Assessment of glenoid inclination on routine clinical radiographs and computed tomography examinations of the shoulder.
Data(s) |
2012
|
---|---|
Resumo |
BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability. |
Identificador |
https://serval.unil.ch/?id=serval:BIB_FC490BFFAFD7 isbn:1532-6500 (Electronic) pmid:22036540 doi:10.1016/j.jse.2011.07.010 isiid:000307805600021 |
Idioma(s) |
en |
Fonte |
Journal of Shoulder and Elbow Surgery, vol. 21, no. 8, pp. 1096-1103 |
Palavras-Chave | #Biomechanics; Cohort Studies; Female; Glenoid Cavity/physiology; Glenoid Cavity/radiography; Humans; Imaging, Three-Dimensional; Male; Models, Theoretical; Observer Variation; Range of Motion, Articular/physiology; Reference Values; Reproducibility of Results; Rotation; Scapula/physiology; Scapula/radiography; Shoulder Joint/physiology; Shoulder Joint/radiography; Tomography, X-Ray Computed/methods |
Tipo |
info:eu-repo/semantics/article article |