380 resultados para Body suport device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: More than two billion people worldwide are deficient in key micronutrients. Single micronutrients have been used at high doses to prevent and treat dietary insufficiencies. Yet the impact of combinations of micronutrients in small doses aiming to improve lipid disorders and the corresponding metabolic pathways remains incompletely understood. Thus, we investigated whether a combination of micronutrients would reduce fat accumulation and atherosclerosis in mice. METHODS AND RESULTS: Lipoprotein receptor-null mice fed with an original combination of micronutrients incorporated into the daily chow showed reduced weight gain, body fat, plasma triglycerides, and increased oxygen consumption. These effects were achieved through enhanced lipid utilization and reduced lipid accumulation in metabolic organs and were mediated, in part, by the nuclear receptor PPARα. Moreover, the micronutrients partially prevented atherogenesis when administered early in life to apolipoprotein E-null mice. When the micronutrient treatment was started before conception, the anti-atherosclerotic effect was stronger in the progeny. This finding correlated with decreased post-prandial triglyceridaemia and vascular inflammation, two major atherogenic factors. CONCLUSION: Our data indicate beneficial effects of a combination of micronutritients on body weight gain, hypertriglyceridaemia, liver steatosis, and atherosclerosis in mice, and thus our findings suggest a novel cost-effective combinatorial micronutrient-based strategy worthy of being tested in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : La prise en charge des patients critiques nécessite dans la majorité des situations l'obtention rapide d'un accès vasculaire, afin d'administrer des médicaments, des solutés de remplissage, ou des produits sanguins. La mise en place d'un accès vasculaire peut s'avérer difficile chez ces patients. En cas d'échec de pose d'une voie veineuse périphérique, des abords vasculaires alternatifs existent. Il s'agit essentiellement de la pose d'une voie veineuse centrale, la réalisation d'une dénudation veineuse, ou la pose d'une voie intra-osseuse. Depuis le développement de dispositifs d'insertion « semi-automatique » à la fin des années 90, la voie intra-osseuse, traditionnellement réservée aux cas pédiatriques, est de plus en plus fréquemment utilisée chez les patients adultes. Le Service des Urgences du CHUV a introduit en 2009 les dispositifs d'insertion d'aiguilles intra-osseuses de type EZ-IO® (perceuse électrique), en salle de réanimation des urgences vitales (déchoquage), ainsi qu'au sein du secteur préhospitalier pour les interventions du SMUR de Lausanne et de l'hélicoptère REGA de la base de Lausanne. Par cette étude, nous voulions mettre en évidence les aspects épidémiologiques des patients ayant dû être perfusés par cet abord dans un contexte préhospitalier, ainsi que les circonstances cliniques ayant justifié un tel usage, le taux de succès, les éventuelles complications, les médicaments perfusés et la mortalité des patients ayant bénéficié de ce dispositif. Méthode: Chaque patient ayant bénéficié de la mise en place d'une voie intra-osseuse par EZ-IO® du 1er janvier 2009 au 31 décembre 2011 a été inclus. Les données récoltées étaient l'âge, le sexe, l'indication à la mise en place de l'intra-osseuse, la localisation, le taux de succès, les médicaments et fluides administrés, les complications, la mortalité à 48 heures et à la sortie de l'hôpital. Tous les articles mentionnant l'utilisation de ΙΈΖ-ΙΟ® dans des situations cliniques ont également été analysés par une revue de littérature structurée exhaustive, afin de comparer nos résultats avec les données de la littérature. Résultats : Cinquante-huit patients, représentant 60 intra-osseuses EZ-IO®, ont été inclus. Leur âge moyen (47 ans), le taux de succès (90%), les indications, la localisation de l'aiguille (98% au niveau du tibia proximal) et le taux de complications (0%) correspondent aux valeurs trouvées dans la littérature. Le taux de survie de nos patients est de 38% à 48 heures et de 29% à la sortie de l'hôpital. De nombreux médicaments ou solutés de perfusion ont été administrés; l'adrénaline restant le médicament le plus fréquemment administré par cette voie. Dans 7 cas, les patients ont bénéficié d'une induction d'anesthésie par voie intra-osseuse. La revue de littérature a permis de compiler 30 études distinctes, représentant un total de 1603 accès vasculaires de type EZ-IO®. Conclusion : La voie intra-osseuse s'avère fiable et rapide pour obtenir un accès vasculaire, avec un taux de complications très faible et permet l'administration d'un grand nombre de substances. D'autres études sont nécessaires pour évaluer l'impact de la voie intra osseuse, notamment en termes de mortalité, de complications tardives, ainsi que d'analyse coût/bénéfice de ce matériel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two studies were performed to investigate the association between body fat mass and fat oxidation. The first, a cross-sectional study of 106 obese women maintaining stable body weight, showed that these two variables were significantly correlated (r = 0.56, P less than 0.001) and the regression coefficient indicated that a 10-kg change in fat mass corresponded to a change in fat oxidation of approximately 20 g/d. The second, a prospective study, validated this estimate and quantifies the long-term adaptations in fat oxidation resulting from body fat loss. Twenty-four moderately obese women were studied under controlled dietary conditions at stable weight before and after mean weight and fat losses of 12.7 and 9.8 kg, respectively. The reduction in fat oxidation was identical to that predicted by the above regression. We conclude that changes in fat mass significantly affect fat oxidation and that this process may contribute to the long-term regulation of fat and energy balance in obese individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity is heritable and predisposes to many diseases. To understand the genetic basis of obesity better, here we conduct a genome-wide association study and Metabochip meta-analysis of body mass index (BMI), a measure commonly used to define obesity and assess adiposity, in up to 339,224 individuals. This analysis identifies 97 BMI-associated loci (P < 5 × 10(-8)), 56 of which are novel. Five loci demonstrate clear evidence of several independent association signals, and many loci have significant effects on other metabolic phenotypes. The 97 loci account for ∼2.7% of BMI variation, and genome-wide estimates suggest that common variation accounts for >20% of BMI variation. Pathway analyses provide strong support for a role of the central nervous system in obesity susceptibility and implicate new genes and pathways, including those related to synaptic function, glutamate signalling, insulin secretion/action, energy metabolism, lipid biology and adipogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutrition assessment is important during chronic respiratory insufficiency to evaluate the level of malnutrition or obesity and should include body composition measurements. The appreciation of fat-free and fat reserves in patients with chronic respiratory insufficiency can aid in designing an adapted nutritional support, e.g., nutritional support in malnutrition and food restriction in obesity. The purpose of the present study was to cross-validate fat-free and fat mass obtained by various bioelectric impedance (BIA) formulas with the fat-free and fat mass measured by dual-energy X-ray absorptiometry (DXA) and determine the formulas that are best suited to predict the fat-free and fat mass for a group of patients with severe chronic respiratory insufficiency. Seventy-five patients (15 women and 60 men) with chronic obstructive and restrictive respiratory insufficiency aged 45-86 y were included in this study. Body composition was calculated according to 13 different BIA formulas for women and 12 for men and compared with DXA. Because of the variability, calculated as 2 standard deviations, of +/- 5.0 kg fat-free mass for women and +/- 6.4 kg for men for the best predictive formula, the use of the various existing BIA formulas was considered not clinically relevant. Therefore disease-specific formulas for patients with chronic respiratory insufficiency should be developed to improve the prediction of fat-free and fat mass by BIA in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to study whole body protein synthesis and breakdown, as well as energy metabolism, in very low birth weight premature infants (less than 1500 g) during their rapid growth phase. Ten very low birth weight infants were studied during their first and second months of life. They received a mean energy intake of 114 kcal/kg X day and 3 g protein/kg X day as breast milk or milk formula. The average weight gain was 15 g/kg X day. The apparent energy digestibility was 88%, i.e. 99 kcal/kg X day. Their resting postprandial energy expenditure was 58 kcal/kg X day, indicating that 41 kcal/kg X day was retained. The apparent protein digestibility was 89%, i.e. 2.65 g/kg X day. Their rate of protein oxidation was 0.88 g/kg X day so that protein retention was 1.76 g/kg X day. There was a linear relationship between N retention and N intake (r = 0.78, p less than 0.001). The slope of the regression line indicates a net efficiency of N utilization of 67%. Estimates of body composition from the energy balance, coupled with N balance method, showed that 25% of the gain was fat and 75% was lean tissue. Whole body protein synthesis and breakdown were determined using repeated oral administration of 15N glycine for 60-72 h, and 15N enrichment in urinary urea was measured. Protein synthesis averaged 11.2 g/kg X day and protein breakdown 9.4 g/kg X day. Muscular protein breakdown, as estimated by 3-methylhistidine excretion, contributed to 12% of the total protein breakdown.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We examined one's own body image perception and its association with reported weight-related behavior among adolescents of a rapidly developing country in the African region. Methods: We conducted a school-based survey of 1432 students aged 11-17 years in the Seychelles. Weight and height were measured, and thinness, normal weight and overweight were assessed along standard criteria. A self-administered and anonymous questionnaire was administered. Perception of body image was assessed using both a closed-ended question (CEQ) and the Stunkard's pictorial silhouettes (SPS). Finally, a question assessed voluntary attempts to change weight. Results: Overall, 14.1% of the students were thin, 63.9% were normal-weight, and 22.0% were overweight or obese. There was fair agreement between actual weight status and self-perceived body image based on either CEQ or SPS. However, a substantial proportion of the overweight students did not consider themselves as overweight (SPS: 24%, CEQ: 34%) and, inversely, a substantial proportion of the normal-weight students considered themselves as too thin (SPS: 29%, CEQ: 15%). Among the overweight students, an adequate attempt to lose weight was reported more often by boys and girls who perceived themselves as overweight vs. not overweight (72-88% vs. 40-71%, p <0.05 for most comparisons). Among the normal-weight students, an inadequate attempt to gain weight was reported more often by boys and girls who perceived themselves as thin vs. not thin (27-68% vs. 11-19%, p <0.05). Girls had leaner own body ideals than boys. Conclusions: We found that substantial proportions of overweight students did not perceive themselves as overweight and/or did not want to lose weight and, inversely, that many normalweight students perceived themselves as too thin and/or wanted to gain weight: this points to forces that can drive the upwards overweight trends. Appropriate perception of one's weight was associated with adequate weight-control behavior, although not strongly, emphasizing that appropriate weight perception is only one of several factors driving adequate weight-related behavior. These findings emphasize the need to address appropriate perception of one's own weight and adequate weight-related behavior in adolescents for both individual and community weight-related interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Les études épidémiologiques indiquent que la restriction intra-utérine confère un risque accru de développement de diabète de type 2 au cours de la vie. Certaines études ont documenté la présence d'une résistance à l'insuline chez les jeunes adultes ou les adolescents nés petits pour l'âge gestationnel. Comme la plupart des études ont impliqués des individus post-pubères et comme la puberté influence de manière marquée le métabolisme énergétique, nous avons évalué le devenir du glucose administré oralement dans un groupe incluant essentiellement des enfants pré-pubères ou en début de puberté avec restriction intra-utérine, et chez des enfants matchés pour l'âge et pour le poids. Tous les enfants ont eu une évaluation de leur composition corporelle par mesure des plis cutanés. Ils ont ensuite été étudiés dans des conditions standardisées et ont reçu 4 charges consécutives orales de glucose à raison de 180 mg/kg de poids corporel jusqu'à atteindre un état d'équilibre relatif. La dépense énergétique et l'oxydation des substrats ont été évaluées durant la quatrième heure par calorimétrie indirecte. Comparativement avec les enfants matchés pour l'âge et le poids, les enfants nés petits pour l'âge gestationnel avaient une plus petite stature. Leur dépense énergétique n'était pas significativement abaissée, mais leur oxydation du glucose était plus basse. Ces résultats indiquent que des altérations métaboliques sont présentes précocement chez les enfants nés petits pour l'âge gestationnel, et qu'elles sont possiblement reliées à des altérations de la composition corporelle. Abstract: Epidemiological studies indicate that intrauterine growth restriction confers an increased risk of developing type 2 diabetes mellitus in subsequent life. Several studies have further documented the presence of insulin resistance in young adults or adolescent children born small for gestational age. Since most studies addressed postpubertal individuals, and since puberty markedly affects energy metabolism, we evaluated the disposal of oral glucose in a group including mainly prepubertal and early pubertal children with intrauterine growth restriction and in healthy age- and weight-matched control children. All children had an evaluation of their body composition by skinfold thickness measurements. They were then studied in standardized conditions and received 4 consecutive hourly loads of 180 mg glucose/kg body weight to reach a near steady state. Energy expenditure and substrate oxidation were evaluated during the fourth hour by indirect calorimetry. Compared to both age- and weight-matched children, children born small for gestational age had lower stature. Their energy expenditure was not significantly decreased, but they had lower glucose oxidation rates. These results indicate that metabolic alterations are present early in children born small for gestational age, and are possibly related to alterations of body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La réponse métabolique de l'obèse apparemment « sainen situation d'agression aiguë (polytraumatisés, traumatisés crâniens, patients chirurgicaux, grands brûlés, opérations électives) ne se distingue pas ou peu de celle de l'individu non-obèse. Cependant, les complications médicales liées à l'agression (insuffisances respiratoire et cardiaque, bronchopneumonie, infections de plaies, thrombophlébites et embolies) demeurent plus importantes chez l'obèse morbide que chez l'individu de poids normal. Grâce à l'inflation de ses réserves énergétiques, l'obèse apparemment sain est avantagé, par rapport au sujet mince, au cours d'une agression nutritionnelle chronique telle que le jeûne prolongé. Le facteur fonctionnel limitant la survie dépend avant tout de la composition corporelle initiale et du degré d'adaptation métabolique (et comportementale) en particulier du degré de conservation de la masse maigre par rapport à la masse grasse. La mobilisation accrue de la masse grasse associée à la perte de poids chez l'obèse (par rapport à son homologue non-obèse) est favorable à une prolongation de la vie, car, en brûlant davantage de graisse corporelle, la part des protéines corporelles endogènes utilisée à des fins énergétiques est plus faible. Il s'ensuit chez l'obèse qu'un niveau de masse maigre critique pour la survie n'est atteint qu'après une réduction très marquée de ses réserves énergétiques. En revanche, le sujet mince perd davantage de masse maigre lors de l'amaigrissement et, par conséquent, son métabolisme de repos diminuera plus rapidement que celui du sujet obèse. Cela peut constituer un avantage énergétique évident en termes d'économie d'énergie consécutive à l'adaptation métabolique, mais un inconvénient majeur quant à la durée de la survie. The metabolic response of « apparently healthyobese individuals following acute injury (multiple trauma, head injury and surgical patients, extended burns, elective surgery) is not dramatically different from that of a non-obese individuals. However, the medical complications following the injury (respiratory and cardiac insufficiency, broncho-pneumonia, infections of wounds, trombophlebitis and embolism) are more prevalent in morbid obese patients than in individuals of normal body weight. Because of a large increase in their individuals energy store, "apparently healthy" obese individuals have an advantage over very lean subjects when exposed to a chronic nutritional aggression such as total fasting. The functional limiting factor for survival depends primarily on initial body composition and the magnitude of metabolic adaptation (including behavioral adaptation). The key factor is the extent to which the fat-free mass is maintained (versus to the fat mass) during weight loss. The increased proportion of body fat mobilized during weight loss in obese patients, compared with their non-obese counterparts, favors prolonged survival, because more adipose tissue is burned off, the fraction of body protein endogenously utilized for energy purpose individuals, is smaller. This implies that obese individuals do not reach a fat-free mass "critical" for their survival until their energy stores reach very low values. In contrast, lean subject tend to lose more fat-free mass during weight loss than obese subjects and, as a result, their energy expenditure drops more rapidly. This may offer a potential advantage in terms of energy economy (more energy saving) but a major disadvantage in terms of duration of survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proper and rapid diagnosis of orthopedic device-related infection is important for successful treatment. Sonication has been shown to improve the diagnostic performance. We hypothesized that the combination of sonication with a novel method called microcalorimetry will further improve and accelerate the diagnosis of implant infection. We prospectively included 39 consecutive patients (mean age 59 years, 62% males) at our institution from whom 29 orthopedic prostheses and 10 osteosynthesis material were explanted. The explanted device was sonicated. The resulting sonication fluid was analyzed using microcalorimetry. Using standardized criteria to define orthopedic device-related infection, 12 cases (31%) were defined as infected. In all, positive periprosthetic tissue cultures were found. The sensitivity and specificity of microcalorimetry of sonication fluid were 100% and 97%, respectively. Mean time to detection, defined as time to reach a rising heat flow signal of 20 µW measured after equilibiration needed to get accurate measurement, was 10.9 h. In summary, microcalorimetry of sonication fluid is a reliable and a fast method in detecting the presence of microorganisms in orthopedic device-related infection. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1700-1703, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common variants at only two loci, FTO and MC4R, have been reproducibly associated with body mass index (BMI) in humans. To identify additional loci, we conducted meta-analysis of 15 genome-wide association studies for BMI (n > 32,000) and followed up top signals in 14 additional cohorts (n > 59,000). We strongly confirm FTO and MC4R and identify six additional loci (P < 5 x 10(-8)): TMEM18, KCTD15, GNPDA2, SH2B1, MTCH2 and NEGR1 (where a 45-kb deletion polymorphism is a candidate causal variant). Several of the likely causal genes are highly expressed or known to act in the central nervous system (CNS), emphasizing, as in rare monogenic forms of obesity, the role of the CNS in predisposition to obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi ventricular external assist device that reproduces the physiological heart muscle movement completely avoiding anticoagulants. Methods: The device has a carbon fibre skeleton fitting a 30-40 kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The strength of the Nitinol fibres is amplified by a pivot articulation in contact with the ventricle wall. The fibres are electrically driven and a dedicated control unit has been developed. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient has been measured with afterload ranging from 25 to 50mmHg. Results: With anafterload of 50mmHg the system has an ejection fraction (EF) of 10% on the right side and 8% on the left side. The system is able to generate a systolic ejection of 5,5 ml on the right side and 4,4 ml on the left side. With anafterload of 25mmHg the results are reduced of about 20%. The activation frequency is 80/minute resulting in a total volume displacement of 440 ml/minute on the right side and 352 ml/minute on the left side. Conclusions: The artificial muscle follows Starling's law as the ejected volume increases when afterload increases. These preliminary studies confirmed the possibility of improving the EF of a failing heart using artificial muscle for external cardiac compression. This device could be helpful in weaning CPB and/or for short-term cardio-circulatory support in paediatric population with cardiac failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the association between several cardiometabolic risk factors (CRFs) (blood pressure, LDL-cholesterol, HDL-cholesterol, triglycerides, uric acid, and glucose) in 390 young adults aged 19-20 years in Seychelles (Indian Ocean, Africa) and body mass index (BMI) measured either at the same time (cross-sectional analysis) or at the age of 12-15 years (longitudinal analysis). BMI tracked markedly between age of 12-15 and age of 19-20. BMI was strongly associated with all considered CRFs in both cross-sectional and longitudinal analyses, with some exceptions. Comparing overweight participants with those having a BMI below the age-specific median, the odds ratios for high blood pressure were 5.4/4.7 (male/female) cross-sectionally and 2.5/3.9 longitudinally (P < 0.05). Significant associations were also found for most other CRFs, with some exceptions. In linear regression analysis including both BMI at age of 12-15 and BMI at age of 19-20, only BMI at age of 19-20 remained significantly associated with most CRFs. We conclude that CRFs are predicted strongly by either current or past BMI levels in adolescents and young adults in this population. The observation that only current BMI remained associated with CRFs when including past and current levels together suggests that weight control at a later age may be effective in reducing CRFs in overweight children irrespective of past weight status.