100 resultados para SELF-EXPANDABLE METALLIC STENT
Resumo:
In the last few years, there has been a growing focus on faster computational methods to support clinicians in planning stenting procedures. This study investigates the possibility of introducing computational approximations in modelling stent deployment in aneurysmatic cerebral vessels to achieve simulations compatible with the constraints of real clinical workflows. The release of a self-expandable stent in a simplified aneurysmatic vessel was modelled in four different initial positions. Six progressively simplified modelling approaches (based on Finite Element method and Fast Virtual Stenting – FVS) have been used. Comparing accuracy of the results, the final configuration of the stent is more affected by neglecting mechanical properties of materials (FVS) than by adopting 1D instead of 3D stent models. Nevertheless, the differencesshowed are acceptable compared to those achieved by considering different stent initial positions. Regarding computationalcosts, simulations involving 1D stent features are the only ones feasible in clinical context.
Resumo:
Acute variceal bleeding (AVB) is a life-threatening complication in patients with cirrhosis. Hemostatic therapy of AVB includes early administration of vasoactive drugs that should be combined with endoscopic therapy, preferably banding ligation. However, failure to control bleeding or early rebleed within 5 days still occurs in 15-20% of patients with AVB. In these cases, a second endoscopic therapy may be attempted (mild bleeding in a hemodynamically stable patient) or we can use a balloon tamponade as a bridge to definitive derivative treatment (i.e., a transjugular intrahepatic portosystemic shunt). Esophageal balloon tamponade provides initial control in up to 80% of AVB, but it carries a high risk of major complications, especially in cases of long duration of tamponade (>24 h) and when tubes are inserted by inexperienced staff. Preliminary reports suggest that self-expandable covered esophageal metallic stents effectively control refractory AVB (i.e., ongoing bleeding despite pharmacological and endoscopic therapy or massive bleeding precluding endoscopic therapy) with a low incidence of complications. Thus, covered self-expanding metal stents may represent an alternative to the Sengstaken-Blakemore balloon for the temporary control of bleeding in treatment failures. Further studies are required to determine the role of this new device in AVB.
Resumo:
Step bunching develops in the epitaxy of SrRuO3 on vicinal SrTiO3(001) substrates. We have investigated the formation mechanisms and we show here that step bunching forms by lateral coalescence of wedgelike three-dimensional islands that are nucleated at substrate steps. After coalescence, wedgelike islands become wider and straighter with growth, forming a self-organized network of parallel step bunches with altitudes exceeding 30 unit cells, separated by atomically flat terraces. The formation mechanism of step bunching in SrRuO3, from nucleated islands, radically differs from one-dimensional models used to describe bunching in semiconducting materials. These results illustrate that growth phenomena of complex oxides can be dramatically different to those in semiconducting or metallic systems.
Resumo:
We report a systematic study of the low-temperature electrical conductivity in a series of SrRuO3 epitaxial thin films. At relatively high temperature the films display the conventional metallic behavior. However, a well-defined resistivity minimum appears at low temperature. This temperature dependence can be well described in a weak localization scenario: the resistivity minimum arising from the competition of electronic self-interference effects and the normal metallic character. By appropriate selection of the film growth conditions, we have been able to modify the mean-free path of itinerant carriers and thus to tune the relative strength of the quantum effects. We show that data can be quantitatively described by available theoretical models.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
Durant els darrers anys, s’han publicat un gran nombre de materials multimèdia destinats a l’aprenentatge de llengües, la major part dels quals son CD-ROM dissenyats com a cursos per l’autoaprenentatge. Amb aquests materials, els alumnes poden treballar independentment sense l’assessorament d’un professor, i per aquest motiu s’ha afirmat que promouen i faciliten l’aprenentatge autònom. Aquesta relació, però, no es certa, com Phil Benson i Peter Voller 1997:10) han manifestat encertadament:(…) Such claims are often dubious, however, because of the limited range of options and roles offered to the learner. Nevertheless, technologies of education in the broadest sense can be considered to be either more or less supportive of autonomy. The question is what kind of criteria do we apply in evaluating them? En aquest article presentem una investigació conjunta on es defineixen els criteris que poden ser utilitzats per avaluar materials multimèdia en relació a la seva facilitat per permetre l’aprenentatge autònom. Aquests criteris son la base d’un qüestionari que s’ha emprat per avaluar una selecció de CD-ROM destinats a l’autoaprenentatge de llengües. La estructura d’aquest article és la següent: - Una introducció de l’estudi - Els criteris que s’han utilitzar per la creació del qüestionari - Els resultats generals de l’avaluació - Les conclusions que s’han extret i la seva importància pel disseny instructiu multimèdia
Resumo:
Són molts els estudis que avui en dia incideixen en la necessitat d’oferir un suport metodològic i psicològic als aprenents que treballen de manera autònoma. L’objectiu d’aquest suport és ajudar-los a desenvolupar les destreses que necessiten per dirigir el seu aprenentatge així com una actitud positiva i una major conscienciació envers aquest aprenentatge. En definitiva, aquests dos tipus de preparació es consideren essencials per ajudar els aprenents a esdevenir més autònoms i més eficients en el seu propi aprenentatge. Malgrat això, si bé és freqüent trobar estudis que exemplifiquen aplicacions del suport metodològic dins els seus programes, principalment en la formació d’estratègies o ajudant els aprenents a desenvolupar un pla de treball, aquest no és el cas quan es tracta de la seva preparació psicològica. Amb rares excepcions, trobem estudis que documentin com s’incideix en les actituds i en les creences dels aprenents, també coneguts com a coneixement metacognitiu (CM), en programes que fomenten l’autonomia en l’aprenentatge. Els objectius d’aquest treball son dos: a) oferir una revisió d’estudis que han utilitzat diferents mitjans per incidir en el CM dels aprenents i b) descriure les febleses i avantatges dels procediments i instruments que utilitzen, tal com han estat valorats en estudis de recerca, ja que ens permetrà establir criteris objectius sobre com i quan utilitzar-los en programes que fomentin l’aprenentatge autodirigit.
Resumo:
Vegeu el resum a l'inici del document del fitxer adjunt
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
Constitutional arrangements affect the decisions made by a society. We study how this effect leads to preferences of citizens over constitutions; and ultimately how this has a feedback that determines which constitutions can survive in a given society. Constitutions are stylized here, to consist of a voting rule for ordinary business and possibly different voting rule for making changes to the constitution. We deffine an equilibrium notion for constitutions, called self-stability, whereby under the rules of a self-stable constitution, the society would not vote to change the constitution. We argue that only self-stable constitutions will endure. We prove that self-stable constitutions always exist, but that most constitutions (even very prominent ones) may not be self-stable for some societies. We show that constitutions where the voting rule used to amend the constitution is the same as the voting rule used for ordinary business are dangerously simplistic, and there are (many) societies for which no such constitution is self-stable rule. We conclude with a characterization of the set of self-stable constitutions that use majority rule for ordinary business.
Resumo:
This paper studies collective choice rules whose outcomes consist of a collection of simultaneous decisions, each one of which is the only concern of some group of individuals in society. The need for such rules arises in different contexts, including the establishment of jurisdictions, the location of multiple public facilities, or the election of representative committees. We define a notion of allocation consistency requiring that each partial aspect of the global decision taken by society as a whole should be ratified by the group of agents who are directly concerned with this particular aspect. We investigate the possibility of designing envy-free allocation consistent rules, we also explore whether such rules may also respect the Condorcet criterion.
Resumo:
One of the most persistent and lasting debates in economic research refers to whether the answers to subjective questions can be used to explain individuals’ economic behavior. Using panel data for twelve EU countries, in the present study we analyze the causal relationship between self-reported housing satisfaction and residential mobility. Our results indicate that: i) households unsatisfied with their current housing situation are more likely to move; ii) housing satisfaction raises after a move, and; iii) housing satisfaction increases with the transition from being a renter to becoming a homeowner. Some interesting cross-country differences are observed. Our findings provide evidence in favor of use of subjective indicators of satisfaction with certain life domains in the analysis of individuals’ economic conduct.
Resumo:
It has been recently found that a number of systems displaying crackling noise also show a remarkable behavior regarding the temporal occurrence of successive events versus their size: a scaling law for the probability distributions of waiting times as a function of a minimum size is fulfilled, signaling the existence on those systems of self-similarity in time-size. This property is also present in some non-crackling systems. Here, the uncommon character of the scaling law is illustrated with simple marked renewal processes, built by definition with no correlations. Whereas processes with a finite mean waiting time do not fulfill a scaling law in general and tend towards a Poisson process in the limit of very high sizes, processes without a finite mean tend to another class of distributions, characterized by double power-law waiting-time densities. This is somehow reminiscent of the generalized central limit theorem. A model with short-range correlations is not able to escape from the attraction of those limit distributions. A discussion on open problems in the modeling of these properties is provided.