is recommended in patients with iron deficiency. Colonoscopy for IDA yields one colorectal cancer (CRC) in every 9-13 colonoscopies. Hematochezia is a well-recognized alarm symptom and such patients are likely to be referred for colonoscopy. Colonoscopy is unanimously recommended in patients aged > or = 50. Diverticulosis, vascular ectasias, and ischemic colitis are common causes of acute lower gastrointestinal bleeding (LGIB); CRC is found in 0.2 %-11 % of the colonoscopies performed for LGIB. Most patients with scant hematochezia have an anorectal or a distal source of bleeding. The expert panel considered most clinical indications for colonoscopy as appropriate in the presence of IDA (58 %) or hematochezia (83 %). CONCLUSION: Despite the limitations of the published studies, guidelines unanimously recommend colonoscopy for the investigation of IDA and hematochezia in patients aged > or = 50 years. These indications were also considered appropriate by EPAGE II, as were indications in patients at low risk for CRC with no obvious cause of bleeding found during adequate previous investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The increase of apparent diffusion coefficient (ADC) in treated hepatic malignancies compared to pre-therapeutic values has been interpreted as treatment success; however, the variability of ADC measurements remains unknown. Furthermore, ADC has been usually measured in the whole lesion, while measurements should be probably centered on the area with the most restricted diffusion (MRDA) as it represents potential tumoral residue. Our objective was to compare the inter/intraobserver variability of ADC measurements in the whole lesion and in MRDA. Material and methods: Forty patients previously treated with chemoembolization or radiofrequency were evaluated (20 on 1.5T and 20 on 3.0T). After consensual agreement on the best ADC image, two readers measured the ADC values using separate regions of interest that included the whole lesion and the whole MRDA without exceeding their borders. The same measurements were repeated two weeks later. Spearman test and the Bland-Altman method were used. Results: Interobserver correlation in ADC measurements in the whole lesion and MRDA was as follows: 0.962 and 0.884. Intraobserver correlation was, respectively, 0.992 and 0.979. Interobserver limits of variability (mm2/sec*10-3) were between -0.25/+0.28 in the whole lesion and between -0.51/+0.46 in MRDA. Intraobserver limits of variability were, respectively: -0.25/+0.24 and -0.43/+0.47. Conclusion: We observed a good inter/intraobserver correlation in ADC measurements. Nevertheless, a limited variability does exist, and it should be considered when interpreting ADC values of hepatic malignancies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soluble MHC-peptide complexes, commonly known as tetramers, allow the detection and isolation of antigen-specific T cells. Although other types of soluble MHC-peptide complexes have been introduced, the most commonly used MHC class I staining reagents are those originally described by Altman and Davis. As these reagents have become an essential tool for T cell analysis, it is important to have a large repertoire of such reagents to cover a broad range of applications in cancer research and clinical trials. Our tetramer collection currently comprises 228 human and 60 mouse tetramers and new reagents are continuously being added. For the MHC II tetramers, the list currently contains 21 human (HLA-DR, DQ and DP) and 5 mouse (I-A(b)) tetramers. Quantitative enumeration of antigen-specific T cells by tetramer staining, especially at low frequencies, critically depends on the quality of the tetramers and on the staining procedures. For conclusive longitudinal monitoring, standardized reagents and analysis protocols need to be used. This is especially true for the monitoring of antigen-specific CD4+ T cells, as there are large variations in the quality of MHC II tetramers and staining conditions. This commentary provides an overview of our tetramer collection and indications on how tetramers should be used to obtain optimal results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. METHODS: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. RESULTS: There was a good agreement between virtual and real volumes for brain (mean difference: -0.03% (-13.6 to +7.1)), liver (+8.3% (-9.6 to +26.2)) and lungs (+5.5% (-26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). CONCLUSIONS: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Several software packages (SWP) and models have been released for quantification of myocardial perfusion (MP). Although they all are validated against something, the question remains how well their values agree. The present analysis focused on cross-comparison of three SWP for MP quantification of 13N-ammonia PET studies. Materials & Methods. 48 rest and stress MP 13N-ammonia PET studies of hypertrophic cardiomyopathy (HCM) patients (Sciagrà et al., 2009) were analysed with three SW packages - Carimas, PMOD, and FlowQuant - by three observers blinded to the results of each other. All SWP implement the one-tissue-compartment model (1TCM, DeGrado et al. 1996), and first two - the two-tissue-compartment model (2TCM, Hutchins et al. 1990) as well. Linear mixed model for the repeated measures was fitted to the data. Where appropriate we used Bland-Altman plots as well. The reproducibility was assessed on global, regional and segmental levels. Intraclass correlation coefficients (ICC), differences between the SWPs and between models were obtained. ICC≥0.75 indicated excellent reproducibility, 0.4≤ICC<0.75 indicated fair to good reproducibility, ICC<0.4 - poor reproducibility (Rosner, 2010). Results. When 1TCM MP values were compared, the SW agreement on global and regional levels was excellent, except for Carimas vs. PMOD at RCA: ICC=0.715 and for PMOD vs. FlowQuant at LCX:ICC=0.745 which were good. In segmental analysis in five segments: 7,12,13, 16, and 17 the agreement between all SWP was excellent; in the remaining 12 segments the agreement varied between the compared SWP. Carimas showed excellent agreement with FlowQuant in 13 segments and good in four - 1, 5, 6, 11: 0.687≤ICCs≤0.73; Carimas had excellent agreement with PMOD in 11 segments, good in five_4, 9, 10, 14, 15: 0.682≤ICCs≤0.737, and poor in segment 3: ICC=0.341. PMOD had excellent agreement with FlowQuant in eight segments and substantial-to-good in nine_1, 2, 3, 5, 6,8-11: 0.585≤ICCs≤0.738. Agreement between Carimas and PMOD for 2TCM was good at a global level: ICC=0.745, excellent at LCX (0.780) and RCA (0.774), good at LAD (0.662); agreement was excellent for ten segments, fair-to-substantial for segments 2, 3, 8, 14, 15 (0.431≤ICCs≤0.681), poor for segments 4 (0.384) and 17 (0.278). Conclusions. The three SWP used by different operators to analyse 13N-ammonia PET MP studies provide results that agree well at a global level, regional levels, and mostly well even at a segmental level. Agreement is better for 1TCM. Poor agreement at segments 4 and 17 for 2TCM needs further clarification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obesity is heritable and predisposes to many diseases. To understand the genetic basis of obesity better, here we conduct a genome-wide association study and Metabochip meta-analysis of body mass index (BMI), a measure commonly used to define obesity and assess adiposity, in up to 339,224 individuals. This analysis identifies 97 BMI-associated loci (P < 5 × 10(-8)), 56 of which are novel. Five loci demonstrate clear evidence of several independent association signals, and many loci have significant effects on other metabolic phenotypes. The 97 loci account for ∼2.7% of BMI variation, and genome-wide estimates suggest that common variation accounts for >20% of BMI variation. Pathway analyses provide strong support for a role of the central nervous system in obesity susceptibility and implicate new genes and pathways, including those related to synaptic function, glutamate signalling, insulin secretion/action, energy metabolism, lipid biology and adipogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Selective publication of studies, which is commonly called publication bias, is widely recognized. Over the years a new nomenclature for other types of bias related to non-publication or distortion related to the dissemination of research findings has been developed. However, several of these different biases are often still summarized by the term 'publication bias'. METHODS/DESIGN: As part of the OPEN Project (To Overcome failure to Publish nEgative fiNdings) we will conduct a systematic review with the following objectives:- To systematically review highly cited articles that focus on non-publication of studies and to present the various definitions of biases related to the dissemination of research findings contained in the articles identified.- To develop and discuss a new framework on nomenclature of various aspects of distortion in the dissemination process that leads to public availability of research findings in an international group of experts in the context of the OPEN Project.We will systematically search Web of Knowledge for highly cited articles that provide a definition of biases related to the dissemination of research findings. A specifically designed data extraction form will be developed and pilot-tested. Working in teams of two, we will independently extract relevant information from each eligible article.For the development of a new framework we will construct an initial table listing different levels and different hazards en route to making research findings public. An international group of experts will iteratively review the table and reflect on its content until no new insights emerge and consensus has been reached. DISCUSSION: Results are expected to be publicly available in mid-2013. This systematic review together with the results of other systematic reviews of the OPEN project will serve as a basis for the development of future policies and guidelines regarding the assessment and prevention of publication bias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: There is no "gold standard" for assessing disease activity in patients with eosinophilic esophagitis (EoE). We aimed to compare physicians' judgment of EoE activity with patients' judgment of symptom severity. We also aimed to examine the relative contribution of symptoms as well as endoscopic and histologic findings in shaping physicians' judgment of EoE activity. METHODS: Six gastroenterologists (all EoE experts) assessed EoE-associated symptoms in adult patients. Patients completed a symptom instrument and provided global assessment of EoE symptom severity (PatGA) (Likert scale: 0 (inactive) to 10 (most active)). Following esophagogastroduodenoscopy with biopsy sampling, gastroenterologists provided a global assessment of EoE activity (PhysGA) (Likert scale from 0 to 10) based on patient history and endoscopic and histologic findings. Linear regression and analysis of variance was used to quantify the extent to which variations in severity of EoE symptoms and endoscopic and histologic findings explain variations in PhysGA. RESULTS: A total of 149 EoE patients were prospectively included (71.8% male, median age at inclusion 38 years, 71.8% with concomitant allergies). A moderate positive correlation between PhysGA and PatGA (rho=0.442, P<0.001) was observed and the mean difference in the Bland-Altman plot was 1.77. Variations in severity of endoscopic findings, symptoms, and histologic findings alone explained 53%, 49%, and 30%, of the variability in PhysGA, respectively. Together, these findings explained 75% of variability in PhysGA. CONCLUSIONS: Gastroenterologists rate EoE activity mainly on the basis of endoscopic findings and symptoms and, to a lesser extent, on histologic findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the Arabidopsis thaliana genome, over 1000 putative genes encoding small, presumably secreted, signalling peptides can be recognized. However, a major obstacle in identifying the function of genes encoding small signalling peptides is the limited number of available loss-of-function mutants. To overcome this, a promising new tool, antagonistic peptide technology, was recently developed. Here, this antagonistic peptide technology was tested on selected CLE peptides and the related IDA peptide and its usefulness in the context of studies of peptide function discussed. Based on the analyses, it was concluded that the antagonistic peptide approach is not the ultimate means to overcome redundancy or lack of loss-of-function lines. However, information collected using antagonistic peptide approaches (in the broad sense) can be very useful, but these approaches do not work in all cases and require a deep insight on the interaction between the ligand and its receptor to be successful. This, as well as peptide ligand structure considerations, should be taken into account before ordering a wide range of synthetic peptide variants and/or generating transgenic plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to review highly cited articles that focus on non-publication of studies, and to develop a consistent and comprehensive approach to defining (non-) dissemination of research findings. SETTING: We performed a scoping review of definitions of the term 'publication bias' in highly cited publications. PARTICIPANTS: Ideas and experiences of a core group of authors were collected in a draft document, which was complemented by the findings from our literature search. INTERVENTIONS: The draft document including findings from the literature search was circulated to an international group of experts and revised until no additional ideas emerged and consensus was reached. PRIMARY OUTCOMES: We propose a new approach to the comprehensive conceptualisation of (non-) dissemination of research. SECONDARY OUTCOMES: Our 'What, Who and Why?' approach includes issues that need to be considered when disseminating research findings (What?), the different players who should assume responsibility during the various stages of conducting a clinical trial and disseminating clinical trial documents (Who?), and motivations that might lead the various players to disseminate findings selectively, thereby introducing bias in the dissemination process (Why?). CONCLUSIONS: Our comprehensive framework of (non-) dissemination of research findings, based on the results of a scoping literature search and expert consensus will facilitate the development of future policies and guidelines regarding the multifaceted issue of selective publication, historically referred to as 'publication bias'.