173 resultados para Antiseptic-impregnated Catheter
Resumo:
Multiple organization indices have been used to predict the outcome of stepwise catheter ablation in long-standing persistent atrial fibrillation (AF), however with limited success. Our study aims at developinginnovative organization indices from baseline ECG (i.e. during the procedure, before ablation) in orderto identify the site of AF termination by catheter ablation. Seventeen consecutive male patients (age60 ± 5 years, AF duration 7 ± 5 years) underwent a stepwise catheter ablation. Chest lead V6 was placedin the back (V6b). QRST cancelation was performed from chest leads V1 to V6b. Using an innovativeadaptive harmonic frequency tracking, two measures of AF organization were computed to quantify theharmonics components of ECG activity: (1) the adaptive phase difference variance (APD) between theAF harmonic components as a measure of AF regularity, and (2) and adaptive organization index (AOI)evaluating the cyclicity of the AF oscillations. Both adaptive indices were compared to indices computedusing a time-invariant approach: (1) ECG AF cycle length (AFCL), (2) the spectrum based organizationindex (OI), and (3) the time-invariant phase difference TIPD. Long-standing persistent AF was terminatedinto sinus rhythm or atrial tachycardia in 13/17 patients during stepwise ablation, 11 during left atriumablation (left terminated patients - LT), 2 during the right atrium ablation (right terminated patients -RT), and 4 were non terminated (NT) and required electrical cardioversion. Our findings showed that LTpatients were best separated from RT/NT before ablation by the duration of sustained AF and by AOI onchest lead V1 and APD from the dorsal lead V6b as compared to ECG AFCL, OI and TIPD, respectively. Ourresults suggest that adaptive measures of AF organization computed before ablation perform better thantime-invariant based indices for identifying patients whose AF will terminate during ablation within theleft atrium. These findings are indicative of a higher baseline organization in these patients that could beused to select candidates for the termination of AF by stepwise catheter ablation.© 2013 Elsevier Ltd. All rights reserved.
Resumo:
BACKGROUND: Exposure to urinary catheters is considered the most important risk factor for healthcare-associated urinary tract infection (UTI) and is associated with significant morbidity and substantial extra-costs. In this study, we assessed the impact of urinary catheterisation (UC) on symptomatic healthcare-associated UTI among hospitalized patients. METHODS: A nationwide period prevalence survey of healthcare-associated infections was conducted during 1 May to 30 June 2004 in 49 Swiss hospitals and included 8169 adult patients (4313 female; 52.8%) hospitalised in medical, surgical, intermediate, and intensive care wards. Additional data were collected on exposure to UC to investigate factors associated with UTI among hospitalised adult patients exposed and non-exposed to UC. RESULTS: 1917 (23.5%) patients were exposed to UC within the week prior to survey day; 126 (126/8169; 1.5%) developed UTI. Exposure to UC preceded UTI only in 73 cases (58%). By multivariate logistic regression analysis, UTI was independently associated with exposure to UC (odds ratio [OR], 3.9 [95% CI, 2.6-5.9]), female gender (OR, 2.1 [95% CI, 1.4-3.1]), an American Society of Anesthesiologists' score > 2 points (OR, 3.2 [95% CI, 1.1-9.4], and prolonged hospital stay >20 days (OR, 1.9 [95% CI, 1.4-3.2]. Further analysis showed that the only significant factor for UTI with exposure to UC use was prolonged hospital stay >40 days (OR, 2.9 [95% CI, 1.3-6.1], while female gender only showed a tendency (OR, 1.6 [95% CI, 1.0-2.7]. In the absence of exposure to UC, the only significant risk factor for UTI was female gender (OR, 3.3 [95% CI, 1.7-6.5]). CONCLUSIONS: Exposure to UC was the most important risk factor for symptomatic healthcare-associated UTI, but only concerned about half of all patients with UTI. Further investigation is warranted to improve overall infection control strategies for UTI.
Resumo:
Purpose Multiple organization indices (OIs) have been used to predict the outcome of stepwise catheter ablation (step-CA) in long-standing persistent AF (pers-AF), however with limited success. Our study aims at developing innovative OIs from baseline (BL, before ablation) ECG in order to predict the outcome of step-CA. Methods Fourteen consecutive patients (pts) (60±5 y, AF duration 21±9 m) underwent a step-CA consisting in pulmonary veins isolation, left atrial (LA) defragmentation and linear ablations, and right atrial (RA) ablations if non terminated. Chest lead V6 was placed in the back (V6b). After QRST cancellation from chest leads V1 to V6b, two OIs were computed to quantify the harmonic components of ECG atrial activity: 1) phase difference variance (PD) between the AF harmonic components as a measure of AF regularity, and 2) adaptive OI (AOI) evaluating the time evolution of the AF harmonic components. Both indices were compared to classical ones: a spectrum-based OI (SOI) and ECG AF cycle length (AFCL). Results Pers-AF was terminated into sinus rhythm or atrial tachycardia in 10/14 pts during step-CA, 8 during LA (LT), 2 during RA (RT) ablation, and 4 were non terminated (NT). The figure shows that LT was best separated from RT/NT before ablation by AOI computed on lead V1 (A) and PD from lead V6b (B) as compared to SOI and AFCL respectively. Conclusion Our results suggest that adaptive OIs computed before ablation perform better than classical OIs for separating LT from RT/NT pts. These findings are indicative of a higher baseline organization in LT pts that could be used to select candidates for the restoration of sinus rhythm by step-CA.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Les infections liées aux accès vasculaires sont à l'origine d'une proportion importante des infections nosocomiales. Elles comprennent leur colonisation par des micro-organismes, les infections du site d'insertion et les bactériémies et fongémies qui leur sont associées ou attribuées. Une bactériémie complique l'insertion de 3 à 5 % des voies veineuses, correspondant à une incidence de 2 à 14 épisodes pour 1000 jourcathéters. Cette proportion ne représente toutefois que la partie visible de l'iceberg puisque la plupart des épisodes de sepsis clinique sans foyer infectieux associé sont également considérés comme liés aux accès vasculaires. Après un rappel de leur physiopathologie, cet article passe en revue les éléments importants pour leur prévention, y compris ceux concernant l'utilisation de cathéters imprégnés de désinfectants ou d'antibiotiques. Pour terminer, nous discutons en détail les stratégies préventives globales. Fondées sur la prise en compte d'un ensemble d'éléments spécifiques, ces approches sont centrées sur l'éducation du personnel au respect des règles d'hygiène de base et sur l'introduction de recommandations précises pour l'insertion et l'utilisation des accès vasculaires.
Resumo:
Alteplase has been shown to be effective in preventing central venous access clotting in patients on hemodialysis. Because of a high phosphorus content in its excipient, it can inadvertently contaminate blood samples, leading the physician in care of the patient to erroneously increase dialysis time or change diet in order to control the pseudo-hyperphosphatemia.
Resumo:
This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.
Resumo:
Les infections liées aux accès vasculaires sont l'une des causes principales des infections nosocomiales. Elles englobent leur colonisation par des micro-organismes, les infections du site d'insertion et les bactériémies et fongémies qui leur sont attribuées. Une bactériémie complique en moyenne 3 à 5 voies veineuses sur 100, ou représente de 2 à 14 épisodes pour 1000 jour-cathéters. Cette proportion n'est que la partie visible de l'iceberg puisque la plupart des épisodes de sepsis clinique sans foyer infectieux apparent associé sont actuellement considérés comme secondaires aux accès vasculaires. Les principes thérapeutiques sont présentés après une brève revue de leur physiopathologie. Plusieurs approches préventives sont ensuite discutées, y compris des éléments récents sur l'utilisation de cathéters imprégnés de désinfectants ou d'antibiotiques.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.
Resumo:
BACKGROUND: The risk of catheter-related infection or bacteremia, with initial and extended use of femoral versus nonfemoral sites for double-lumen vascular catheters (DLVCs) during continuous renal replacement therapy (CRRT), is unclear. STUDY DESIGN: Retrospective observational cohort study. SETTING & PARTICIPANTS: Critically ill patients on CRRT in a combined intensive care unit of a tertiary institution. FACTOR: Femoral versus nonfemoral venous DLVC placement. OUTCOMES: Catheter-related colonization (CRCOL) and bloodstream infection (CRBSI). MEASUREMENTS: CRCOL/CRBSI rates expressed per 1,000 catheter-days. RESULTS: We studied 458 patients (median age, 65 years; 60% males) and 647 DLVCs. Of 405 single-site only DLVC users, 82% versus 18% received exclusively 419 femoral versus 82 jugular or subclavian DLVCs, respectively. The corresponding DLVC indwelling duration was 6±4 versus 7±5 days (P=0.03). Corresponding CRCOL and CRBSI rates (per 1,000 catheter-days) were 9.7 versus 8.8 events (P=0.8) and 1.2 versus 3.5 events (P=0.3), respectively. Overall, 96 patients with extended CRRT received femoral-site insertion first with subsequent site change, including 53 femoral guidewire exchanges, 53 new femoral venipunctures, and 47 new jugular/subclavian sites. CRCOL and CRBSI rates were similar for all such approaches (P=0.7 and P=0.9, respectively). On multivariate analysis, CRCOL risk was higher in patients older than 65 years and weighing >90kg (ORs of 2.1 and 2.2, respectively; P<0.05). This association between higher weight and greater CRCOL risk was significant for femoral DLVCs, but not for nonfemoral sites. Other covariates, including initial or specific DLVC site, guidewire exchange versus new venipuncture, and primary versus secondary DLVC placement, did not significantly affect CRCOL rates. LIMITATIONS: Nonrandomized retrospective design and single-center evaluation. CONCLUSIONS: CRCOL and CRBSI rates in patients on CRRT are low and not influenced significantly by initial or serial femoral catheterizations with guidewire exchange or new venipuncture. CRCOL risk is higher in older and heavier patients, the latter especially so with femoral sites.
Resumo:
Catheter-related infection remains a leading cause of nosocomial infections, particularly in intensive care units. It includes colonization of the device, skin exit-site infection and device- or catheter-related bloodstream infection. The latter represents the most frequent life-threatening associated complication of central venous catheter use and is associated with significant patient morbidity, mortality and extra hospital costs. The incidence of catheter-related bloodstream infection ranges from 2 to 14 episodes per 1000 catheter-days. On average, microbiologically-documented device-related bloodstream infections complicate from three to five per 100 central venous line uses, but they only represent the visible part of the iceberg and most clinical sepsis are nowadays considered to be catheter-related. We briefly review the pathophysiology of infection, highlighting the importance of the skin insertion site and of intravenous line hub as principal sources of colonization. Principles of therapy are reviewed. Several preventive approaches are also discussed, in particular the possible benefit of recently developed impregnated catheters. Finally, the potential positive impact of a multimodal global preventive strategy based on strict application of hygienic rules is presented.
Resumo:
PURPOSE OF REVIEW: The safety and efficiency of trans catheter aortic valve implantation (TAVI) has been clearly demonstrated. In high-risk patients, the number of procedures is constantly increasing and in western European countries this procedure is employed in more than 30% of isolated aortic valve replacements. The literature, however, focusing on perioperative aortic root (AoR) rupture is rather limited to just a few reports. The aim of this review is to analyze the pathophysiology of AoR rupture during TAVI, stressing the implications of the morphology of the AoR for this devastating complication. RECENT FINDINGS: Currently, perioperative AoR rupture ranges between 0.5 and 1.5% during TAVI, with almost 100% mortality. Recently, valve oversizing and balloon dilatation in a calcified and small AoR were considered as the most important predictive factors for this complication. SUMMARY: The most fragile unit of the AoR is its anchoring substrate to the ostium of the left ventricle. This membranous structure is not involved in the degenerative process leading to aortic valve stenosis. Due to the TAVI and/or balloon dilatation of the calcium stationed on the three leaflets and their attachment, a lesion may result on this structure. And, as a consequence, there is rupture of the AoR.