39 resultados para SPIN-LABELED GRAMICIDIN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable isotope labels are routinely introduced into proteomes for quantification purposes. Full labeling of cells in varying biological states, followed by sample mixing, fractionation and intensive data acquisition, is used to obtain accurate large-scale quantification of total protein levels. However, biological processes often affect only a small group of proteins for a short time, resulting in changes that are difficult to detect against the total proteome background. An alternative approach could be the targeted analysis of the proteins synthesized in response to a given biological stimulus. Such proteins can be pulse-labeled with a stable isotope by metabolic incorporation of 'heavy' amino acids. In this study we investigated the specific detection and identification of labeled proteins using acquisition methods based on Precursor Ion Scans (PIS) on a triple-quadrupole ion trap mass spectrometer. PIS-based methods were set to detect unique immonium ions originating from labeled peptides. Different labels and methods were tested in standard mixtures to optimize performance. We showed that, in comparison with an untargeted analysis on the same instrument, the approach allowed a several-fold increase in the specificity of detection of labeled proteins over unlabeled ones. The technique was applied to the identification of proteins secreted by human cells into growth media containing bovine serum proteins, allowing the preferential detection of labeled cellular proteins over unlabeled bovine ones. However, compared with untargeted acquisitions on two different instruments, the PIS-based strategy showed some limitations in sensitivity. We discuss possible perspectives of the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The yeast Schizosaccharomyces pombe is frequently used as a model for studying the cell cycle. The cells are rod-shaped and divide by medial fission. The process of cell division, or cytokinesis, is controlled by a network of signaling proteins called the Septation Initiation Network (SIN); SIN proteins associate with the SPBs during nuclear division (mitosis). Some SIN proteins associate with both SPBs early in mitosis, and then display strongly asymmetric signal intensity at the SPBs in late mitosis, just before cytokinesis. This asymmetry is thought to be important for correct regulation of SIN signaling, and coordination of cytokinesis and mitosis. In order to study the dynamics of organelles or large protein complexes such as the spindle pole body (SPB), which have been labeled with a fluorescent protein tag in living cells, a number of the image analysis problems must be solved; the cell outline must be detected automatically, and the position and signal intensity associated with the structures of interest within the cell must be determined. RESULTS: We present a new 2D and 3D image analysis system that permits versatile and robust analysis of motile, fluorescently labeled structures in rod-shaped cells. We have designed an image analysis system that we have implemented as a user-friendly software package allowing the fast and robust image-analysis of large numbers of rod-shaped cells. We have developed new robust algorithms, which we combined with existing methodologies to facilitate fast and accurate analysis. Our software permits the detection and segmentation of rod-shaped cells in either static or dynamic (i.e. time lapse) multi-channel images. It enables tracking of two structures (for example SPBs) in two different image channels. For 2D or 3D static images, the locations of the structures are identified, and then intensity values are extracted together with several quantitative parameters, such as length, width, cell orientation, background fluorescence and the distance between the structures of interest. Furthermore, two kinds of kymographs of the tracked structures can be established, one representing the migration with respect to their relative position, the other representing their individual trajectories inside the cell. This software package, called "RodCellJ", allowed us to analyze a large number of S. pombe cells to understand the rules that govern SIN protein asymmetry. CONCLUSIONS: "RodCell" is freely available to the community as a package of several ImageJ plugins to simultaneously analyze the behavior of a large number of rod-shaped cells in an extensive manner. The integration of different image-processing techniques in a single package, as well as the development of novel algorithms does not only allow to speed up the analysis with respect to the usage of existing tools, but also accounts for higher accuracy. Its utility was demonstrated on both 2D and 3D static and dynamic images to study the septation initiation network of the yeast Schizosaccharomyces pombe. More generally, it can be used in any kind of biological context where fluorescent-protein labeled structures need to be analyzed in rod-shaped cells. AVAILABILITY: RodCellJ is freely available under http://bigwww.epfl.ch/algorithms.html, (after acceptance of the publication).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human cytosolic thymidine kinase (hTK1) has proven to be a suitable target for the noninvasive imaging of cancer cell proliferation using radiolabeled thymidine analogues such as [(18)F]3'-fluoro-3'-deoxythymidine ([(18)F]FLT). A thymidine analogue for single photon emission computed tomography (SPECT), which incorporates the readily available and inexpensive nuclide technetium-99m, would be of considerable practical interest. hTK1 is known to accommodate modification of the structure of the natural substrate thymidine at the positions N3 and C3' and, to a lesser extent, C5. In this work, we used the copper-catalyzed azide-alkyne cycloaddition to synthesize two series of derivatives in which thymidine is functionalized at either the C3' or N3 position with chelating systems suitable for the M(CO)(3) core (M = (99m)Tc, Re). The click chemistry approach enabled complexes with different structures and overall charges to be synthesized from a common precursor. Using this strategy, the first organometallic hTK1 substrates in which thymidine is modified at the C3' position were identified. Phosphorylation of the organometallic derivatives was measured relative to thymidine. We have shown that the influence of the overall charge of the derivatives is dependent on the position of functionalization. In the case of the C3'-functionalized derivatives, neutral and anionic substrates were most readily phosphorylated (20-28% of the value for the parent ligand thymidine), whereas for the N3-functionalized derivatives, cationic and neutral complexes were apparently better substrates for the enzyme (14-18%) than anionic derivatives (9%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion-recovery with ON-resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally-selective on-resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off-resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO-labeled stem cells in vitro and in vivo is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During one week, beginning 18 days after transplantation, nude mice bearing human colon carcinoma ranging from 115 to 943 mm3 (mean 335 mm3) were treated by repeated intravenous injections of either iodine-131-(131I) labeled intact antibodies or 131I-labeled corresponding F(ab')2 fragments of a pool of four monoclonal antibodies (MAbs) directed against distinct epitopes of carcinoembryonic antigen (CEA). Complete tumor remission was observed in 8 of 10 mice after therapy with F(ab')2 and 6 of the animals survived 10 mo in good health. In contrast, after treatment with intact MAbs, tumors relapsed in 7 of 8 mice after remission periods of 1 to 3.5 mo despite the fact that body weight loss and depression of peripheral white blood cells, symptoms of radiation toxicity, and the calculated radiation doses for liver, spleen, bone, and blood were increased or equal in these animals as compared to mice treated with F(ab')2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase of total choline in tumors has become an important biomarker in cancer diagnosis. Choline and choline metabolites can be measured in vivo and in vitro using multinuclear MRS. Recent in vivo(13)C MRS studies using labeled substrates enhanced via dynamic nuclear polarization demonstrated the tremendous potential of hyperpolarization for real-time metabolic studies. The present study demonstrates the feasibility of detecting hyperpolarized (15)N labeled choline in vivo in a rat head at 9.4 T. We furthermore report the in vitro (172 +/- 16 s) and in vivo (126 +/- 15 s) longitudinal relaxation times. We conclude that with appropriate infusion protocols it is feasible to detect hyperpolarized (15)N labeled choline in live animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical study was based on experimental results obtained in nude mice grafted with human colon carcinoma, showing that injected 131I-labeled F(ab')2 and Fab fragments from high affinity anti-carcinoembryonic antigen (CEA) monoclonal antibodies (MAb) gave markedly higher ratios of tumor to normal tissue localization than intact MAb. 31 patients with known colorectal carcinoma, including 10 primary tumors, 13 local tumor recurrences, and 21 metastatic involvements, were injected with 123I-labeled F(ab')2 (n = 14) or Fab (n = 17) fragments from MAb anti-CEA. The patients were examined by emission-computerized tomography (ECT) at 6, 24, and sometimes 48 h after injection using a rotating dual head scintillation camera. All 23 primary tumors and local recurrences except one were clearly visualized on at least two sections of different tomographic planes. Interestingly, nine of these patients had almost normal circulating CEA levels, and three of the visualized tumors weighed only 3-5 g. Among 19 known metastatic tumor involvements, 14 were correctly localized by ECT. Two additional liver and several bone metastases were discovered by immunoscintigraphy. Altogether, 86% of the tumor sites were detected, 82% with F(ab')2 and 89% with Fab fragments. The contrast of the tumor images obtained with Fab fragments suggests that this improved method of immunoscintigraphy has the potential to detect early tumor recurrences and thus to increase the survival of patients. The results of this retrospective study, however, should be confirmed in a prospective study before this method can be recommended for the routine diagnosis of cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS: Eight healthy volunteers (mean age 29 years) and eight patients (mean age 53 years) were investigated on a 1.5 Tesla MR system (ACS-NT, Philips, Best, The Netherlands). Renal MRA was performed using three navigator-gated free-breathing cardiac-triggered 3D SSFP sequences [repetition time (TR) = 4.4 ms, echo time (TE) = 2.2 ms, flip angle 85 degrees, spatial resolution 1.25 x 1.25 x 4.0 mm(3), scanning time approximately 1 minute 30 seconds]. The same sequence was performed without magnetization preparation, with a non-slab selective and a slab-selective inversion prepulse. Signal-to-noise ratio (SNR), contrast-to-noise (CNR) vessel length, and subjective image quality were compared. RESULTS: Three-dimensional SSFP imaging combined with a slab-selective inversion prepulse enabled selective and high contrast visualization of the renal arteries, including the more distal branches. Standard SSFP imaging without magnetization preparation demonstrated overlay by veins and renal parenchyma. A non-slab-selective prepulse abolished vessel visualization. CNR in SSFP with slab-selective inversion was 43.6 versus 10.6 (SSFP without magnetization preparation) and 0.4 (SSFP with non-slab-selective inversion), P < 0.008. CONCLUSION: Navigator-gated free-breathing cardiac-triggered 3D SSFP imaging combined with a slab-selective inversion prepulse is a novel, fast renal MRA technique without the need for contrast media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pooled F(ab')2 fragments of three MAbs against distinct epitopes of carcinoembryonic antigen (CEA) were used for radioimmunotherapy of nude mice bearing a subcutaneous human colon carcinoma xenograft. 9-10 d after transplantation when tumor nodules were in exponential growth, 36 mice were treated by intravenous injection of different amounts of 131I-labeled MAb F(ab')2. All 14 mice injected with a single dose of 2,200 (n = 10) or 2,800 microCi (n = 4) showed complete tumor remission. 8 of the 10 mice treated with 2,200 microCi survived in good health for 1 yr when they were killed and shown to be tumor free. Four of nine other mice treated with four fractionated doses of 400 microCi showed no tumor relapse for more than 9 mo. In contrast, all 15 mice injected with 1,600-3,000 microCi 131I-control IgG F(ab')2 showed tumor growth retardation of only 1-4 wk, and 15 of 16 mice injected with unlabeled anti-CEA MAb F(ab')2 showed unmodified tumor progression as compared with untreated mice. From tissue radioactivity distributions it was calculated that by an injection of 2,200 microCi 131I-MAb F(ab')2 a mean dose of 8,335 rad was selectively delivered to the tumor, while the tissue-absorbed radiation doses for the normal organs were: peripheral blood, 2,093; stomach, 1,668; kidney, 1,289; lung, 1,185; liver, 617; spleen, 501; small intestine, 427; large intestine, 367; bone, 337; and muscle, 198. These treatments were well tolerated since out of 19 mice with complete tumor remission only 4 required bone marrow transplantation and 17 were in good health for 6-12 mo of observation. The results demonstrate the selective destruction of established human colon carcinoma transplants by intravenous injection of either single or fractionated doses of 131I-MAb F(ab')2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of BK polyomavirus (BK virus, BKV) in kidney tissue is hampered by nonspecificity of antibodies suited to immunohistochemistry, and nonspecific background with in situ hybridization. The biotin-labeled DNA probe that is commercially available (Enzo Life Sciences, Inc.) shows good signal, but the intrinsic background in kidney tissue is high. We determined that the intrinsic background is due to endogenous biotin or biotin-binding activity in the renal tubular epithelium. Neither antibody blocking procedures nor an avidin/biotin block were entirely satisfactory for eliminating this background staining. We developed a digoxigenin-labeled DNA probe, and protocol, for detecting BK virus in formalin-fixed, paraffin embedded, kidney tissue obtained at autopsy. The hybridization signal is strong and there is no perceptible background staining. Eleven negative control kidneys all failed to hybridize. Conditions for low stringency hybridization may be employed, detecting both the related JC polyomavirus and BKV. Alternatively, high stringency hybridization conditions may be utilized, detecting BKV only. BK associated tubular necrosis is clearly demonstrated in two cases of BK nephritis.